Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material.

Time-resolved measurements of the temperature field in an agar-based tissue-mimicking phantom insonated with a large aperture 1-MHz focused acoustic transducer are reported. The acoustic pressure amplitude and insonation duration were varied. Above a critical threshold acoustic pressure, a large increase in the temperature rise during insonation was observed. Evidence for the hypothesis that cavitation bubble activity in the focal zone is the cause of enhanced heating is presented and discussed. Mechanisms for bubble-assisted heating are presented and modeled, and quantitative estimates for the thermal power generated by viscous dissipation and bubble acoustic radiation are given.

[1]  Padmakar P. Lele,et al.  Effects of Ultrasound on “Solid” Mammalian Tissues and Tumors In Vivo , 1987 .

[2]  J. Tavakkoli,et al.  Ultrasound-induced tissue ablation: studies on isolated, perfused porcine liver. , 1998, Ultrasound in medicine & biology.

[3]  J. Tavakkoli,et al.  A piezocomposite shock wave generator with electronic focusing capability: application for producing cavitation-induced lesions in rabbit liver. , 1997, Ultrasound in medicine & biology.

[4]  R. G. Holt,et al.  Experimental observations of bubble response and light intensity near the threshold for single bubble sonoluminescence in an air-water system. , 1999, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[5]  I.H. Rivens,et al.  Design of focused ultrasound surgery transducers , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  P. Lenz,et al.  Reduction of cavitation using pseudorandom signals [therapeutic US] , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  J. Chapelon,et al.  Modeling of high-intensity focused ultrasound-induced lesions in the presence of cavitation bubbles , 2000, The Journal of the Acoustical Society of America.

[8]  D. R. Bacon,et al.  Increased heating by diagnostic ultrasound due to nonlinear propagation. , 1990, The Journal of the Acoustical Society of America.

[9]  Kevin J. Parker,et al.  The thermal pulse decay technique for measuring ultrasonic absorption coefficients , 1983 .

[10]  K. Hynynen The threshold for thermally significant cavitation in dog's thigh muscle in vivo. , 1991, Ultrasound in medicine & biology.

[11]  T. Leighton The Acoustic Bubble , 1994 .

[12]  J. Saunders,et al.  Detection of acoustic emission from cavitation in tissue during clinical extracorporeal lithotripsy. , 1996, Ultrasound in medicine & biology.

[13]  Andrea Prosperetti,et al.  Bubble oscillations in the nearly adiabatic limit , 1992 .

[14]  M. Bailey Control of acoustic cavitation with application to lithotripsy , 1997 .

[15]  W. Fry,et al.  Physical Factors Involved in Ultrasonically Induced Changes in Living Systems: I. Identification of Non‐Temperature Effects , 1950 .

[16]  J. Lehmann,et al.  Biologic reactions to cavitation, a consideration for ultrasonic therapy. , 1953, Archives of physical medicine and rehabilitation.

[17]  Andrea Prosperetti,et al.  Thermal effects and damping mechanisms in the forced radial oscillations of gas bubbles in liquids , 1977 .

[18]  D. R. Bacon,et al.  Absorption of finite amplitude focused ultrasound. , 1991, The Journal of the Acoustical Society of America.

[19]  Kondic,et al.  Theoretical studies of sonoluminescence radiation: Radiative transfer and parametric dependence. , 1995, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[20]  Bradley P. Barber,et al.  Observation of synchronous picosecond sonoluminescence , 1991, Nature.

[21]  J Y Chapelon,et al.  New piezoelectric transducers for therapeutic ultrasound. , 2000, Ultrasound in medicine & biology.

[22]  E. Carstensen,et al.  Morphological effects of pulsed ultrasound in the lung. , 1993, Ultrasound in medicine & biology.

[23]  Michael J. Miksis,et al.  Bubble Oscillations of Large Amplitude , 1980 .

[24]  F. Fry,et al.  Ultrasound and microbubbles: their generation, detection and potential utilization in tissue and organ therapy--experimental. , 1995, Ultrasound in medicine & biology.

[25]  C R Hill,et al.  Ultrasonically induced cavitation in vivo. , 1982, The British journal of cancer. Supplement.

[26]  Ronald A. Roy,et al.  On the role of shear viscosity in mediating inertial cavitation from short-pulse, megahertz-frequency ultrasound , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  J. Wu,et al.  Temperature rise generated by ultrasound in the presence of contrast agent. , 1998, Ultrasound in medicine & biology.

[28]  R. Apfel,et al.  Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound. , 1991, Ultrasound in medicine & biology.

