Evaluation of an intact, an ACL-deficient, and a reconstructed human knee joint finite element model

The human knee joint has a three-dimensional geometry with multiple body articulations that produce complex mechanical responses under loads that occur in everyday life and sports activities. Understanding the complex mechanical interactions of these load-bearing structures is of use when the treatment of relevant diseases is evaluated and assisting devices are designed. The anterior cruciate ligament (ACL) in the knee is one of four main ligaments that connects the femur to the tibia and is often torn during sudden twisting motions, resulting in knee instability. The objective of this work is to study the mechanical behavior of the human knee joint and evaluate the differences in its response for three different states, i.e., intact, ACL-deficient, and surgically treated (reconstructed) knee. The finite element models corresponding to these states were developed. For the reconstructed model, a novel repair device was developed and patented by the author in previous work. Static load cases were applied, as have already been presented in a previous work, in order to compare the calculated results produced by the two models the ACL-deficient and the surgically reconstructed knee joint, under the exact same loading conditions. Displacements were calculated in different directions for the load cases studied and were found to be very close to those from previous modeling work and were in good agreement with experimental data presented in literature. The developed finite element model for both the intact and the ACL-deficient human knee joint is a reliable tool to study the kinematics of the human knee, as results of this study show. In addition, the reconstructed human knee joint model had kinematic behavior similar to the intact knee joint, showing that such reconstruction devices can restore human knee stability to an adequate extent.

[1]  F. Bonnel,et al.  Biomechanics of the ligaments of the human knee and of artificial ligaments , 2005, Surgical and Radiologic Anatomy.

[2]  M J Pearcy,et al.  Mechanical properties of the human anterior cruciate ligament. , 1995, Clinical biomechanics.

[3]  Tony M. Keaveny,et al.  BONE MECHANICS , 2005 .

[4]  M. Hull,et al.  A finite element model of the human knee joint for the study of tibio-femoral contact. , 2002, Journal of biomechanical engineering.

[5]  S. Woo,et al.  A three-dimensional finite element model of the human anterior cruciate ligament: a computational analysis with experimental validation. , 2004, Journal of biomechanics.

[6]  Andrew A. Amis,et al.  Isometricity and graft placement during anterior cruciate ligament reconstruction , 1995 .

[7]  M. Bendjaballah,et al.  Biomechanics of the human knee joint in compression: reconstruction, mesh generation and finite element analysis , 1995 .

[8]  E. Collings,et al.  Materials Properties Handbook: Titanium Alloys , 1994 .

[9]  Markus Wünschel,et al.  Forces in anterior cruciate ligament during simulated weight-bearing flexion with anterior and internal rotational tibial load. , 2008, Journal of biomechanics.

[10]  G. Li,et al.  Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis. , 2001, Journal of biomechanical engineering.

[11]  A Huson,et al.  A model of the human knee, derived from kinematic principles and its relevance for endoprosthesis design. , 1989, Acta morphologica Neerlando-Scandinavica.

[12]  M. Bendjaballah,et al.  Biomechanical response of the passive human knee joint under anterior-posterior forces. , 1998, Clinical biomechanics.

[13]  Miguel Ángel Martínez,et al.  A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. , 2006, Journal of biomechanics.

[14]  A. Amis,et al.  The natural history of anterior cruciate ligament reconstruction using patellar tendon autograft , 1995 .

[15]  A Shirazi-Adl,et al.  Biomechanics of passive knee joint in drawer: load transmission in intact and ACL-deficient joints. , 2003, The Knee.

[16]  M. Viceconti,et al.  Extracting clinically relevant data from finite element simulations. , 2005, Clinical biomechanics.

[17]  A. Yousif,et al.  A Statical Model of the Human Knee Joint , 2009 .

[18]  Constantinos N Maganaris,et al.  Human patellar tendon stiffness is restored following graft harvest for anterior cruciate ligament surgery. , 2009, Journal of biomechanics.

[20]  Rodrigo Rico Bini,et al.  Fatigue effects on the coordinative pattern during cycling: kinetics and kinematics evaluation. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[21]  Ivan Godler,et al.  Biomechanical study of a computer simulated reconstruction of the anterior cruciate ligament (ACL) , 2000, Comput. Biol. Medicine.

[22]  A. Amis,et al.  Biomechanics of the menisci of the knee , 2008 .