Wear performance of dental ceramics after grinding and polishing treatments.

AIM The aim of this in vitro study was to determine the two-body wear resistance of different dental ceramics after grinding and polishing treatments. MATERIAL AND METHODS Standardized specimens were prepared from three zirconia and two veneering ceramics and were subjected to different surface treatments. Zirconia ceramics were polished, ground and repolished, veneering ceramics were ground and repolished. One zirconia ceramic was investigated with a superficial glaze. Human enamel was used for reference. Surface roughness R(a) was determined using a profilometric contact surface measurement device. Two-body wear tests were performed in a chewing simulator with steatite and enamel antagonists, respectively. Specimens were loaded pneumatically in a pin-on-block design for 1.2x10(5) mastication cycles (50 N, 1.2 Hz, lateral movement: 1 mm, mouth opening: 2 mm) under simultaneous thermal cycling (600 cycles, 5/55 °C). Wear depths of specimens were determined using a 3D laser scanning device, wear areas of steatite antagonists were measured by means of light-optical micrographs. Means and standard deviations were calculated, and statistical analysis was performed using one-way analysis of variance (ANOVA) and the Bonferroni multiple comparison test for post hoc analysis (α=0.05). Scanning electron microscopy was applied for evaluating the wear performance of ceramics and antagonists. RESULTS No wear was found for polished, ground and repolished zirconia. Compared to the wear depths of the enamel reference with 274.1±187.4 μm versus steatite and 123.3±131.0 μm versus enamel, relative wear depths of porcelains ranged between 0.54±0.07 and 0.62±0.09 with steatite antagonists and between 0.66±0.26 and 1.04±0.27 with enamel antagonists. Relative wear areas of steatite antagonists (enamel reference: 1.25 mm(2)) varied between 0.84±0.13 and 1.90±0.29 for zirconia and between 1.97±0.38 and 2.47±0.40 for porcelains. Enamel antagonists generally showed wear, cracks or even fractures, but revealed smooth surfaces when opposed to polished/ground/repolished zirconia and ploughed surfaces when opposed to ground/repolished porcelains or glaze. CONCLUSIONS Zirconia ceramics yielded superior wear behavior and lower antagonistic wear compared to porcelains. A trend to higher ceramic and antagonistic wear was shown after grinding treatments.

[1]  H. Fischer,et al.  Effect of Surface Roughness on Flexural Strength of Veneer Ceramics , 2003, Journal of dental research.

[2]  K. Anusavice,et al.  Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[3]  Michael V Swain,et al.  Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[4]  E. D. Rekow,et al.  Concerns of Hydrothermal Degradation in CAD/CAM Zirconia , 2010, Journal of dental research.

[5]  C. Larsson Zirconium dioxide based dental restorations : studies on clinical survival and fracture behaviour , 2011 .

[6]  V. Thompson,et al.  Sliding Contact Fatigue Damage in Layered Ceramic Structures , 2007, Journal of dental research.

[7]  M. Yoshimura,et al.  Phase stability of zirconia , 1988 .

[8]  Sang‐Wan Shin,et al.  A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain , 2010, The journal of advanced prosthodontics.

[9]  M. Behr,et al.  Two-body wear of artificial acrylic and composite resin teeth in relation to antagonist material. , 2009, The Journal of prosthetic dentistry.

[10]  S. Holst,et al.  Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis. , 2011, Journal.

[11]  H. Yılmaz,et al.  Influence of surface treatments on surface roughness, phase transformation, and biaxial flexural strength of Y-TZP ceramics. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[12]  I. Krejci,et al.  Wear of ceramic inlays, their enamel antagonists, and luting cements. , 1993, The Journal of prosthetic dentistry.

[13]  M. Rosentritt,et al.  Wear Performance of Dental Materials: A Comparison of Substructure Ceramics, Veneering Ceramics, and Non‐Precious Alloys , 2011 .

[14]  G. Carlsson,et al.  Covariation of some factors associated with occlusal tooth wear in a selected high-wear sample. , 1993, Scandinavian journal of dental research.

[15]  S. Dunne,et al.  Quantitative measurement of tooth and ceramic wear: in vivo study. , 2008, The International journal of prosthodontics.

[16]  P. Lambrechts,et al.  Quantitative in vivo Wear of Human Enamel , 1989, Journal of dental research.

[17]  Irena Sailer,et al.  Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. , 2009, The International journal of prosthodontics.

