Osseointegration of a hydroxyapatite-coated multilayered mesh stem.

A new type of porous coating for hip prostheses called "multilayered mesh" was tested under weight-bearing conditions. The surface of the stem is constructed of titanium mesh produced by etching. The hip stems of hydroxyapatite (HA)-coated multilayered mesh and conventional beads were implanted into canine right hips, and animals were killed 3, 6 and 10 weeks and 6 and 12 months after implantation. Shear strength between the implant and the bone was evaluated by the push-out test. Bone ingrowth was calculated from backscattered electron imaging-scanning electron microscopy (BEI-SEM) images of transverse sections. Toluidine blue stained sections and the BEI-SEM images were evaluated histologically. The break sites of the specimens after the push-out test were evaluated on BEI-SEM images of longitudinal sections. The mean push-out strength of the HA-coated multilayered mesh samples was greater than that of the beads-coated samples every time tested, and the HA-coated multilayered mesh implants had significantly stronger push-out strength at 3 and 6 weeks (p<0.05). The strength of the HA-coated multilayered mesh implants was even greater at 6 and 12 months, whereas the strength of the beads-coated samples decreased. The HA-coated multilayered mesh implants showed significantly higher percentages of bone ingrowth than the beads-coated implants every time tested, except at 6 months (p<0.05). At 6 and 12 months, the bone ingrowth data for the HA-coated multilayered mesh implants increased, whereas it decreased for the beads-coated implants. The new bone formation had reached the bottom of the porous area of the HA-coated multilayered mesh surface by 3 weeks, but not had reached the bottom of the conventional beads surface. At 6 and 12 months, the smaller pores of the bead surface stopped the thickening of trabecular bone, and at 12 months, the break sites were at the bone-implant interface of the bead surface, whereas they were on the bone side of the HA-coated multilayered mesh surface. The difference between the break sites was significant at 12 months (p<0.05). The HA-coated multilayered mesh stem provided faster, stronger, and more durable osseointegration than the conventional bead stem.

[1]  R. Pilliar,et al.  Characterization of the interface in the plasma-sprayed HA coating/Ti-6Al-4V implant system. , 1991, Journal of biomedical materials research.

[2]  W R Walsh,et al.  Morphometric and mechanical evaluation of titanium implant integration: comparison of five surface structures. , 2000, Journal of biomedical materials research.

[3]  C. Ranawat,et al.  Hydroxyapatite: catalyst or conjuror? , 2002, The Journal of arthroplasty.

[4]  K. Khor,et al.  Titanium dioxide reinforced hydroxyapatite coatings deposited by high velocity oxy-fuel (HVOF) spray. , 2002, Biomaterials.

[5]  O. Takai,et al.  Effects of ion concentration and pH on hydroxyapatite deposition from aqueous solution onto titanium by the thermal substrate method. , 2002, Journal of biomedical materials research.

[6]  K. Hayashi,et al.  Hydroxyapatite-coating on titanium arc sprayed titanium implants. , 1997, Journal of biomedical materials research.

[7]  L. Hench,et al.  CRC handbook of bioactive ceramics , 1990 .

[8]  P. Rozing,et al.  A finite element analysis of the push-out test: influence of test conditions. , 1992, Journal of biomedical materials research.

[9]  P. Ducheyne,et al.  The effect of plasma-sprayed calcium phosphate ceramic coatings on the metal ion release from porous titanium and cobalt-chromium alloys. , 1988, Journal of biomedical materials research.

[10]  R M Pilliar,et al.  The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. , 1980, Clinical orthopaedics and related research.

[11]  L. Dorr,et al.  The effect of diaphyseal biologic fixation on clinical results and fixation of the APR-II stem. , 2000, The Journal of arthroplasty.

[12]  D. Berry,et al.  Long-Term Results of Use of a Collared Matte-Finished Femoral Component Fixed with Second-Generation Cementing Techniques: A Fifteen-Year-Median Follow-up Study , 2002, The Journal of bone and joint surgery. American volume.

[13]  J. Bellemans Osseointegration in porous coated knee arthroplasty. The influence of component coating type in sheep. , 1999, Acta orthopaedica Scandinavica. Supplementum.

[14]  S. Cook,et al.  The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants. , 1995, The Journal of bone and joint surgery. American volume.

[15]  A I Caplan,et al.  Stem cell technology and bioceramics: from cell to gene engineering. , 1999, Journal of biomedical materials research.

[16]  H. Cameron Bone Implant Interface , 1994 .

[17]  A. Edidin,et al.  Fixation of Acetabular Cups without Cement in Total Hip Arthroplasty. A Comparison of Three Different Implant Surfaces at a Minimum Duration of Follow-up of Five Years* , 1998, The Journal of bone and joint surgery. American volume.

[18]  J. Jansen,et al.  Effect of calcium phosphate coating crystallinity and implant surface roughness on differentiation of rat bone marrow cells. , 2002, Journal of biomedical materials research.

[19]  J. Galante,et al.  A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model. , 1986, The Journal of bone and joint surgery. American volume.

