A mobile force plate system and its application to quantitative evaluation of normal and pathological gait

In clinical applications, the quantitative analysis of gait variability using kinematic and kinetic characterizations can be helpful to medical doctors in monitoring patient recovery status. A high-speed camera system and a stationary force plate can only accurately measure complete ground reaction force (GRF) and body orientations during a few steps, but data on successive gait measurements including three-dimensional (3D) force and motion in different environments is really desired by clinical researchers and doctors. We have developed a mobile force plate and 3D motion analysis system (M3D) by integrating small triaxial force sensors and 3D inertial sensors for estimating multi-axial GRF and orientations of feet during successive gait movements. In order to verify the measurements of the developed system, we used a stationary force plate as a reference measurement system to simultaneously measure the triaxial GRF and center of pressure (CoP) when a subject was required to wear the M3D. Static and dynamic test experiments were implemented to validate the triaxial force measurement of the M3D. Experimental results verify that the developed system can be used to measure the triaxial force with acceptable precision (error: less than 6.4% of maximum measurement force). An application trial was carried out to analyze normal gait and paralysis gait using the M3D. Quantitative differences between gaits were analyzed, based on the results of the vertical component of GRF and medial-lateral directional angular flexions of the feet.

[1]  Li-I Wang,et al.  The kinetics and stiffness characteristics of the lower extremity in older adults during vertical jumping. , 2008, Journal of sports science & medicine.

[2]  Abhishek Srivastava,et al.  Post-stroke balance training: Role of force platform with visual feedback technique , 2009, Journal of the Neurological Sciences.

[3]  J. Perry,et al.  Gait Analysis , 2024 .

[4]  L. Chou,et al.  Detection of gait instability using the center of mass and center of pressure inclination angles. , 2006, Archives of physical medicine and rehabilitation.

[5]  J. Bortz A New Mathematical Formulation for Strapdown Inertial Navigation , 1971, IEEE Transactions on Aerospace and Electronic Systems.

[6]  Tao Liu,et al.  A Small and Low-Cost 3-D Tactile Sensor for a Wearable Force Plate , 2009, IEEE Sensors Journal.

[7]  John C. Rothwell,et al.  Effectiveness of a community-based low intensity exercise programme for ambulatory stroke survivors , 2010, Disability and rehabilitation.

[8]  Marcus G Pandy,et al.  Simultaneous prediction of muscle and contact forces in the knee during gait. , 2010, Journal of biomechanics.

[9]  Can A Yucesoy,et al.  Effects of back loading on the biomechanics of sit-to-stand motion in healthy children. , 2008, Human movement science.

[10]  Benjamin J. Fregly,et al.  Simultaneous Prediction of Muscle and Contact Forces in the Knee During Gait , 2009 .

[11]  Zhaoying Zhou,et al.  A Small Low-Cost Hybrid Orientation System and Its Error Analysis , 2009 .

[12]  Christopher S. Pan,et al.  Analysis of Musculoskeletal Loadings in Lower Limbs During Stilts Walking in Occupational Activity , 2009, Annals of Biomedical Engineering.

[13]  Jean-Marie Denoix,et al.  Design and validation of a dynamometric horseshoe for the measurement of three-dimensional ground reaction force on a moving horse. , 2009, Journal of biomechanics.

[14]  Tao Liu,et al.  Development of a wearable sensor system for quantitative gait analysis , 2009 .

[15]  P. Veltink,et al.  Ambulatory measurement of ground reaction forces , 2005 .

[16]  Mark S. Redfern,et al.  Measuring Slipperiness : Human Locomotion and Surface Factors , 2002 .

[17]  P. Veltink,et al.  Evaluation of instrumented shoes for ambulatory assessment of ground reaction forces. , 2007, Gait & posture.

[18]  Alfred D. Grant Gait Analysis: Normal and Pathological Function , 2010 .

[19]  Tao Liu,et al.  Wearable force sensor with parallel structure for measurement of ground-reaction force , 2007 .

[20]  Peter H. Veltink,et al.  Ambulatory Assessment of Ankle and Foot Dynamics , 2007, IEEE Transactions on Biomedical Engineering.