Metrological parameters of sulphur dioxide amperometric sensor containing addition of aprotic solvents

Abstract The paper presents the results of investigation on influence of aprotic solvents contained in an internal electrolyte on metrological parameters of a prototype of sulphur dioxide sensor with Nafion membrane. Five sensors differing in composition of the internal electrolyte have been compared. Gold electrode vacuum sublimation deposited on the Nafion membrane surface was a working electrode. The electrolytes were aqueous solutions of sulphuric acid of the summary concentration 5 mol dm−3 (electrolyte A). The electrolyte B contained an addition of dimethylsulphoxide (DMSO), the electrolyte C contained an addition of N,N-dimethylformamide (DMF), the electrolyte D contained an addition of acetonitrile (AC) and the electrolyte E contained an addition of propylene carbonate (PC); water/solvent molar ratio in these solutions was 2:1. Based on a proposed equation an influence of the analyte flow rate on the sensor signal and response time to changes of SO2 concentration was investigated.

[1]  Bogdan Chachulski Amperometric sulfur dioxide gas sensor with dimethyl sulfoxide as solvent for internal electrolyte solution , 1998 .

[2]  D. T. Sawyer,et al.  Electrochemistry of carbon dioxide in dimethyl sulfoxide at gold and mercury electrodes , 1967 .

[3]  A. Sammells,et al.  Ambient Temperature Gas Phase CO 2 Reduction to Hydrocarbons at Solid Polymer Electrolyte Cells , 1988 .

[4]  R W Garber,et al.  Determination of atmospheric sulfur dioxide by differential pulse polarography. , 1972, Analytical chemistry.

[5]  Gino Bontempelli,et al.  Amperometric monitoring of ozone in gaseous media by gold electrodes supported on ion exchange membranes (solid polymer electrolytes) , 1990 .

[6]  F. Opekar,et al.  Indicator and reference platinum | solid polymer electrolyte electrodes for a simple solid-state amperometric hydrogen sensor , 1994 .

[7]  Beat Müller,et al.  Determination of methane and other small hydrocarbons with a platinum–Nafion electrode by stripping voltammetry , 2001 .

[8]  P. T. Moseley,et al.  Techniques and Mechanisms in Gas Sensing , 1991 .

[9]  P. Delahay,et al.  Advances in Electrochemistry and Electrochemical Engineering , 1964 .

[10]  C. Hahn,et al.  The development of new microelectrode gas sensors: an odyssey. Part 1. O2 and CO2 reduction at unshielded gold microdisc electrodes , 1995 .

[11]  Peter C. Hauser,et al.  Amperometric detection of NO and NO2 in the ppb range with solid-polymer electrolyte membrane supported noble metal electrodes , 2001 .

[12]  Irving Fatt,et al.  Polarographic Oxygen Sensors , 1976 .

[13]  Rosanna Toniolo,et al.  Electrochemical Detection of Trace Hydrogen Sulfide in Gaseous Samples by Porous Silver Electrodes Supported on Ion-Exchange Membranes (Solid Polymer Electrolytes) , 1995 .

[14]  N. Comisso,et al.  Pulsed amperometric detection of ethanol in breath by gold electrodes supported on ion exchange membranes (solid polymer electrolytes) , 1996 .

[15]  C. Hahn,et al.  The development of new microelectrode gas sensors: an odyssey. Part III. O2 and N2O reduction at unshielded and membrane-covered gold microdisc electrodes , 1997 .

[16]  P. Hauptmann Sensors: A Comprehensive Survey , 1996 .

[17]  Jacek Gębicki,et al.  Impedance Investigations of Amperometric Gas Sensor Containing Aprotic Solvent , 2006 .

[18]  Rosanna Toniolo,et al.  Amperometric monitoring of sulphur dioxide in liquid and air samples of low conductivity by electrodes supported on ion-exchange membranes , 1991 .

[19]  Bogdan Chachulski,et al.  Influence of aprotic solvent on a signal of an amperometric sensor with Nafion® membrane , 2006 .

[20]  C. Heitner-Wirguin Recent advances in perfluorinated ionomer membranes : structure, properties and applications , 1996 .

[21]  Joseph R. Stetter,et al.  Microfabricated amperometric gas sensors , 1988 .

[22]  F. Opekar An amperometric solid‐state sensor for Nitrogen dioxide based on a solid polymer electrolyte , 1992 .

[23]  C. E. W. Hahn,et al.  Tutorial Review. Electrochemical analysis of clinicalblood-gases, gases and vapours , 1998 .

[24]  Erich Gnaiger,et al.  Polarographic Oxygen Sensors , 1983, Springer Berlin Heidelberg.