[18]  R. Wassell,et al.  Wear characteristics in a two-body wear test. , 1994, Dental materials : official publication of the Academy of Dental Materials.

[19]  Berit I Ardlin,et al.  Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of low-temperature aging on flexural strength and surface structure. , 2002, Dental materials : official publication of the Academy of Dental Materials.

[20]  S. Ringer,et al.  Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part I. Pressable and alumina glass-infiltrated ceramics. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[21]  S. Heintze How to qualify and validate wear simulation devices and methods. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[22]  V. Rousson,et al.  Wear of ceramic and antagonist--a systematic evaluation of influencing factors in vitro. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[23]  M. Behr,et al.  Wear performance of substructure ceramics and veneering porcelains. , 2011, Dental materials : official publication of the Academy of Dental Materials.

[24]  S. Koutayas,et al.  Zirconia in dentistry: Part 1. Discovering the nature of an upcoming bioceramic. , 2009, The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry.

[25]  P. Marquis,et al.  Potential countersample materials for in vitro simulation wear testing. , 2002, Dental materials : official publication of the Academy of Dental Materials.

[26]  T. Stolarski,et al.  Wear: mechanisms, manifestations and measurement. Report of a workshop. , 1996, Journal of dentistry.

[27]  W H Gilmour,et al.  Investigation of human enamel wear against four dental ceramics and gold. , 1998, Journal of dentistry.

[28]  K Lyons,et al.  Clinical trials in zirconia: a systematic review. , 2010, Journal of oral rehabilitation.

[29]  P Cloetens,et al.  Monoclinic phase transformations of zirconia-based dental prostheses, induced by clinically practised surface manipulations. , 2011, Acta biomaterialia.

[30]  J. Chevalier,et al.  Critical effect of cubic phase on aging in 3mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis. , 2004, Biomaterials.

[31]  B H Miller,et al.  In vitro investigation of the wear of human enamel by dental porcelain. , 1999, The Journal of prosthetic dentistry.

[32]  M. Behr,et al.  Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures , 2011, Clinical Oral Investigations.

[33]  I. Krejci,et al.  The Influence of Antagonist Standardization on Wear , 1999, Journal of dental research.

[34]  B. Lawn,et al.  Lifetime-limiting Strength Degradation from Contact Fatigue in Dental Ceramics , 2000, Journal of dental research.

[35]  S. Heo,et al.  A study of the effects of chewing patterns on occlusal wear. , 2001, Journal of oral rehabilitation.

[36]  B. Lawn,et al.  Deep-penetrating conical cracks in brittle layers from hydraulic cyclic contact. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[37]  Wei Li,et al.  Effects of sintering temperature and particle size on the translucency of zirconium dioxide dental ceramic , 2011, Journal of materials science. Materials in medicine.

[38]  M Rosentritt,et al.  Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[39]  M. Behr,et al.  Two-body wear of dental porcelain and substructure oxide ceramics , 2011, Clinical Oral Investigations.

[40]  Martin Rosentritt,et al.  Approach for valuating the influence of laboratory simulation. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[41]  L H Mair,et al.  Wear in dentistry--current terminology. , 1992, Journal of dentistry.

[42]  R. Wassell,et al.  A Two-body Frictional Wear Test , 1994, Journal of dental research.

[43]  J L Ferracane,et al.  In vitro Wear of Composite with Varied Cure, Filler Level, and Filler Treatment , 1997, Journal of dental research.

[44]  K J Anusavice,et al.  Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics. , 2000, Journal of dentistry.

[45]  Won-Suck Oh,et al.  Factors affecting enamel and ceramic wear: a literature review. , 2002, The Journal of prosthetic dentistry.

[46]  M. Behr,et al.  Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. , 2009, Journal of dentistry.

[47]  V. Rousson,et al.  Recommendations for conducting controlled clinical studies of dental restorative materials , 2007, Clinical Oral Investigations.

[48]  K. Anusavice,et al.  In vivo wear of enamel by a lithia disilicate-based core ceramic used for posterior fixed partial dentures: first-year results. , 2006, The International journal of prosthodontics.

[49]  G. Carlsson,et al.  An investigation of some factors associated with occlusal tooth wear in a selected high-wear sample. , 1993, Scandinavian journal of dental research.

[50]  E. D. Rekow,et al.  Laboratory Simulation of Y-TZP All-ceramic Crown Clinical Failures , 2009, Journal of dental research.