Limitations of forehead pulse oximetry

During initial clinical tests to calibrate our reflectance pulse oximetry system, we observed serious physiologic limitations to the use of pulse oximetry in the forehead region. We present a case of simultaneous reflectance and transmission mode pulse oximetry monitoring in a child undergoing cardiac surgery for congenital cyanotic heart disease with a large intracardiac shunt. During general anesthesia, when the patient was endotracheally intubated and mechanically ventilated, the transmission mode saturation agreed well with arterial oxygen saturation measurements; but, our reflectance pulse oximeter, with the sensor applied to the forehead, displayed spuriously lower (−18%) oxygen saturations. Before and after anesthesia and surgery, there was fine agreement between reflectance and transmission mode saturation values. We suggest that the difference was caused by vasodilatation and pooling of venous blood due to compromised venous return to the heart, and a combination of arterial and venous pulsations in the forehead region. This means that the reflectance pulse oximeter measured a mixed arterial-venous oxygen saturation.

[1]  Setsuo Takatani,et al.  Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor , 1992, Journal of Clinical Monitoring.

[2]  D. A. Davis,et al.  Falsely normal saturation reading with the pulse oximeter. , 1987, Anesthesiology.

[3]  Vassyl A. Lonchyna,et al.  Central venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry , 2005, Journal of Clinical Monitoring.

[4]  K. Arakawa,et al.  Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography , 1986, Anesthesia and analgesia.

[5]  Y Mendelson,et al.  Noninvasive measurement of arterial oxyhemoglobin saturation with a heated and a non-heated skin reflectance pulse oximeter sensor. , 1991, Biomedical instrumentation & technology.

[6]  Volker König,et al.  Reflexions-Pulsoximetrie - Untersuchungen mit eigenem Mess-System , 1992 .

[7]  K. Tremper,et al.  Pulse oximetry. , 1989, Anesthesiology.

[8]  J. Severinghaus,et al.  Recent Developments in Pulse Oximetry , 1992, Anesthesiology.

[9]  J. Gardosi,et al.  Adaptation of pulse oximetry for fetal monitoring during labour , 1991, The Lancet.

[10]  M. Abu-Yousef Normal and respiratory variations of the hepatic and portal venous duplex Doppler waveforms with simultaneous electrocardiographic correlation , 1992, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[11]  C. Reilly,et al.  An evaluation of the effect of vasodilatation on oxygen saturations measured by pulse oximetry and venous blood gas analysis , 1993, Anaesthesia.