Fixed-band fixed-frequency hysteresis current control used In APFs

A practical concern with implementing the fixed band hysteresis current control in active power filters (APF) is its variable switching pattern that results in increasing the risk of occurrence of resonance in power systems. To avoid this situation, adaptive hysteresis current control methods with the variable hysteresis bands have been recommended in literature. However, these methods impose an absolutely huge amount of complex computations on the system which, in turn, slows down its response time and thereby, limits the switching frequency. This paper devises a novel fixed-band fixed-frequency (FBFF) hysteresis current control strategy that aims to eliminate completely the mentioned calculations while keeps merits of the adaptive methods. In other words, the suggested strategy employs an algorithm that is similar to the fixed-band variable-frequency hysteresis methods; however, the outcomes are identical to the variable-band fixed-frequency hysteresis current control techniques. Employing the proposed FBFF method to control an APF leads to an accurate modulation performance with the least possible calculations required in a filtering procedure. Several simulations are done using MATLAB/Simulink to verify validity of the proposed method.

[1]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[2]  Mahesh K. Mishra,et al.  Design and Analysis of User-Defined Constant Switching Frequency Current-Control-Based Four-Leg DSTATCOM , 2009 .

[3]  Avik Bhattacharya,et al.  A Shunt Active Power Filter With Enhanced Performance Using ANN-Based Predictive and Adaptive Controllers , 2011, IEEE Transactions on Industrial Electronics.

[4]  Kamal Al-Haddad,et al.  A Lyapunov-Function-Based Control for a Three-Phase Shunt Hybrid Active Filter , 2012, IEEE Transactions on Industrial Electronics.

[5]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[6]  M. Tavakoli Bina,et al.  An efficient procedure to design passive LCL-filters for active power filters , 2009 .

[7]  B. Bose An adaptive hysteresis-band current control technique of a voltage-fed PWM inverter for machine drive system , 1990 .

[8]  Fangrui Liu,et al.  A Novel Variable Hysteresis Band Current Control of Three-Phase Three-Level Unity PF Rectifier With Constant Switching Frequency , 2006, IEEE Transactions on Power Electronics.

[9]  Frede Blaabjerg,et al.  Control in Power Electronics , 2002 .

[10]  Kamal Al-Haddad,et al.  Experimental Design of a Nonlinear Control Technique for Three-Phase Shunt Active Power Filter , 2010, IEEE Transactions on Industrial Electronics.

[11]  Hani Vahedi,et al.  Variable hysteresis current control applied in a shunt active filter with constant switching frequency , 2010, 2010 First Power Quality Conferance.

[12]  Hani Vahedi,et al.  A novel hysteresis bandwidth (NHB) calculation to fix the switching frequency employed in active power filter , 2011, 2011 IEEE Applied Power Electronics Colloquium (IAPEC).

[13]  Paolo Tomasin,et al.  Improved constant-frequency hysteresis current control of VSI inverters with simple feed-forward bandwidth prediction , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[14]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[15]  Hani Vahedi,et al.  Review and Simulation of Fixed and Adaptive Hysteresis Current Control Considering Switching Losses and High-Frequency Harmonics , 2011 .

[16]  Kamal Al-Haddad,et al.  A review of three-phase improved power quality AC-DC converters , 2003, IEEE Transactions on Industrial Electronics.