[20]  P. Herberts,et al.  Porous cups with and without hydroxylapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry. , 1999, The Journal of arthroplasty.

[21]  O. Takai,et al.  Hydroxyapatite coating on titanium by thermal substrate method in aqueous solution. , 2002, Journal of biomedical materials research.

[22]  S D Cook,et al.  Hydroxylapatite coating of porous implants improves bone ingrowth and interface attachment strength. , 1992, Journal of biomedical materials research.

[23]  D. Hungerford,et al.  Proximally porous-coated ingrowth prostheses: limits of use. , 1999, Orthopedics.

[24]  S. Mirov,et al.  Structural and morphological study of pulsed laser deposited calcium phosphate bioceramic coatings: influence of deposition conditions, laser parameters, and target properties. , 2000, Journal of biomedical materials research.

[25]  J. Bechtold,et al.  Loading improves anchorage of hydroxyapatite implants more than titanium implants. , 2001, Journal of biomedical materials research.

[26]  D. Davy,et al.  Effects of hydroxyapatite tricalcium phosphate coating and intracancellous placement on bone ingrowth in titanium fibermetal implants. , 1995, The Journal of arthroplasty.

[27]  J. Galante,et al.  Enhancement of bone ingrowth by transforming growth factor-beta. , 1995, The Journal of bone and joint surgery. American volume.

[28]  F. Brossa,et al.  The relevance of hydroxyapatite and spongious titanium coatings in fixation of cementless stems , 1998, Archives of Orthopaedic and Trauma Surgery.

[29]  Yong Han,et al.  Evaluation of nanostructured carbonated hydroxyapatite coatings formed by a hybrid process of plasma spraying and hydrothermal synthesis. , 2002, Journal of biomedical materials research.

[30]  Paul Ducheyne,et al.  Bioceramics: material characteristics versus in vivo behavior. , 1987, Journal of biomedical materials research.

[31]  M. Freeman,et al.  The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant. , 1991, The Journal of arthroplasty.

[32]  J. Ricci,et al.  A new canine model to evaluate the biological response of intramedullary bone to implant materials and surfaces. , 1990, Journal of biomedical materials research.

[33]  S D Cook,et al.  Interface mechanics and histology of titanium and hydroxylapatite-coated titanium for dental implant applications. , 1987, The International journal of oral & maxillofacial implants.

[34]  F. Cui,et al.  High-resolution transmission electron microscopy investigations of a highly adhesive hydroxyapatite coating/titanium interface fabricated by ion-beam-assisted deposition. , 2000, Journal of biomedical materials research.

[35]  I. Hvid,et al.  Fixation of titanium and hydroxyapatite-coated implants in arthritic osteopenic bone. , 1991, The Journal of arthroplasty.

[36]  Y. Kameshima,et al.  Comparitive study of the formation of hydroxyapatite in simulated body fluid under static and flowing systems. , 2002, Journal of biomedical materials research.

[37]  N P Haas,et al.  Bone morphogenetic protein-2 coating of titanium implants increases biomechanical strength and accelerates bone remodeling in fracture treatment: a biomechanical and histological study in rats. , 2002, Bone.

[38]  M. Zimmerman,et al.  Three-dimensional printing and porous metallic surfaces: a new orthopedic application. , 2001, Journal of biomedical materials research.

[39]  S D Cook,et al.  An evaluation of variables influencing implant fixation by direct bone apposition. , 1985, Journal of biomedical materials research.

[40]  T. Albrektsson,et al.  Osteoinduction, osteoconduction and osseointegration , 2001, European Spine Journal.

[41]  K A Gross,et al.  Thermal processing of hydroxyapatite for coating production. , 1998, Journal of biomedical materials research.

[42]  H. N. Cheang,et al.  Surface characteristics and dissolution behavior of plasma-sprayed hydroxyapatite coating. , 2002, Journal of biomedical materials research.

[43]  S. Ding,et al.  Immersion behavior of RF magnetron-assisted sputtered hydroxyapatite/titanium coatings in simulated body fluid. , 1999, Journal of biomedical materials research.

[44]  K. Hong,et al.  Osteoconduction at porous hydroxyapatite with various pore configurations. , 2000, Biomaterials.

[45]  S D Cook,et al.  Hydroxyapatite-coated titanium for orthopedic implant applications. , 1988, Clinical orthopaedics and related research.

[46]  S. Tao,et al.  Effect of vapor-flame treatment on plasma sprayed hydroxyapatite coatings. , 2000, Journal of biomedical materials research.

[47]  R. Barrack,et al.  Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. , 1992, The Journal of bone and joint surgery. British volume.

[48]  H. Oonishi,et al.  The effect of hydroxyapatite coating on bone growth into porous titanium alloy implants. , 1989, The Journal of bone and joint surgery. British volume.

[49]  S D Cook,et al.  Hydroxyapatite-coated porous titanium for use as an orthopedic biologic attachment system. , 1988, Clinical orthopaedics and related research.

[50]  K. Chittur,et al.  Analytical and mechanical testing of high velocity oxy-fuel thermal sprayed and plasma sprayed calcium phosphate coatings. , 1999, Journal of biomedical materials research.

