Effect of Loop Diameter on the Steady State and Stability Behaviour of Single-Phase and Two-Phase Natural Circulation Loops

In natural circulation loops, the driving force is usually low as it depends on the riser height which is generally of the order of a few meters. The heat transport capability of natural circulation loops (NCLs) is directly proportional to the flow rate it can generate. With low driving force, the straightforward way to enhance the flow is to reduce the frictional losses. A simple way to do this is to increase the loop diameter which can be easily adopted in pressure tube designs such as the AHWR and the natural circulation boilers employed in fossil-fuelled power plants. Further, the loop diameter also plays an important role on the stability behavior. An extensive experimental and theoretical investigation of the effect of loop diameter on the steady state and stability behavior of single- and two-phase natural circulation loops have been carried out and the results of this study are presented in this paper.

[1]  Hiroyasu Mochizuki Experimental and Analytical Studies of Flow Instabilities in Pressure Tube Type Heavy Water Reactors , 1992 .

[2]  Kenneth E. Torrance,et al.  Transient and steady behavior of an open, symmetrically-heated, free convection loop , 1981 .

[3]  P. Vijayan,et al.  Study on the stability behaviour of two-phase natural circulation systems using a four-equation drift flux model , 2007 .

[4]  M. Ishii,et al.  Flow regime transition criteria for upward two-phase flow in vertical tubes , 1984 .

[5]  O. B. Samoilov,et al.  Nuclear district heating plants AST-500. Present status and prospects for future in Russia , 1997 .

[6]  G. Yadigaroglu,et al.  Two-phase flow instabilities and propagation phenomena , 1978 .

[7]  V. A. Silin,et al.  The Light Water Integral Reactor with natural circulation of the coolant at supercritical pressure B-500 SKDI , 1993 .

[8]  J. P. Holman,et al.  Heat Transfer to Freon 12 Near the Critical State in a Natural-Circulation Loop , 1960 .

[9]  R. Greif Natural Circulation Loops , 1988 .

[10]  P. Garibaldi,et al.  Experiments in a single-phase natural circulation mini-loop , 2007 .

[11]  E. Royer,et al.  The 1995 look-up table for critical heat flux in tubes , 1996 .

[12]  R. K. Sinha,et al.  Analytical study of flow instability behaviour in a boiling two-phase natural circulation loop under low quality conditions , 2002, Kerntechnik.

[13]  A. E. Dukler,et al.  Modelling flow pattern transitions for steady upward gas‐liquid flow in vertical tubes , 1980 .

[14]  M. Ishii,et al.  One-dimensional drift-flux model and constitutive equations for relative motion between phases in various two-phase flow regimes , 2003 .

[15]  Giovanni Tanda,et al.  EXPERIMENTS IN A FREE CONVECTION RECTANGULAR LOOP , 1992 .

[16]  Yoram Zvirin,et al.  A review of natural circulation loops in pressurized water reactors and other systems , 1981 .

[17]  Kenji Fukuda,et al.  Classification of two-phase flow instability by density wave oscillation model. , 1979 .

[18]  Bin-Juine Huang,et al.  Heat transfer behavior of a rectangular thermosyphon loop , 1988 .

[19]  P. Vijayan,et al.  Steady state and stability characteristics of single-phase natural circulation in a rectangular loop with different heater and cooler orientations , 2007 .

[20]  Pallippattu Krishnan Vijayan,et al.  A generalized flow correlation for two-phase natural circulation loops , 2006 .

[21]  A. E. Bergles,et al.  Review of two-phase flow instability , 1973 .

[22]  Francesco Saverio D'Auria,et al.  Transient and stability analysis in single-phase natural circulation , 2004 .

[23]  T. N. Veziroglu,et al.  A Review of Two-Phase Flow Instabilities , 1983 .

[24]  Ching-Jenq Ho,et al.  Heat transfer characteristics of a rectangular natural circulation loop containing water near its density extreme , 1997 .