A Mock Circulatory System to Assess the Performance of Continuous-Flow Left Ventricular Assist Devices (LVADs): Does Axial Flow Unload Better Than Centrifugal LVAD?

Hemodynamic performances comparisons between different types of left ventricular assist devices (LVADs) remain difficult in a clinical context. The aim of this study was to create an experimental model to assess and compare two types of LVAD under hemodynamic conditions that simulated physical effort and pulmonary hypertension. An experimental mock circulatory system was created to simulate the systemic and pulmonary circulations and consisted of pulsatile left and right cardiac simulators (cardiowest pump), air/water tanks to model compliances, and tubes to model the venous and arterial resistances. Two types of continuous-flow ventricular assist devices were connected to this pulsated model: an axial flow pump, Heartmate II (HTM II), and a centrifugal pump, VentrAssist (VTA). The hemodynamic conditions at rest and during exercise were replicated. Mean aortic pressures were not significantly different at rest and during effort but mean flow under maximum pump speed was higher with HTM II (13 L vs. 10 L, p = 0.02). Left atrial pressure was lower at rest and during effort for the HTM II (11 mm Hg vs. 3 mm Hg, p = 0.02 and 9 mm Hg vs. 2 mm Hg, p = 0.008) than with the VTA, but with greater risk of left-ventricle suck-down for the axial flow. Power consumption for a similar flow was lower with the VTA during rest (4.7 W vs. 6.9 W, p = 0.002) and during effort (4.3 W vs. 6.6 W, p = 0.008). In case of high pulmonary vascular resistance with preserved right ventricular function, lower right ventricular pressure was obtained with HTM II (21 mm Hg vs. 28 mm Hg, p = 0.03). Observed results are in favor of a better discharge of the left and right cavities with the HTM II compared to the VTA yet with a higher risk of left cavity collapse occurrence.

[1]  F. Pagani,et al.  Hemodynamic and Exercise Performance With Pulsatile and Continuous-Flow Left Ventricular Assist Devices , 2007, Circulation.

[2]  H. Scheld,et al.  Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. , 2004, The Annals of thoracic surgery.

[3]  D. Mancini,et al.  Assessment of submaximal exercise capacity in patients with left ventricular assist devices. , 1996, Circulation.

[4]  Edward Bullister,et al.  Physiologic control algorithms for rotary blood pumps using pressure sensor input. , 2002, Artificial organs.

[5]  Andrew Galbraith,et al.  A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices. , 2005, Artificial organs.

[6]  Alex Stonehouse,et al.  VentrAssist left ventricular assist systems long-term in vitro reliability. , 2009, Artificial organs.

[7]  Paul Allaire,et al.  Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing. , 2005, Artificial organs.

[8]  D. Kaye,et al.  Changes in right ventricular function during continuous-flow left ventricular assist device support [corrected]. , 2009, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[9]  Tomoyuki Yambe,et al.  Outflow control for avoiding atrial suction in a continuous flow total artificial heart. , 2003, Artificial organs.

[10]  A B de la Rivière,et al.  Exercise performance in patients with end-stage heart failure after implantation of a left ventricular assist device and after heart transplantation: an outlook for permanent assisting? , 2001, Journal of the American College of Cardiology.

[11]  David Kaye,et al.  First clinical implant of the VentrAssist left ventricular assist system as destination therapy for end-stage heart failure. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[12]  Biswajit Kar,et al.  First clinical use of the redesigned HeartMate II left ventricular assist system in the United States: a case report. , 2004, Texas Heart Institute journal.

[13]  Aron Andrade,et al.  Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases. , 2008, Artificial organs.

[14]  R. Hetzer,et al.  Reversibility of fixed pulmonary hypertension in left ventricular assist device support recipients. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[15]  M. Lachat,et al.  Normalization of high pulmonary vascular resistance with LVAD support in heart transplantation candidates. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.