The Qnde Using Image Processing of the Magnetic Camera
暂无分享,去创建一个
A scan type magnetic camera was proposed to satisfy the following demands: to obtain high speed quantitative magnetic flux leakage (MFL) distribution with homogeneous lift-off by using 2-dimensionally arrayed high sensitivity magnetic sensors; to concentrate the MFL; and to ignore the residual magnetization and magnetic hysteresis by using a magnetic fluid lens. The magnetic field distribution (MFD) image obtained by using the scan type magnetic camera is inclined to the scanning direction (x-direction) because of the poles of the magnetizer. Also, the image shows a homogeneous trend relative to the x-direction, but there are small waves in the distribution in the sensor arraying direction (y-direction). The crack information in the MFD image can be extracted using image processing. The first and second derivatives of both x and y are used in this processing. These are "1st derivative of x, ∂B/∂x", "1st derivative of y, ∂B/∂y", "2nd derivative of x, ∂2B/∂x2", "2nd derivative of y, ∂2B/∂y2", and "2nd derivative of x and y, ∂2B/∂x∂y". The ∂B/∂x distribution shows the existence of the crack. Also, the crack volume can be evaluated quantitatively, regardless of the crack direction, by using ∂B/∂x and a cross type magnetic coil.
[1] Jae Kyoo Lim,et al. Detection Probability Improvement for Nondestructive Evaluation Using a Magnetic Camera , 2006 .
[2] Tetsuo Shoji,et al. Numerical Consideration of Magnetic Camera for Quantitative Nondestructive Evaluation , 2004 .
[3] Jin Yi Lee,et al. A Study of Leakage Magnetic Flux Detector Using Hall Sensors Array , 2006 .