Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes

A dysfunctional vestibular system can be a severe detriment to the quality of life of a patient. Recent studies have shown the feasibility for a vestibular implant to restore rotational sensation via electrical stimulation of vestibular ampullary nerves. However, the optimal stimulation site for selective elicitation of the desired nerve is still unknown. We realized a finite element model on the basis of μCT scans of a human inner ear and incorporated naturally distributed, artificial neural trajectories. A well-validated neuron model of myelinated fibers was incorporated to predict nerve responses to electrical stimulation. Several virtual electrodes were placed in locations of interest inside the bony labyrinth (intra-labyrinthine) and inside the temporal bone, near the target nerves (extra-labyrinthine), to determine preferred stimulation sites and electrode insertion depths. We investigated various monopolar and bipolar electrode configurations as well as different pulse waveform shapes for their ability to selectively stimulate the target nerve and for their energy consumption. The selectivity was evaluated with an objective measure of the fiber recruitment. Considerable differences of required energy and achievable selectivity between the configurations were observed. Bipolar, intra-labyrinthine electrodes provided the best selectivities but also consumed the highest amount of energy. Bipolar, extra-labyrinthine configurations did not offer any advantages compared to the monopolar approach. No selective stimulation could be performed with the monopolar, intra-labyrinthine approach. The monopolar, extra-labyrinthine electrodes required the least energy for satisfactory selectivities, making it the most promising approach for functional vestibular implants. Different pulse waveform shapes did not affect the achieved selectivity considerably but shorter pulse durations showed consistently a more selective activation of the target nerves. A cathodic, centered triangular waveform shape was identified as the most energy-efficient of the tested shapes. Based on these simulations we are able to recommend the monopolar, extra-labyrinthine stimulation approach with cathodic, centered triangular pulses as good trade-off between selectivity and energy consumption. Future implant designs could benefit from the findings presented here.

[1]  J.H.M. Frijns,et al.  A quantitative approach to modeling mammalian myelinated nerve fibers for electrical prosthesis design , 1994, IEEE Transactions on Biomedical Engineering.

[2]  Silvestro Micera,et al.  Artificial Balance: Restoration of the Vestibulo-Ocular Reflex in Humans with a Prototype Vestibular Neuroprosthesis , 2014, Front. Neurol..

[3]  Frank Risi,et al.  Implantation of the Semicircular Canals With Preservation of Hearing and Rotational Sensitivity: A Vestibular Neurostimulator Suitable for Clinical Research , 2012, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[4]  B. J. Moxham,et al.  The legal and ethical framework governing Body Donation in EuropeA review of current practice and recommendations for good practice , 2008 .

[5]  Nils Guinand,et al.  The Modified Ampullar Approach for Vestibular Implant Surgery: Feasibility and Its First Application in a Human with a Long-Term Vestibular Loss , 2012, Front. Neur..

[6]  J. Goldberg,et al.  Relation between discharge regularity and responses to externally applied galvanic currents in vestibular nerve afferents of the squirrel monkey. , 1984, Journal of neurophysiology.

[7]  Ketul M Parikh Modeling the electrical stimulation of peripheral vestibular nerves , 2006 .

[8]  R. Triolo,et al.  Selective stimulation of the human femoral nerve with a flat interface nerve electrode , 2010, Journal of neural engineering.

[9]  C. D. Della Santina,et al.  Progress Toward Development of a Multichannel Vestibular Prosthesis for Treatment of Bilateral Vestibular Deficiency , 2012, Anatomical record.

[10]  Ramindar S. Dhillon,et al.  The vestibular nerve , 1989 .

[11]  B M Clopton,et al.  Tissue impedance and current flow in the implanted ear. Implications for the cochlear prosthesis. , 1982, The Annals of otology, rhinology & laryngology. Supplement.

[12]  C. E. Smith,et al.  A stochastic afterhyperpolarization model of repetitive activity in vestibular afferents , 1986, Biological Cybernetics.

[13]  Warren M. Grill,et al.  Stimulus waveforms for selective neural stimulation , 1995 .

[14]  Warren M Grill,et al.  Efficiency Analysis of Waveform Shape for Electrical Excitation of Nerve Fibers , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[16]  C. Hildebrand,et al.  Relation between myelin sheath thickness and axon size in spinal cord white matter of some vertebrate species , 1978, Journal of the Neurological Sciences.

