A digital x-ray tomosynthesis coupled near infrared spectral tomography system for dual-modality breast imaging.

A Near Infrared Spectral Tomography (NIRST) system has been developed and integrated into a commercial Digital Breast Tomosynthesis (DBT) scanner to allow structural and functional imaging of breast in vivo. The NIRST instrument uses an 8-wavelength continuous wave (CW) laser-based scanning source assembly and a 75-element silicon photodiode solid-state detector panel to produce dense spectral and spatial projection data from which spectrally constrained 3D tomographic images of tissue chromophores are produced. Integration of the optical imaging system into the DBT scanner allows direct co-registration of the optical and DBT images, while also facilitating the synergistic use of x-ray contrast as anatomical priors in optical image reconstruction. Currently, the total scan time for a combined NIRST-DBT exam is ~50s with data collection from 8 wavelengths in the optical scan requiring ~42s to complete. The system was tested in breast simulating phantoms constructed using intralipid and blood in an agarose matrix with a 3 cm x 2 cm cylindrical inclusion at 1 cm depth from the surface. Diffuse image reconstruction of total hemoglobin (HbT) concentration resulted in accurate recovery of the lateral size and position of the inclusion to within 6% and 8%, respectively. Use of DBT structural priors in the NIRST reconstruction process improved the quantitative accuracy of the HbT recovery, and led to linear changes in imaged versus actual contrast, underscoring the advantages of dual-modality optical imaging approaches. The quantitative accuracy of the system can be further improved with independent measurements of scattering properties through integration of frequency or time domain data.

[1]  Constantine Gatsonis,et al.  Comparison of acquisition parameters and breast dose in digital mammography and screen-film mammography in the American College of Radiology Imaging Network digital mammographic imaging screening trial. , 2010, AJR. American journal of roentgenology.

[2]  Andrew D. A. Maidment,et al.  The future of medical imaging. , 2010, Radiation protection dosimetry.

[3]  K D Paulsen,et al.  Calibration of near-infrared frequency-domain tissue spectroscopy for absolute absorption coefficient quantitation in neonatal head-simulating phantoms. , 2000, Journal of biomedical optics.

[4]  B. Pogue,et al.  A parallel-detection frequency-domain near-infrared tomography system for hemoglobin imaging of the , 2001 .

[5]  Brian W Pogue,et al.  Strategies for absolute calibration of near infrared tomographic tissue imaging. , 2003, Advances in experimental medicine and biology.

[6]  Harry L Graber,et al.  Optomechanical imaging system for breast cancer detection. , 2011, Journal of the Optical Society of America. A, Optics, image science, and vision.

[7]  Ioannis Sechopoulos,et al.  Clinical digital breast tomosynthesis system: dosimetric characterization. , 2012, Radiology.

[8]  Zhenxue Jing,et al.  Measurement of breast density with digital breast tomosynthesis , 2012, Medical Imaging.

[9]  Randall L Barbour,et al.  Digital optical tomography system for dynamic breast imaging. , 2011, Journal of biomedical optics.

[10]  Ehsan Samei,et al.  The quantitative potential for breast tomosynthesis imaging. , 2010, Medical physics.

[11]  N. Chen,et al.  Simultaneous near-infrared diffusive light and ultrasound imaging. , 2001, Applied optics.

[12]  B. Pogue,et al.  Combining near-infrared tomography and magnetic resonance imaging to study in vivo breast tissue: implementation of a Laplacian-type regularization to incorporate magnetic resonance structure. , 2005, Journal of biomedical optics.

[13]  E. Miller,et al.  Combined optical and X-ray tomosynthesis breast imaging. , 2011, Radiology.

[14]  Eric L. Miller,et al.  Combined optical imaging and mammography of the healthy breast: Optical contrast derived from breast structure and compression , 2009, IEEE Transactions on Medical Imaging.

[15]  E. Miller,et al.  Tomographic optical breast imaging guided by three-dimensional mammography. , 2003, Applied optics.

[16]  J. Baker,et al.  Breast tomosynthesis: state-of-the-art and review of the literature. , 2011, Academic radiology.

[17]  M. Schweiger,et al.  Uniqueness and wavelength optimization in continuous-wave multispectral diffuse optical tomography. , 2003, Optics letters.

[18]  B. Pogue,et al.  Near-infrared (NIR) tomography breast image reconstruction with a priori structural information from MRI: algorithm development for reconstructing heterogeneities , 2003 .

[19]  A. Kienle,et al.  Optical properties of fat emulsions. , 2008, Optics express.

[20]  B. Pogue,et al.  Near-Infrared Characterization of Breast Tumors In Vivo using Spectrally-Constrained Reconstruction , 2005, Technology in cancer research & treatment.

[21]  M. Schweiger,et al.  Diffuse optical tomography with spectral constraints and wavelength optimization. , 2005, Applied optics.

[22]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[23]  Hamid Dehghani,et al.  Near infrared optical tomography using NIRFAST: Algorithm for numerical model and image reconstruction. , 2009, Communications in numerical methods in engineering.