Impact of LVAD Implantation Site on Ventricular Blood Stagnation

Treatment of end-stage heart failure includes cardiac transplantation or ventricular assist device (VAD) therapy. Although increasingly prevalent, current VAD therapy has inherent complications, including thrombosis. Studies have demonstrated that VAD implantation alters intracardiac blood flow, creating areas of stagnation that predispose to thrombus formation. Two potential surgical configurations exist for VAD implantation: through the apical or diaphragmatic surfaces of the heart. We hypothesized that diaphragmatic implantation causes more stagnation than apical implantation. We also hypothesized that intermittent aortic valve (AV) opening reduces stagnation of blood inside the left ventricle (LV) when compared with a closed AV. To test these hypotheses, a human LV geometry was recreated in silico and a VAD inflow cannula was virtually implanted in each configuration. A computational indicator-dilution study was conducted where “virtually dyed blood” was washed out of the LV by injecting blood with no dye. Simulations demonstrated a substantial reduction in stagnation with intermittent AV opening. In addition, virtual dye was cleared slightly faster in the apical configuration. Simulations from our study demonstrate the clinical importance of VAD management to allow intermittent opening of the AV to prevent subvalvular stagnation, and also suggests that apical configuration might be more hemodynamically favorable.

[1]  Shmuel Einav,et al.  Device Thrombogenicity Emulation: A Novel Method for Optimizing Mechanical Circulatory Support Device Thromboresistance , 2012, PloS one.

[2]  Mark S. Slaughter,et al.  Outcomes of Left Ventricular Assist Device Implantation as Destination Therapy in the Post-REMATCH Era: Implications for Patient Selection , 2007, Circulation.

[3]  Takuji Shionoya STUDIES IN EXPERIMENTAL EXTRACORPOREAL THROMBOSIS , 1927, The Journal of experimental medicine.

[4]  Priya Sharma,et al.  The development of aortic insufficiency in continuous-flow left ventricular assist device-supported patients. , 2013, The Annals of thoracic surgery.

[5]  A. Khaghani,et al.  Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[6]  Thomas J. R. Hughes,et al.  Patient-specific isogeometric fluid–structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device , 2009 .

[7]  Liang Zhong,et al.  Fluid-dynamics modelling of the human left ventricle with dynamic mesh for normal and myocardial infarction: Preliminary study , 2012, Comput. Biol. Medicine.

[8]  A. Aliseda,et al.  LVAD Outflow Graft Angle and Thrombosis Risk , 2017, ASAIO journal.

[9]  V. L. Rayz,et al.  Flow Residence Time and Regions of Intraluminal Thrombus Deposition in Intracranial Aneurysms , 2010, Annals of Biomedical Engineering.

[10]  Shmuel Einav,et al.  Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation- optimized HeartAssist 5 VAD. , 2014, Journal of biomechanical engineering.

[11]  Francis D. Pagani,et al.  The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients , 2010, Circulation. Heart failure.

[12]  M C Oz,et al.  Long-term use of a left ventricular assist device for end-stage heart failure. , 2001, The New England journal of medicine.

[13]  J. Morgan,et al.  Stroke While on Long-Term Left Ventricular Assist Device Support: Incidence, Outcome, and Predictors , 2014, ASAIO journal.

[14]  Gianni Pedrizzetti,et al.  Three-dimensional filling flow into a model left ventricle , 2005, Journal of Fluid Mechanics.

[15]  A. Camm,et al.  Left atrial appendage: structure, function, and role in thromboembolism , 1999, Heart.

[16]  J. Butler,et al.  Epidemiology and cost of advanced heart failure. , 2011, Progress in cardiovascular diseases.

[17]  David Pastor-Escuredo,et al.  A clinical method for mapping and quantifying blood stasis in the left ventricle. , 2016, Journal of biomechanics.

[18]  E. Falk,et al.  Pathology of coronary microembolisation and no reflow , 2003, Heart.

[19]  F. Nicoud,et al.  Image-Based Simulations Show Important Flow Fluctuations in a Normal Left Ventricle: What Could be the Implications? , 2016, Annals of Biomedical Engineering.

[20]  G. Lowe Virchow’s Triad Revisited: Abnormal Flow , 2003, Pathophysiology of Haemostasis and Thrombosis.

[21]  Shmuel Einav,et al.  Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. , 2010, Journal of biomechanics.

[22]  Christof Karmonik,et al.  Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta. , 2014, The Journal of thoracic and cardiovascular surgery.

[23]  W. Piccione Left ventricular assist device implantation: short and long-term surgical complications. , 2000, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[24]  M. Slepian,et al.  Thrombus Formation Patterns in the HeartMate II Ventricular Assist Device: Clinical Observations Can Be Predicted by Numerical Simulations , 2014, ASAIO journal.

[25]  Biswajit Kar,et al.  The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling. , 2005, Texas Heart Institute journal.

[26]  Karen May-Newman,et al.  Effect of Left Ventricular Assist Device Outflow Conduit Anastomosis Location on Flow Patterns in the Native Aorta , 2006, ASAIO journal.

[27]  Nir Uriel,et al.  Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[28]  W. Cohn,et al.  Diaphragmatic implantation of the HeartWare ventricular assist device. , 2011, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[29]  D. D. Bois,et al.  CLINICAL CALORIMETRY: TENTH PAPER A FORMULA TO ESTIMATE THE APPROXIMATE SURFACE AREA IF HEIGHT AND WEIGHT BE KNOWN , 1916 .

[30]  Javier Bermejo,et al.  Contribution of the diastolic vortex ring to left ventricular filling. , 2014, Journal of the American College of Cardiology.

[31]  K. May-Newman,et al.  Thromboembolism Is Linked to Intraventricular Flow Stasis in a Patient Supported with a Left Ventricle Assist Device , 2013, ASAIO journal.

[32]  J. Stulak,et al.  In-hospital outcomes of a minimally invasive off-pump left thoracotomy approach using a centrifugal continuous-flow left ventricular assist device. , 2015, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[33]  Mohamed Amrani,et al.  De novo aortic regurgitation after continuous-flow left ventricular assist device implantation. , 2014, The Annals of thoracic surgery.

[34]  James O. Mudd,et al.  Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device. , 2008, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[35]  Andres Ceballos,et al.  Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk , 2013, Computer methods in biomechanics and biomedical engineering.

[36]  N. de Jonge,et al.  Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device. , 2013, Interactive cardiovascular and thoracic surgery.