Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging.

Magnetic resonance imaging (MRI) thermometry has been utilized for in vivo evaluation of thermal exposure induced by a focused ultrasound beam. A simulation study of the focused ultrasound beam was conducted to select imaging parameters for reducing the error due to the spatial and temporal averaging of MRI. Temperature imaging based on the proton resonance frequency shift was utilized to obtain the temperature distribution during sonication in the skeletal muscle of eight rabbits. MRI-derived temperature information was then used to calculate the thermal dose distribution induced by the sonication and to estimate the coagulated tissue volume. The tissue changes were also evaluated directly by taking the T2-weighted and the contrast agent enhanced T1-weighted MR images. Errors in the temperature and thermal dose measurements were found to be minimal using the following parameters: slice thickness = 3 mm, voxel dimension = 0.6 mm, and scan time per image = 3.4 s. The estimated dimensions of the coagulated tissue volume were in good agreement with the tissue damages seen on the contrast agent enhanced T1-weighted images. The tissue damage seen on the histology was closely matched to the ones seen on the T2-weighted images. This study showed that MRI thermometry has significant potential for both monitoring the thermal exposure and evaluating the tissue damage. This would allow real-time control of the sonication parameters to optimize clinical treatments.

[1]  C. J. Martin,et al.  Design of thermistor probes for measurement of ultrasound intensity distributions , 1983 .

[2]  D L Parker,et al.  Temperature distribution measurements in two-dimensional NMR imaging. , 1983, Medical physics.

[3]  R M Henkelman,et al.  Ex vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry , 1998, Magnetic resonance in medicine.

[4]  K. Hynynen,et al.  Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam , 1996, Magnetic resonance in medicine.

[5]  S D Prionas,et al.  The effects of hyperthermia on normal mesenchymal tissues. Application of a histologic grading system. , 1983, Archives of pathology & laboratory medicine.

[6]  K. Hynynen The threshold for thermally significant cavitation in dog's thigh muscle in vivo. , 1991, Ultrasound in medicine & biology.

[7]  F A Jolesz,et al.  Real‐time magnetic resonance imaging of laser heat deposition in tissue , 1991, Magnetic resonance in medicine.

[8]  C R Hill,et al.  Lesion development in focused ultrasound surgery: a general model. , 1994, Ultrasound in medicine & biology.

[9]  K. Hynynen,et al.  Temperature measurements during ultrasound hyperthermia. , 1989, Medical physics.

[10]  Kevin J. Parker,et al.  The thermal pulse decay technique for measuring ultrasonic absorption coefficients , 1983 .

[11]  J. Hindman,et al.  Proton Resonance Shift of Water in the Gas and Liquid States , 1966 .

[12]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[13]  F. Jolesz,et al.  Tissue temperature monitoring for thermal interventional therapy: Comparison of T1‐weighted MR sequences , 1994, Journal of magnetic resonance imaging : JMRI.

[14]  T. Cetas,et al.  Thermometry considerations in localized hyperthermia. , 1978, Medical physics.

[15]  K. Hynynen,et al.  MRI-guided noninvasive ultrasound surgery. , 1993, Medical physics.

[16]  F A Jolesz,et al.  A clinical, noninvasive, MR imaging-monitored ultrasound surgery method. , 1996, Radiographics : a review publication of the Radiological Society of North America, Inc.

[17]  K. Hynynen,et al.  Simultaneous magnetic resonance phase and magnitude temperature maps in muscle , 1996, Magnetic resonance in medicine.

[18]  Kullervo Hynynen,et al.  MR temperature mapping of focused ultrasound surgery , 1994, Magnetic resonance in medicine.

[19]  Ferenc A. Jolesz,et al.  MR-guided focused ultrasound surgery. , 1992 .

[20]  D Le Bihan,et al.  Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. , 1989, Radiology.

[21]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[22]  W. Fry,et al.  Determination of Absolute Sound Levels and Acoustic Absorption Coefficients by Thermocouple Probes—Theory , 1954 .

[23]  K. Hynynen,et al.  The effect of wave reflection and refraction at soft tissue interfaces during ultrasound hyperthermia treatments. , 1992, The Journal of the Acoustical Society of America.

[24]  P. P. Lele,et al.  Production of deep focal lesions by focused ultrasound--current status. , 1967, Ultrasonics.

[25]  F A Jolesz,et al.  Focused US system for MR imaging-guided tumor ablation. , 1995, Radiology.

[26]  R. Watkins,et al.  One‐Dimensional NMR Thermal Mapping of Focused Ultrasound Surgery , 1994, Journal of computer assisted tomography.

[27]  L P Panych,et al.  Effects related to temperature changes during MR imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[28]  A. S. Hall,et al.  Measurement of changes in tissue temperature using MR imaging. , 1986, Journal of computer assisted tomography.

[29]  K Hynynen,et al.  The Usefulness of a Contrast Agent and Gradient–Recalled Acquisition in a Steady–State Imaging Sequence for Magnetic Resonance Imaging–Guided Noninvasive Ultrasound Surgery , 1994, Investigative radiology.

[30]  K Hynynen,et al.  The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery. , 1994, The Journal of the Acoustical Society of America.

[31]  H. O'neil Theory of Focusing Radiators , 1949 .