Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo.

OBJECTIVES To compare reliability for landmark identification on patient images from three-dimensional (3D) cone beam CT (CBCT) and digital two-dimensional (2D) lateral cephalograms. METHODS Ten lateral cephalometric digital radiographs and their corresponding CBCT images were randomly selected. 27 observers digitally identified 27 landmarks in both modes. The x- and y-coordinates for each landmark, indicating the horizontal and vertical positions, were analysed for interobserver reliability by comparing each measurement to the best estimate of the true value. Intraobserver reliability was also assessed. Linear models and intraclass correlation coefficients (ICCs) were used for analyses. RESULTS For interobserver reliability, the following locations were farther from the best estimate for 2D than 3D: x-location in subspinale (A-point), anterior tip of the nasal spine (ANS), L1 lingual gingival border and L1 root; y-location in porion, ramus point and orbitale; x- and y-locations in basion, condylion, midramus, sigmoid notch and U6 occlusal. 3D y-locations were farther in the gonion, L1 tip, sella and U1 tip. For intraobserver reliability, 2D locations were farther in y-locations in orbitale and sigmoid notch, and both x- and y-locations in basion. 3D locations were farther in the x-location in U1 labial gingival border and y-locations in L1 tip, L6 occlusal, menton and sella. For intraobserver ICCs, greater variations in 2D than 3D included: A-point, ANS, midramus, orbitale, ramus point, sigmoid notch and U1 root. CONCLUSIONS 3D imaging, as in CBCT, allows for overall improved interobserver and intraobserver reliability in certain landmarks in vivo when compared with two-dimensional images.

[1]  Y J Chen,et al.  Comparison of landmark identification in traditional versus computer-aided digital cephalometry. , 2009, The Angle orthodontist.

[2]  J F Gravely,et al.  The Clinical Significance of Tracing Error in Cephalometry , 1974, British journal of orthodontics.

[3]  A Wenzel,et al.  Reliability of landmark recording on film and digital lateral cephalograms. , 1993, European journal of orthodontics.

[4]  L. Koenig,et al.  Cone beam volumetric tomography vs. medical CT scanners. , 2005, The New York state dental journal.

[5]  C. Gyldensted,et al.  Comparison of the Reliability of Craniofacial Anatomic Landmarks Based on Cephalometric Radiographs and Three-Dimensional CT Scans , 1997 .

[6]  B. Epker,et al.  Cephalometrics: a comparison of five analyses currently used in the diagnosis of dentofacial deformities. , 1987, International Journal of Adult Orthodontics and Orthognathic Surgery.

[7]  Haijo Jung,et al.  Quantitative evaluation of acquisition parameters in three-dimensional imaging with multidetector computed tomography using human skull phantom. , 2002, Journal of digital imaging.

[8]  A Richardson,et al.  A comparison of traditional and computerized methods of cephalometric analysis. , 1981, European journal of orthodontics.

[9]  Filip Schutyser,et al.  Three-dimensional cephalometry : a color atlas and manual , 2006 .

[10]  Sheldon Baumrind,et al.  The reliability of head film measurements , 1971 .

[11]  Alex Jacobson,et al.  Reliability of Digital Versus Conventional Cephalometric Radiology: A Comparative Evaluation of Landmark Identification Error , 2005 .

[12]  James Mah,et al.  3-D volume imaging for dentistry: a new dimension. , 2003, Journal of the California Dental Association.

[13]  J. Mah,et al.  Three-dimensional radiographic analysis in orthodontics. , 2005, Journal of clinical orthodontics.

[14]  T. M. Graber,et al.  An atlas and manual of cephalometric radiography , 1982 .

[15]  A. Kuijpers-Jagtman,et al.  Identification of Cephalometric Landmarks in Unilateral Cleft Lip and Palate Patients: Are There Alternatives for Point A, ANS, and PNS? , 2008, The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association.