Impact of physiological variables and genetic background on myocardial frequency-resistivity relations in the intact beating murine heart.

Conductance measurements for generation of an instantaneous left ventricular (LV) volume signal in the mouse are limited, because the volume signal is a combination of blood and LV muscle, and only the blood signal is desired. We have developed a conductance system that operates at two simultaneous frequencies to identify and remove the myocardial contribution to the instantaneous volume signal. This system is based on the observation that myocardial resistivity varies with frequency, whereas blood resistivity does not. For calculation of LV blood volume with the dual-frequency conductance system in mice, in vivo murine myocardial resistivity was measured and combined with an analytic approach. The goals of the present study were to identify and minimize the sources of error in the measurement of myocardial resistivity to enhance the accuracy of the dual-frequency conductance system. We extended these findings to a gene-altered mouse model to determine the impact of measured myocardial resistivity on the calculation of LV pressure-volume relations. We examined the impact of temperature, timing of the measurement during the cardiac cycle, breeding strain, anisotropy, and intrameasurement and interanimal variability on the measurement of intact murine myocardial resistivity. Applying this knowledge to diabetic and nondiabetic 11- and 20- to 24-wk-old mice, we demonstrated differences in myocardial resistivity at low frequencies, enhancement of LV systolic function at 11 wk and LV dilation at 20-24 wk, and histological and electron-microscopic studies demonstrating greater glycogen deposition in the diabetic mice. This study demonstrated the accurate technique of measuring myocardial resistivity and its impact on the determination of LV pressure-volume relations in gene-altered mice.

[1]  H. Taegtmeyer,et al.  Adaptation and Maladaptation of the Heart in Diabetes: Part II: Potential Mechanisms , 2002, Circulation.

[2]  Chia-Ling Wei,et al.  Design of instrumentation and data-acquisition system for complex admittance measurement. , 2004, Biomedical sciences instrumentation.

[3]  Ronald R. Watson,et al.  Validation of Conductance Catheter System for Quantification of Murine Pressure-Volume Loops , 2001, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[4]  K. Larsson,et al.  Increased Incidence of Congenital Malformations in the Offspring of Diabetic Rats and Their Prevention by Maternal Insulin Therapy , 1982, Diabetes.

[5]  N. Sperelakis,et al.  Impedance analysis applicable to cardiac muscle and smooth muscle bundles , 1991, IEEE Transactions on Biomedical Engineering.

[6]  G L Freeman,et al.  Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals. , 2000, American journal of physiology. Heart and circulatory physiology.

[7]  G. Lubec,et al.  L‐Arginine Reduces Heart Collagen Accumulation in the Diabetic db/db Mouse , 1994, Circulation.

[8]  J A Pearce,et al.  Development of a multifrequency conductance catheter-based system to determine LV function in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[9]  D. Severson,et al.  Age-dependent changes in metabolism, contractile function, and ischemic sensitivity in hearts from db/db mice. , 2003, Diabetes.

[10]  佐川 喜一,et al.  Cardiac contraction and the pressure-volume relationship , 1988 .

[11]  A A Shoukas,et al.  Does volume catheter parallel conductance vary during a cardiac cycle? , 1990, The American journal of physiology.

[12]  N. Sperelakis,et al.  Electrical Impedance of Cardiac Muscle , 1961, Circulation research.

[13]  A. Redington,et al.  The effect of changing excitation frequency on parallel conductance in different sized hearts. , 1998, Cardiovascular research.

[14]  O'Bryan Gt,et al.  The renal hemodynamic basis of diabetic nephropathy. , 1997 .

[15]  D. Coleman Diabetes-Obesity Syndromes in Mice , 1982, Diabetes.

[16]  Jonathan W. Valvano,et al.  Nonlinear conductance-volume relationship for murine conductance catheter measurement system , 2005, IEEE Transactions on Biomedical Engineering.