[17]  Werner Platzer,et al.  Ein neues Konservierungs- und Aufbewahrungssystem für anatomisches Material , 1978 .

[18]  Silvestro Micera,et al.  A Computational Framework for Electrical Stimulation of Vestibular Nerve , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[19]  Charles C. Della Santina,et al.  A Multichannel Semicircular Canal Neural Prosthesis Using Electrical Stimulation to Restore 3-D Vestibular Sensation , 2007, IEEE Transactions on Biomedical Engineering.

[20]  Patrik Raudaschl,et al.  Analysis of Vestibular Labyrinthine Geometry and Variation in the Human Temporal Bone , 2018, Front. Neurosci..

[21]  J. Goldberg,et al.  The vestibular nerve of the chinchilla. II. Relation between afferent response properties and peripheral innervation patterns in the semicircular canals. , 1988, Journal of neurophysiology.

[22]  C. D. Della Santina,et al.  Effects of Biphasic Current Pulse Frequency, Amplitude, Duration, and Interphase Gap on Eye Movement Responses to Prosthetic Electrical Stimulation of the Vestibular Nerve , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[23]  Cameron C McIntyre,et al.  Evaluation of novel stimulus waveforms for deep brain stimulation , 2010, Journal of neural engineering.

[24]  J T Mortimer,et al.  Experimental nondestructive electrical stimulation of the brain and spinal cord. , 1970, Journal of neurosurgery.

[25]  José L Bueno-López,et al.  The legal and ethical framework governing Body Donation in Europe - 1st update on current practice , 2012 .

[26]  J. Schwarz,et al.  Na currents and action potentials in rat myelinated nerve fibres at 20 and 37° C , 1987, Pflügers Archiv.

[27]  H. Kingma,et al.  Vestibular assistance systems: promises and challenges , 2016, Journal of Neurology.

[28]  L. S. Robblee,et al.  The Electrochemistry Of Electrical Stimulation , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[29]  Warren M Grill,et al.  Energy-efficient waveform shapes for neural stimulation revealed with a genetic algorithm , 2010, Journal of neural engineering.

[30]  M. Sahin,et al.  Non-rectangular waveforms for neural stimulation with practical electrodes , 2007, Journal of neural engineering.

[31]  J. Hursh CONDUCTION VELOCITY AND DIAMETER OF NERVE FIBERS , 1939 .

[32]  H. Kingma,et al.  Vestibular Implants: 8 Years of Experience with Electrical Stimulation of the Vestibular Nerve in 11 Patients with Bilateral Vestibular Loss , 2015, ORL.

[33]  J. Goldberg,et al.  The vestibular nerve of the chinchilla. I. Peripheral innervation patterns in the horizontal and superior semicircular canals. , 1988, Journal of neurophysiology.

[34]  Americo A. Migliaccio,et al.  Virtual labyrinth model of vestibular afferent excitation via implanted electrodes: validation and application to design of a multichannel vestibular prosthesis , 2011, Experimental Brain Research.

[35]  Jean-Philippe Guyot,et al.  Eye Movements in Response to Electrical Stimulation of the Lateral and Superior Ampullary Nerves , 2011, The Annals of otology, rhinology, and laryngology.

[36]  A. Ishiyama,et al.  Estimation of the number of nerve fibers in the human vestibular endorgans using unbiased stereology and immunohistochemistry , 2005, Journal of Neuroscience Methods.

[37]  Patrik Raudaschl,et al.  Model-based Vestibular Afferent Stimulation: Modular Workflow for Analyzing Stimulation Scenarios in Patient Specific and Statistical Vestibular Anatomy , 2017, Front. Neurosci..

[38]  J. Goldberg,et al.  The vestibular nerve of the chinchilla. V. Relation between afferent discharge properties and peripheral innervation patterns in the utricular macula. , 1990, Journal of neurophysiology.

[39]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[40]  Hang Si,et al.  TetGen, a Delaunay-Based Quality Tetrahedral Mesh Generator , 2015, ACM Trans. Math. Softw..

[41]  F. Dodge,et al.  Sodium currents in the myelinated nerve fibre of Xenopus laevis investigated with the voltage clamp technique , 1959, The Journal of physiology.

[42]  Silvestro Micera,et al.  A Computational Model for the Stimulation of Rat Sciatic Nerve Using a Transverse Intrafascicular Multichannel Electrode , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.