Accelerated real-time cardiac MRI using iterative sparse SENSE reconstruction: comparing performance in patients with sinus rhythm and atrial fibrillation

ObjectivesTo compare accelerated real-time cardiac MRI (CMR) using sparse spatial and temporal undersampling and non-linear iterative SENSE reconstruction (RT IS SENSE) with real-time CMR (RT) and segmented CMR (SEG) in a cohort that included atrial fibrillation (AF) patients.MethodsWe evaluated 27 subjects, including 11 AF patients, by acquiring steady-state free precession cine images covering the left ventricle (LV) at 1.5 T with SEG (acceleration factor 2, TR 42 ms, 1.8 × 1.8 × 6 mm3), RT (acceleration factor 3, TR 62 ms, 3.0 × 3.0 × 7 mm3), and RT IS SENSE (acceleration factor 9.9-12, TR 42 ms, 2.0 × 2.0 × 7 mm3). We performed quantitative LV functional analysis in sinus rhythm (SR) patients and qualitatively scored image quality, noise and artefact using a 5-point Likert scale in the complete cohort and AF and SR subgroups.ResultsThere was no difference between LV functional parameters between acquisitions in SR patients. RT IS SENSE short-axis image quality was superior to SEG (4.5 ± 0.6 vs. 3.9 ± 1.1, p = 0.007) and RT (3.8 ± 0.4, p = 0.003). There was reduced artefact in RT IS SENSE compared to SEG (4.4 ± 0.6 vs. 3.8 ± 1.2, p = 0.04), driven by arrhythmia performance. RT IS SENSE short-axis image quality was superior to SEG (4.6 ± 0.5 vs. 3.1 ± 1.0, p < 0.001) in the AF subgroup.ConclusionAccelerated real-time CMR with iterative sparse SENSE provides excellent clinical performance, especially in patients with AF.Key Points• Iterative sparse SENSE significantly accelerates real-time cardiovascular MRI acquisitions.• It provides excellent qualitative and quantitative performance in sinus rhythm patients.• It outperforms standard segmented acquisitions in patients with atrial fibrillation.• It improves the trade-off between temporal and spatial resolution in real-time imaging.

[1]  H. Quick,et al.  Real-time SPARSE-SENSE cardiac cine MR imaging: optimization of image reconstruction and sequence validation , 2016, European Radiology.

[2]  Pedro F Ferreira,et al.  Cardiovascular magnetic resonance artefacts , 2013, Journal of Cardiovascular Magnetic Resonance.

[3]  Jens Frahm,et al.  Magnetic resonance imaging in real time: Advances using radial FLASH , 2010, Journal of magnetic resonance imaging : JMRI.

[4]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[5]  Nicole Seiberlich,et al.  Real-time imaging with radial GRAPPA: Implementation on a heterogeneous architecture for low-latency reconstructions. , 2014, Magnetic resonance imaging.

[6]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[7]  Peter Kellman,et al.  High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions , 2013, Journal of Cardiovascular Magnetic Resonance.

[8]  Michaela Schmidt,et al.  Right ventricular assessment at cardiac MRI: initial clinical experience utilizing an IS-SENSE reconstruction , 2016, The International Journal of Cardiovascular Imaging.

[9]  F H Epstein,et al.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) † , 2001, Magnetic resonance in medicine.

[10]  Jens Frahm,et al.  Real-time cardiovascular magnetic resonance at 1.5 T using balanced SSFP and 40 ms resolution , 2013, Journal of Cardiovascular Magnetic Resonance.

[11]  C H Lorenz,et al.  Quantification of left ventricular function with magnetic resonance images acquired in real time , 2000, Journal of magnetic resonance imaging : JMRI.

[12]  Michaela Schmidt,et al.  Real-time cardiac magnetic resonance cine imaging with sparse sampling and iterative reconstruction for left-ventricular measures: Comparison with gold-standard segmented steady-state free precession. , 2017, Magnetic resonance imaging.

[13]  Peter Kellman,et al.  Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA) , 2005, Magnetic resonance in medicine.

[14]  Jens Frahm,et al.  Real-time cardiovascular magnetic resonance at high temporal resolution: radial FLASH with nonlinear inverse reconstruction , 2010, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[15]  Michaela Schmidt,et al.  Highly undersampled contrast‐enhanced MRA with iterative reconstruction: Integration in a clinical setting , 2015, Magnetic resonance in medicine.

[16]  Cengizhan Ozturk,et al.  RT‐GROG: parallelized self‐calibrating GROG for real‐time MRI , 2010, Magnetic resonance in medicine.

[17]  Edgar Mueller,et al.  Dynamic cardiac MRI reconstruction with weighted redundant Haar wavelets , 2022 .

[18]  Michaela Schmidt,et al.  Free-breathing Sparse Sampling Cine MR Imaging with Iterative Reconstruction for the Assessment of Left Ventricular Function and Mass at 3.0 T. , 2017, Radiology.

[19]  J P Ridgway,et al.  Qualitative and quantitative analysis of regional left ventricular wall dynamics using real‐time magnetic resonance imaging: Comparison with conventional breath‐hold gradient echo acquisition in volunteers and patients , 2001, Journal of magnetic resonance imaging : JMRI.

[20]  Li Feng,et al.  Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE , 2013, Magnetic resonance in medicine.

[21]  Jens Frahm,et al.  Real‐time phase‐contrast MRI of cardiovascular blood flow using undersampled radial fast low‐angle shot and nonlinear inverse reconstruction , 2012, NMR in biomedicine.

[22]  Christoph Forman,et al.  Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold , 2016, Journal of Cardiovascular Magnetic Resonance.

[23]  M. Stuber,et al.  Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass. , 2014, JACC. Cardiovascular imaging.

[24]  C. Chefd'Hotel,et al.  High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting , 2009, Magnetic resonance in medicine.

[25]  Bradley D. Allen,et al.  Highly accelerated cardiac MRI using iterative SENSE reconstruction: initial clinical experience , 2016, The International Journal of Cardiovascular Imaging.

[26]  Nicole Seiberlich,et al.  Improved radial GRAPPA calibration for real‐time free‐breathing cardiac imaging , 2011, Magnetic resonance in medicine.