Multiple model approach and experimental validation of a residential air-to-air heat pump

The beginning of this work is the achievement of a design tool, which is a multiple model software called " CODYRUN ", suitable for professionnals and usable by researchers. The original aspect of this software is that the designer has at his disposal a wide panel of choices between different heat transfer models More precisely, it consists in a multizone software integrating both natural ventilation and moisture tranfers . This software is developed on PC micro computer and gets advantage of the Microsoft WINDOWS front-end. Most of time, HVAC systems and specially domestic air conditioners, are taken into account in a very simplified way, or in a elaborated one. On one side,they are just supposed to supply the demand of cooling loads with an ideal control loop (no delay between the sollicitations and the time response of the system), The available outputs are initially the hourly cooling and heating consumptions without integrating the real caracteristics of the HVAC system This paper is also following the same multiple model approach than for the building modelling by defining different modelling levels for the air conditionning systems, from a very simplified one to a detailled one. An experimental validation is achieved in order to compare the sensitivity of each defined model and to point out the interaction between the thermal behaviour of the envelop and the electrical system consumption. For validation purposes, we will describe the data acquisition system. and the used real size test cell located in the University of Reunion island, Indian Ocean.

[1]  W. J. Mulroy The effect of short cycling and fan delay on the efficiency of a modified residential heat pump , 1986 .

[2]  E. W. Grald,et al.  Prediction of cyclic heat pump performance with a fully distributed model and a comparison with experimental data , 1987 .

[3]  S. J. Irving APACHE—an integrated approach to thermal and HVAC systems analysis , 1986 .

[4]  S. Devotta,et al.  Steady- and dynamic-state simulations of heat-pumps. Part III: Comparison between predictions and measurements , 1989 .

[5]  Joseph Andrew Clarke,et al.  Energy Simulation in Building Design , 1985 .

[6]  S. Devotta,et al.  Steady- and dynamic-state simulations of heat-pumps. Part I: Literature review , 1988 .

[7]  Harry Boyer,et al.  Multiple model software for airflow and thermal building simulation. A case study under tropical humid climate, in Réunion Island , 2012, ArXiv.

[8]  R. R. Crawford,et al.  Dynamic modeling of a residential heat pump from actual system performance data , 1987 .

[9]  N. Galanis,et al.  Prediction of the transient response of heat pumps , 1987 .

[10]  Brigitte Grondin-Perez,et al.  Thermal Building Simulation and Computer Generation of Nodal Models , 2012, ArXiv.

[11]  David Didion,et al.  Refrigerant Migration in a Split-Unit Air Conditioner | NIST , 1985 .

[12]  J. J. Hirsch SIMULATION OF HVAC EQUIPMENT IN THE DOE-2 PROGRAM , 1982 .

[13]  D. Didion,et al.  A simulation model of the transient performance of a heat pump , 1982 .

[14]  STRUCTURATION INDUCED FOR BUILDING THERMAL SIMULATION CODES , 2012 .

[15]  Harry Boyer,et al.  Validation expérimentale d'un code de modélisation thermique de bâtiments (CODYRUN). Une application en climat tropical humide. , 1995 .