[51]  H. M. Kim,et al.  Bioactive macroporous titanium surface layer on titanium substrate. , 2000, Journal of biomedical materials research.

[52]  John A Jansen,et al.  Bone formation in transforming growth factor beta-I-loaded titanium fiber mesh implants. , 2002, Clinical oral implants research.

[53]  S. Cook,et al.  Tissue response to porous-coated implants lacking initial bone apposition. , 1988, The Journal of arthroplasty.

[54]  P. Ducheyne,et al.  Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants. , 1977, Journal of biomedical materials research.

[55]  J. Galante,et al.  The Bone-Implant Interface of Femoral Stems with Non-Circumferential Porous Coating. A Study of Specimens Retrieved at Autopsy* , 1996, The Journal of bone and joint surgery. American volume.

[56]  D. Hungerford,et al.  The rationale for cementless total hip replacement. , 1993, The Orthopedic clinics of North America.

[57]  R. German Powder metallurgy science , 1984 .

[58]  D. R. Sumner,et al.  Measuring the volume fraction of bone ingrowth: A comparison of three techniques , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[59]  D. Chappard,et al.  Free radicals and side products released during methylmethacrylate polymerization are cytotoxic for osteoblastic cells. , 1998, Journal of biomedical materials research.

[60]  W. Capello,et al.  Hydroxyapatite-Coated Total Hip Femoral Components in Patients Less Than Fifty Years Old. Clinical and Radiographic Results after Five to Eight Years of Follow-up* , 1997, The Journal of bone and joint surgery. American volume.

[61]  S. Downes,et al.  Osteoblast cell death on methacrylate polymers involves apoptosis. , 2001, Journal of biomedical materials research.

[62]  I. Noda,et al.  The development of new titanium arc-sprayed artificial joints , 1995 .

[63]  D. Shi,et al.  The effect of structural characteristics on the in vitro bioactivity of hydroxyapatite. , 2002, Journal of biomedical materials research.

[64]  G. Steiner,et al.  Interface-mediated synthesis of hydroxyapatite. , 2002, Journal of biomedical materials research.

[65]  J. B. Park,et al.  Biomechanical and morphometric analysis of hydroxyapatite-coated implants with varying crystallinity. , 1999, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[66]  K. Donath,et al.  Interface between bone tissue and implants of solid hydroxyapatite or hydroxyapatite-coated titanium implants. , 1989, Biomaterials.

[67]  Kay Jf Calcium phosphate coatings for dental implants. Current status and future potential. , 1992 .

[68]  J. Galante,et al.  Fiber metal composites in the fixation of skeletal prosthesis. , 1973, Journal of biomedical materials research.

[69]  Mansur Ahmad,et al.  Effects of transforming growth factor-beta 1 (TGF-beta1) on in vitro mineralization of human osteoblasts on implant materials. , 2003, Biomaterials.

[70]  H. M. Kim,et al.  TEM-EDX study of mechanism of bonelike apatite formation on bioactive titanium metal in simulated body fluid. , 2001, Journal of biomedical materials research.

[71]  W. Capello,et al.  Hydroxyapatite in Total Hip Arthroplasty: Clinical Results and Critical Issues , 1998, Clinical orthopaedics and related research.

[72]  E. Sachs,et al.  Design and fabrication of cast orthopedic implants with freeform surface textures from 3-D printed ceramic shell. , 2000, Journal of biomedical materials research.

[73]  C. Bünger,et al.  Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit. , 1990, Acta orthopaedica Scandinavica.

[74]  W. Maloney,et al.  Ingrowth of bone in failed fixation of porous-coated femoral components. , 1991, The Journal of bone and joint surgery. American volume.

[75]  S. Tor,et al.  In vitro behavior of sintered powder injection molded Ti-6Al-4V/HA. , 2002, Journal of biomedical materials research.

[76]  Y. Leng,et al.  In vitro mechanical integrity of hydroxyapatite coatings on Ti-6Al-4V implants under shear loading. , 2001, Journal of biomedical materials research.

[77]  L. Palm,et al.  Hydroxyapatite coating improves 8- to 10-year performance of the link RS cementless femoral stem. , 2002, The Journal of arthroplasty.

[78]  Takashi Nakamura,et al.  Effect of water treatment on the apatite-forming ability of NaOH-treated titanium metal. , 2002, Journal of biomedical materials research.

[79]  R.G.T. Geesink,et al.  Osteoconductive Coatings for Total Joint Arthroplasty , 2002, Clinical orthopaedics and related research.

[80]  K. Hayashi,et al.  Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. , 1994, Biomaterials.

[81]  C. Klein,et al.  Plasma sprayed coatings of hydroxylapatite. , 1987, Journal of biomedical materials research.

[82]  J. Déjou,et al.  The biodegradation mechanism of calcium phosphate biomaterials in bone. , 2002, Journal of biomedical materials research.

[83]  L. Dorr,et al.  Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation. , 1998, The Journal of arthroplasty.