Harmonic minimization in the operation of static VAR compensators for unbalanced reactive power compensation

Phase-wise unbalanced reactive power compensations are required in distribution systems for dynamic power factor correction and terminal voltage stabilization. Shunt compensators are generally used to reduce or cancel the phase-wise unbalanced reactive power (VAR) demand and to minimize the reactive power drawn from the AC supply lines. Static VAR compensators are preferred over traditional VAR compensators for this purpose. The operation of thyristor-controlled compensators at various conduction angles can be used advantageously to meet the unbalanced reactive power demands in a system. However such an operation introduces harmonic currents in to the AC system. In such cases it becomes necessary either to minimize harmonic generation internally or provide external harmonic filters. In this paper, an approach is presented for operation of VAR compensators for minimization of the effect of the harmonics using the telephone influence factor (TIF) and the total harmonic distortion factor (THD) for a typical distribution system.

[1]  Laszlo Gyugyi,et al.  Power electronics in electric utilities: static VAR compensators , 1988, Proc. IEEE.

[2]  M. Villablanca,et al.  Harmonic Reduction In Group-Connected Generators-HVDC Convertor , 1992, ICHPS V International Conference on Harmonics in Power Systems..

[3]  C. Surapong,et al.  Minimization of the effects of harmonics and voltage dip caused by electric arc furnace , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[4]  Laszlo Gyugyi,et al.  Characteristics of Static, Thyristor-Controlled Shunt Compensators for Power Transmission System Applications , 1980, IEEE Transactions on Power Apparatus and Systems.

[5]  S. Chirarattananon,et al.  Harmonic minimizing neural network SVC controller for compensating unbalanced fluctuating loads , 2002, 10th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.02EX630).

[6]  A. Lopez,et al.  Power-quality improvement in reactive power control using FC-TCR circuits , 2002, IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02.

[7]  L. Gyugyi,et al.  Principles and Applications of Static, Thyristor-Controlled Shunt Compensators , 1978, IEEE Transactions on Power Apparatus and Systems.

[8]  J. K. Phipps,et al.  Power quality and harmonic distortion on distribution systems , 1991, [Proceedings] 1991 Rural Electric Power Conference. Papers presented at the 35th Annual Conference.

[9]  Pat Bodger,et al.  Power System Harmonics , 2003 .

[10]  K. Parthasarathy,et al.  An algorithm for optimum control of static VAR compensators to meet phase-wise unbalanced reactive power demands , 1986 .