[17]  T. Hostetter,et al.  The renal hemodynamic basis of diabetic nephropathy. , 1997, Seminars in nephrology.

[18]  D. Severson,et al.  Altered metabolism causes cardiac dysfunction in perfused hearts from diabetic (db/db) mice. , 2000, American journal of physiology. Endocrinology and metabolism.

[19]  F. Giacomelli,et al.  Primary myocardial disease in the diabetic mouse. An ultrastructural study. , 1979, Laboratory investigation; a journal of technical methods and pathology.

[20]  D. Severson,et al.  Echocardiographic assessment of cardiac function in diabetic db/db and transgenic db/db-hGLUT4 mice. , 2002, American journal of physiology. Heart and circulatory physiology.

[21]  H. Reinauer,et al.  Different types of postinsulin receptor defects contribute to insulin resistance in hearts of obese Zucker rats. , 1986, Endocrinology.

[22]  D. Kass,et al.  Estimation of parallel conductance by dual-frequency conductance catheter in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[23]  Ronald M Peshock,et al.  Magnetic resonance imaging accurately estimates LV mass in a transgenic mouse model of cardiac hypertrophy. , 1998, American journal of physiology. Heart and circulatory physiology.

[24]  S. Rush,et al.  Resistivity of Body Tissues at Low Frequencies , 1963, Circulation research.

[25]  Ronald M Peshock,et al.  Magnetic Resonance Imaging and Invasive Evaluation of Development of Heart Failure in Transgenic Mice With Myocardial Expression of Tumor Necrosis Factor-α , 1999 .

[26]  C. H. Chen,et al.  Special Communication , 2004 .

[27]  G. Freeman,et al.  Enhanced left ventricular systolic function early in type 2 diabetic mice: clinical implications , 2004, Diabetes & vascular disease research.

[28]  D. D. Streeter Engineering Mechanics for Successive States in Canine Left Ventricular Myocardium: I. CAVITY AND WALL GEOMETRY , 1973, Circulation research.

[29]  T J Gawne,et al.  Estimating left ventricular offset volume using dual-frequency conductance catheters. , 1987, Journal of applied physiology.

[30]  H. P. Schwan,et al.  Electrical properties of blood and its constitutents: Alternating current spectroscopy , 1983, Blut: Zeitschrift für die Gesamte Blutforschung.

[31]  H. Taegtmeyer,et al.  Adaptation and maladaptation of the heart in diabetes: Part I: general concepts. , 2002, Circulation.

[32]  P. Steendijk,et al.  Dependence of anisotropic myocardial electrical resistivity on cardiac phase and excitation frequency , 1994, Basic Research in Cardiology.

[33]  A. Haase,et al.  Perfusion‐corrected mapping of cardiac regional blood volume in rats in vivo , 1999, Magnetic resonance in medicine.

[34]  L. Tartaglia,et al.  Evidence That the Diabetes Gene Encodes the Leptin Receptor: Identification of a Mutation in the Leptin Receptor Gene in db/db Mice , 1996, Cell.

[35]  P. Steendijk,et al.  The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivo , 1993, IEEE Transactions on Biomedical Engineering.

[36]  H. Schwan,et al.  Specific Resistance of Body Tissues , 1956, Circulation research.

[37]  B Buis,et al.  Continuous measurement of left ventricular volume in animals and humans by conductance catheter. , 1984, Circulation.

[38]  J. Ross,et al.  Fiber Orientation in the Canine Left Ventricle during Diastole and Systole , 1969, Circulation research.

[39]  U. Ruotsalainen,et al.  Insulin resistance characterizes glucose uptake in skeletal muscle but not in the heart in NIDDM , 1998, Diabetologia.

[40]  W. Lederer,et al.  Cellular and functional defects in a mouse model of heart failure. , 2000, American journal of physiology. Heart and circulatory physiology.

[41]  D. Coleman Obesity syndromes in mice. , 1981 .