Microwave ablation versus radiofrequency ablation in the kidney: high-power triaxial antennas create larger ablation zones than similarly sized internally cooled electrodes.

PURPOSE To determine whether microwave ablation with high-power triaxial antennas creates significantly larger ablation zones than radiofrequency (RF) ablation with similarly sized internally cooled electrodes. MATERIALS AND METHODS Twenty-eight 12-minute ablations were performed in an in vivo porcine kidney model. RF ablations were performed with a 200-W pulsed generator and either a single 17-gauge cooled electrode (n = 9) or three switched electrodes spaced 1.5 cm apart (n = 7). Microwave ablations were performed with one (n = 7), two (n = 3), or three (n = 2) 17-gauge triaxial antennas to deliver 90 W continuous power per antenna. Multiple antennas were powered simultaneously. Temperatures 1 cm from the applicator were measured during two RF and microwave ablations each. Animals were euthanized after ablation and ablation zone diameter, cross-sectional area, and circularity were measured. Comparisons between groups were performed with use of a mixed-effects model with P values less than .05 indicating statistical significance. RESULTS No adverse events occurred during the procedures. Three-electrode RF (mean area, 14.7 cm(2)) and single-antenna microwave (mean area, 10.9 cm(2)) ablation zones were significantly larger than single-electrode RF zones (mean area, 5.6 cm(2); P = .001 and P = .0355, respectively). No significant differences were detected between single-antenna microwave and multiple-electrode RF. Ablation zone circularity was similar across groups (P > .05). Tissue temperatures were higher during microwave ablation (maximum temperature of 123 degrees C vs 100 degrees C for RF). CONCLUSIONS Microwave ablation with high-power triaxial antennas created larger ablation zones in normal porcine kidneys than RF ablation with similarly sized applicators.

[1]  Division on Earth Guide for the Care and Use of Laboratory Animals , 1996 .

[2]  J. Mclaughlin,et al.  The epidemiology of renal cell carcinoma. , 2006, The Journal of urology.

[3]  David C. Alsop,et al.  Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma1 , 2005 .

[4]  R. Leggett,et al.  Reference values for resting blood flow to organs of man. , 1989, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[5]  I. Thompson,et al.  Serendipitous renal cell carcinoma in the post-CT era: continued evidence in improved outcomes. , 2003, Urologic oncology.

[6]  W. Linehan,et al.  Radio frequency ablation of small renal tumors:: intermediate results. , 2004, The Journal of urology.

[7]  G S Gazelle,et al.  Percutaneous radiofrequency tissue ablation: optimization of pulsed-radiofrequency technique to increase coagulation necrosis. , 1999, Journal of vascular and interventional radiology : JVIR.

[8]  D. Gervais,et al.  Radiofrequency ablation of renal cell carcinoma: part 2, Lessons learned with ablation of 100 tumors. , 2005, AJR. American journal of roentgenology.

[9]  F. Lee,et al.  Radiofrequency versus microwave ablation in a hepatic porcine model. , 2005, Radiology.

[10]  P. Clark,et al.  Microwave ablation of renal parenchymal tumors before nephrectomy: phase I study. , 2007, AJR. American journal of roentgenology.

[11]  Ping Liang,et al.  Ultrasound guided percutaneous microwave ablation for small renal cancer: initial experience. , 2008, The Journal of urology.

[12]  S Nahum Goldberg,et al.  Image-guided tumor ablation: standardization of terminology and reporting criteria. , 2005, Journal of vascular and interventional radiology : JVIR.

[13]  Christopher L Brace,et al.  Microwave ablation with a single small-gauge triaxial antenna: in vivo porcine liver model. , 2007, Radiology.

[14]  Christopher L Brace,et al.  Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model. , 2007, Radiology.

[15]  Christopher L Brace,et al.  Microwave ablation with triaxial antennas tuned for lung: results in an in vivo porcine model. , 2008, Radiology.

[16]  D. Iannitti,et al.  Guidelines for power and time variables for microwave ablation in an in vivo porcine kidney. , 2009, The Journal of surgical research.

[17]  D. Gervais,et al.  Radiofrequency ablation of renal cell carcinoma: part 1, Indications, results, and role in patient management over a 6-year period and ablation of 100 tumors. , 2005, AJR. American journal of roentgenology.

[18]  T. Winter,et al.  Multiple-electrode radiofrequency ablation: comparison with a conventional cluster electrode in an in vivo porcine kidney model. , 2007, Journal of vascular and interventional radiology : JVIR.

[19]  J L Warren,et al.  Rising incidence of renal cell cancer in the United States. , 1999, JAMA.

[20]  D. W. van der Weide,et al.  Microwave ablation with a triaxial antenna: results in ex vivo bovine liver , 2005, IEEE Transactions on Microwave Theory and Techniques.

[21]  Dieter Haemmerich,et al.  Contribution of Direct Heating, Thermal Conduction and Perfusion During Radiofrequency and Microwave Ablation , 2007, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  Young Jun Kim,et al.  Microwave liver ablation: influence of hepatic vein size on heat-sink effect in a porcine model. , 2008, Journal of vascular and interventional radiology : JVIR.

[23]  S. Hayasaka,et al.  Oncologic efficacy of CT-guided percutaneous radiofrequency ablation of renal cell carcinomas. , 2007, AJR. American journal of roentgenology.