CYBERLEGs: A User-Oriented Robotic Transfemoral Prosthesis with Whole-Body Awareness Control

Restoring the mobility of transfemoral dysvascular amputees is essential to their rehabilitation process. Impeding the restoration of mobility, exhaustion is often the cause of noneffective deambulation of elderly lowerlimb amputees using a prosthesis as they use more energy for locomotion than younger amputees do. This article presents finite-state control of a novel powered prosthesis prototype for transfemoral amputees based on whole-body awareness. Intention detection was implemented through a noninvasive, distributed wireless wearable sensory system. The cybernetic lower-limb cognitive orthoprosthesis (CYBERLEGs) system was evaluated in a study involving three amputees. The subjects were able to walk with the prosthesis without training, showing accurate performance of the intention detection. The functionality of the CYBERLEGs approach was confirmed by gait pattern analysis and intention detection statistics.

[1]  R. Waters,et al.  Energy cost of walking of amputees: the influence of level of amputation. , 1976, The Journal of bone and joint surgery. American volume.

[2]  Robert D. Lipschutz,et al.  Robotic leg control with EMG decoding in an amputee with nerve transfers. , 2013, The New England journal of medicine.

[3]  Akin O. Kapti,et al.  Design and control of an active artificial knee joint , 2006 .

[4]  Hugh Herr,et al.  Agonist-antagonist active knee prosthesis: a preliminary study in level-ground walking. , 2009, Journal of rehabilitation research and development.

[5]  Lauren H Smith,et al.  A comparison of the real-time controllability of pattern recognition to conventional myoelectric control for discrete and simultaneous movements , 2012, Journal of NeuroEngineering and Rehabilitation.

[6]  Bram Vanderborght,et al.  MACCEPA, the mechanically adjustable compliance and controllable equilibrium position actuator: Design and implementation in a biped robot , 2007, Robotics Auton. Syst..

[7]  Marko Munih,et al.  Development and validation of a wearable inertial measurement system for use with lower limb exoskeletons , 2011, 2011 11th IEEE-RAS International Conference on Humanoid Robots.

[8]  R Jiménez-Fabián,et al.  Review of control algorithms for robotic ankle systems in lower-limb orthoses, prostheses, and exoskeletons. , 2012, Medical engineering & physics.

[9]  Michael Goldfarb,et al.  Design and Control of a Powered Transfemoral Prosthesis , 2008, Int. J. Robotics Res..

[10]  Joan E Sanders,et al.  Transtibial energy-storage-and-return prosthetic devices: a review of energy concepts and a proposed nomenclature. , 2002, Journal of rehabilitation research and development.

[11]  Hugh M. Herr,et al.  Powered ankle-foot prosthesis , 2008, IEEE Robotics & Automation Magazine.

[12]  T.G. Sugar,et al.  SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[13]  F Franchignoni,et al.  Trinity Amputation and Prosthesis Experience Scales: A Psychometric Assessment Using Classical Test Theory and Rasch Analysis , 2010, American journal of physical medicine & rehabilitation.

[14]  Michael Goldfarb,et al.  Design and Control of a Powered Knee and Ankle Prosthesis , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[15]  E. Mackenzie,et al.  Epidemiology of limb loss and congenital limb deficiency: a review of the literature. , 2003, Archives of physical medicine and rehabilitation.

[16]  Joost Geeroms,et al.  Ankle-Knee prosthesis with powered ankle and energy transfer for CYBERLEGs α-prototype , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[17]  Robert D. Lipschutz,et al.  Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. , 2009, JAMA.

[18]  H. Alaranta,et al.  Prosthetic use and functional and social outcome following major lower limb amputation , 1990, Prosthetics and orthotics international.

[19]  Thomas G. Sugar,et al.  The SPARKy (Spring Ankle With Regenerative Kinetics) Project: Design and Analysis of a Robotic Transtibial Prosthesis With Regenerative Kinetics , 2007 .

[20]  Bram Vanderborght,et al.  Design and Validation of the Ankle Mimicking Prosthetic (AMP-) Foot 2.0 , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[21]  Nigel H. Lovell,et al.  Accelerometry based classification of gait patterns using empirical mode decomposition , 2008, 2008 IEEE International Conference on Acoustics, Speech and Signal Processing.

[22]  R W Mann,et al.  An electrohydraulic knee-torque controller for a prosthesis simulator. , 1977, Journal of biomechanical engineering.

[23]  H.A. Varol,et al.  Real-time Intent Recognition for a Powered Knee and Ankle Transfemoral Prosthesis , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[24]  Liam Kilmartin,et al.  Optimising recognition rates for subject independent gait pattern classification , 2009 .

[25]  Simona Crea,et al.  A Wireless Flexible Sensorized Insole for Gait Analysis , 2014, Sensors.

[26]  Nicola Vitiello,et al.  Automated detection of gait initiation and termination using wearable sensors. , 2013, Medical engineering & physics.

[27]  Roman Kamnik,et al.  Kinematics based sensory fusion for wearable motion assessment in human walking , 2014, Comput. Methods Programs Biomed..

[28]  Guido Pasquini,et al.  Online Phase Detection Using Wearable Sensors for Walking with a Robotic Prosthesis , 2014, Sensors.