Ammonia Emissions from USA Broiler Chicken Barns Managed with New Bedding, Built-up Litter, or Acid-Treated Litter

Poultry producers in the United States have attempted to maintain barn aerial ammonia (NH3) levels below 25 ppm to improve air quality, and more recently to decrease aerial emissions to the atmosphere. Our objective was to investigate the influence of litter management strategies on NH3 emissions from commercial broiler barns employing new bedding, acid-treated built-up litter (sodium bisulphate), or untreated built-up litter (normal practice). Nearly 400 barn-days of NH3 emissions data were collected from 12 broiler barns on four farms monitored in 48-hour episodes over one year. On each study farm, the barns were paired for repetition of conditions. Emission was calculated as the product of gas concentration of the exhaust air and barn ventilation rate. Use of new bedding for every flock led to consistently lower NH3 emission (averaging 0.35 g NH3/(bird d)) at day 21 of the 42-day flock grow-outs, followed by flocks raised on the annual cleanout with new bedding (0.52 g NH3/(bird d)). Built-up litter without any treatment had the highest emission (0.73 g NH3/(bird d)), followed by the built-up litter with acid treatment (0.63 g NH3/(bird d)). One study site was managed with two barns using litter treatment and two identical barns with untreated, built-up litter for a side-by-side comparison of results under field conditions. Ammonia emissions from treated built-up litter barns were similar to those from untreated built-up litter barns, however, the temporal pattern of emissions provided evidence that ammonia held in the acid-treated litter at the beginning of the flock was released during the latter period of the flock cycle.

[1]  Richard S Gates,et al.  A Portable System for Continuous Ammonia Measurement in the Field , 2002 .

[2]  V. R. Phillips,et al.  A review of methods for measuring emission rates of ammonia from livestock buildings and slurry or manure stores, part 1: assessment of basic approaches. , 2000 .

[3]  Hongwei Xin,et al.  Field Estimation of Ventilation Capacity Using FANS , 2002 .

[4]  Hongwei Xin,et al.  U.S. broiler housing ammonia emissions inventory , 2008 .

[5]  Hongwei Xin,et al.  On-Farm Ventilation Fan Performance Evaluations and Implications , 2008 .

[6]  C. Copeland Air Quality Issues and Animal Agriculture: EPA's Air Compliance Agreement [July 20, 2012] , 2008 .

[7]  Hongwei Xin,et al.  Method for Measuring Ammonia Emissions from Poultry Houses , 2005 .

[8]  Albert J. Heber,et al.  Sampling and Measurement of Ammonia Concentration at Animal Facilities - A Review , 2001 .

[9]  Richard S Gates,et al.  AMMONIA EMISSIONS FROM U.S. POULTRY HOUSES: PART I – MEASUREMENT SYSTEM AND TECHNIQUES , 2003 .

[10]  Hongwei Xin,et al.  Ammonia Emissions from Twelve U.S. Broiler Chicken Houses , 2006 .

[11]  Lara B. Moody,et al.  Ammonia Emissions from Broiler Houses in the Southeastern United States , 2007 .

[12]  Calvin B. Parnell,et al.  PARTICULATE MATTER AND AMMONIA EMISSION FACTORS FOR TUNNEL–VENTILATED BROILER PRODUCTION HOUSES IN THE SOUTHERN U.S. , 2003 .

[13]  John D. Simmons,et al.  Fan Assessment Numeration System (FANS) Design and Calibration Specifications , 2002 .

[14]  T. C. Daniel,et al.  Evaluation of chemical amendments to reduce ammonia volatilization from poultry litter. , 1996, Poultry science.

[15]  R. Siefert,et al.  Characterization of atmospheric ammonia emissions from a commercial chicken house on the Delmarva Peninsula. , 2004, Environmental science & technology.