[29]  G. ter Haar,et al.  Temperature rise recorded during lesion formation by high-intensity focused ultrasound. , 1997, Ultrasound in medicine & biology.

[30]  Joseph B. Keller,et al.  Damping of Underwater Explosion Bubble Oscillations , 1956 .

[31]  R. C. Eggleton,et al.  Threshold ultrasonic dosages for structural changes in the mammalian brain. , 1970, The Journal of the Acoustical Society of America.

[32]  C. Church,et al.  Prediction of rectified diffusion during nonlinear bubble pulsations at biomedical frequencies. , 1988, The Journal of the Acoustical Society of America.

[33]  Ronald A. Roy,et al.  Optimal acoustic parameters for induced hyperthermia from focused MHz ultrasound: Phantom measurements with fluid flow and bubble activity , 1998 .

[34]  Y. Nishimura,et al.  Increased heating efficiency of hyperthermia using an ultrasound contrast agent: a phantom study. , 1998, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[35]  C. Damianou,et al.  Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose. , 1997, The Journal of the Acoustical Society of America.

[36]  S Daniels,et al.  Damage to red blood cells induced by acoustic cavitation. , 1995, Ultrasound in medicine & biology.

[37]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[38]  J C Bamber,et al.  Acoustic properties of lesions generated with an ultrasound therapy system. , 1993, Ultrasound in medicine & biology.

[39]  T. Ponchon,et al.  Characterization of extracorporeal ablation of normal and tumor-bearing liver tissue by high intensity focused ultrasound. , 1993, Ultrasound in medicine & biology.

[40]  A. Prosperetti,et al.  The Effect of Viscosity on the Spherical Stability of Oscillating Gas Bubbles , 1999 .

[41]  D. Miller,et al.  The interaction of ultrasonic heating and cavitation in vascular bioeffects on mouse intestine. , 1998, Ultrasound in medicine & biology.

[42]  R. Schlief,et al.  The Effects of the Microbubble Suspension SH U 454 (Echovist®) on Ultrasound‐Induced Cell Lysis In a Rotating Tube Exposure System , 1991, Echocardiography.

[43]  F. Dunn,et al.  Compilation of empirical ultrasonic properties of mammalian tissues. II. , 1980, The Journal of the Acoustical Society of America.

[44]  J B Fowlkes,et al.  Mechanical bioeffects from diagnostic ultrasound: AIUM consensus statements. American Institute of Ultrasound in Medicine. , 2000, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[45]  C. Church,et al.  A theoretical study of cavitation generated by an extracorporeal shock wave lithotripter. , 1988, The Journal of the Acoustical Society of America.

[46]  Lohse,et al.  Bubble shape oscillations and the onset of sonoluminescence. , 1995, Physical review letters.

[47]  R S Meltzer,et al.  Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro. , 1997, Ultrasound in medicine & biology.

[48]  K Hynynen,et al.  The feasibility of using focused ultrasound for transmyocardial revascularization. , 1998, Ultrasound in medicine & biology.

[49]  L A Crum,et al.  Growth of air bubbles in tissue by rectified diffusion. , 1982, Physics in medicine and biology.

[50]  G. Haar,et al.  Ultrasound focal beam surgery. , 1995 .

[51]  E. Carstensen,et al.  Lysis of erythrocytes by exposure to CW ultrasound. , 1993, Ultrasound in medicine & biology.

[52]  F A Jolesz,et al.  Demonstration of potential noninvasive ultrasound brain therapy through an intact skull. , 1998, Ultrasound in medicine & biology.

[53]  J. Chapelon,et al.  Effects of cavitation in the high intensity therapeutic ultrasound , 1991, IEEE 1991 Ultrasonics Symposium,.

[54]  W. Nyborg Solutions of the bio-heat transfer equation. , 1988, Physics in medicine and biology.

[55]  E. Carstensen,et al.  Finite amplitude distortion and its relationship to linear derating formulae for diagnostic ultrasound systems. , 1996, Ultrasound in medicine & biology.

[56]  Lawrence A. Crum,et al.  Instability of the Motion of a Pulsating Bubble in a Sound Field , 1970 .

[57]  Andrea Prosperetti,et al.  The thermal behaviour of oscillating gas bubbles , 1991, Journal of Fluid Mechanics.

[58]  Richard Bihrle,et al.  Noninvasive surgery of prostate tissue by high-intensity focused ultrasound , 1996 .

[59]  Anthony I. Eller,et al.  Rectified Diffusion during Nonlinear Pulsations of Cavitation Bubbles , 1963 .

[60]  D. Lohse,et al.  Sound scattering and localized heat deposition of pulse-driven microbubbles , 2000, The Journal of the Acoustical Society of America.