Natural convection effects on heat and mass transfer in a curvilinear triangular cavity

Abstract Finite element method is used in this study to analyze the effects of buoyancy ratio and Lewis number on heat and mass transfer in a triangular cavity with zig-zag shaped bottom wall. Buoyancy ratio is defined as the ratio of Grashof number of solutal and thermal. Inclined walls of the cavity have lower temperature and concentration according to zig-zag shaped bottom wall. Enclosed space consists mostly of an absorber plate and two inclined glass covers that form a cavity. Both high temperature and high concentrations are applied to bottom corrugated wall. Computations were done for different values of buoyancy ratio (−10 ⩽ Br ⩽ 10), Lewis number (0.1 ⩽ Le ⩽ 20) and thermal Rayleigh number (104 ⩽ RaT ⩽ 106). Streamlines, isotherms, iso-concentration, average Nusselt and Sherwood numbers are obtained. It is found that average Nusselt and Sherwood numbers increase by 89.18% and 101.91% respectively as Br increases from −10 to 20 at RaT = 106. Also, average Nusselt decreases by 16.22% and Sherwood numbers increases by 144.84% as Le increases from 0.1 to 20 at this Rayleigh number.

[1]  R. D. Flack,et al.  The Experimental Measurement of Natural Convection Heat Transfer in Triangular Enclosures Heated or Cooled from Below , 1980 .

[2]  P. Kandaswamy,et al.  Double Diffusive Convection of Water in a Rectangular Partitioned Enclosure with Temperature Dependent Species Diffusivity , 2006 .

[3]  S. B. Nasrallah,et al.  A numerical model for the simulation of double-diffusive natural convection in a triangular cavity using equal order and control volume based on the finite element method , 2007 .

[4]  A. Omri Numerical investigation on optimization of a solar distiller dimensions , 2007 .

[5]  Dimos Poulikakos,et al.  The fluid dynamics of an attic space , 1983, Journal of Fluid Mechanics.

[6]  Haydee Salmun,et al.  Convection patterns in a triangular domain , 1995 .

[7]  T. Nishimura,et al.  Oscillatory double-diffusive convection in a rectangular enclosure with combined horizontal temperature and concentration gradients , 1998 .

[8]  L. Namli,et al.  Laminar natural convection in a pitched roof of triangular cross-section: summer day boundary conditions , 2000 .

[9]  Antonio Campo,et al.  Benefits Derivable from Connecting the Bottom and Top Walls of Attic Enclosures with Insulated Vertical Side Walls , 2006 .

[10]  Fariborz Haghighat,et al.  Numerical study of double-diffusive natural convection in a square cavity , 1992 .

[11]  Ruey-Jen Yang,et al.  Double diffusive natural convection in a partially heated enclosure with Soret and Dufour effects , 2009 .

[12]  I. Pop,et al.  Influence of inclination angle on buoyancy-driven convection in triangular enclosure filled with a fluid-saturated porous medium , 2008 .

[13]  R. Bennacer,et al.  Cooperating thermosolutal convection in enclosures—I. Scale analysis and mass transfer , 1996 .

[14]  Ali J. Chamkha,et al.  Double-diffusive natural convection in inclined finned triangular porous enclosures in the presence of heat generation/absorption effects , 2010 .

[15]  Nasrudin Abd Rahim,et al.  Conjugated effect of joule heating and magneto-hydrodynamic on double-diffusive mixed convection in a horizontal channel with an open cavity , 2011 .

[16]  Y. Varol,et al.  Natural convection in a triangle enclosure with flush mounted heater on the wall , 2006 .

[17]  D. Gobin,et al.  Cooperating thermosolutal convection in enclosures—II. Heat transfer and flow structure , 1996 .

[18]  M. Sen,et al.  ANALYSIS OF LAMINAR NATURAL CONVECTION IN A TRIANGULAR ENCLOSURE , 1988 .

[19]  J. Orfi,et al.  Natural convection effects in solar stills , 2005 .

[20]  L. Namli,et al.  Numerical simulation of buoyant flow in a roof of triangular cross-section under winter day boundary conditions , 2001 .

[21]  Saiied M. Aminossadati,et al.  Mixed convection in a lid-driven triangular enclosure filled with nanofluids , 2010 .

[22]  Ioan Pop,et al.  Entropy generation due to natural convection in non-uniformly heated porous isosceles triangular enclosures at different positions , 2009 .

[23]  E. Fuad Kent,et al.  Numerical analysis of laminar natural convection in isosceles triangular enclosures for cold base and hot inclined walls , 2009 .

[24]  Ahmet Koca,et al.  The effects of Prandtl number on natural convection in triangular enclosures with localized heating from below , 2007 .

[25]  I. Sezai,et al.  Double diffusive convection in a cubic enclosure with opposing temperature and concentration gradients , 2000 .

[26]  Dimos Poulikakos,et al.  Natural Convection Experiments in a Triangular Enclosure , 1983 .

[27]  Suvash C. Saha,et al.  A review of natural convection and heat transfer in attic-shaped space , 2011 .