A chronopotentiometric approach for measuring chloride ion concentration

In this paper, a novel approach is reported for the electrochemical measurement of chloride ions in aqueous solution. This sensor is based on the stimulus/response principle of chronopotentiometry. A current pulse is applied at the Ag/AgCl working electrode and the potential change is measured with respect to another identical Ag/AgCl electrode in the bulk electrolyte. The potential difference is related to the Cl- ion concentration via the Nernst equation and follows an inverse logarithmic trend. By varying the applied current pulse, the sensitivity of the sensor is tunable to different concentration ranges. The potential response is also influenced by the pH of the electrolyte, this effect is pronounced at lower concentration of Cl- ions ( 12 pH). The advantage of this approach is the use of a bare Ag/AgCl electrode as a pseudo-reference electrode, which enables this system for long term application such as the in situ measurement of ClE‰ ions in concrete

[1]  A. Michalska,et al.  All-solid-state planar miniature ion-selective chloride electrode , 2002 .

[2]  C. Page,et al.  Aspects of the electrochemistry of steel in concrete , 1982, Nature.

[3]  E. Bakker,et al.  Calcium pulstrodes with 10-fold enhanced sensitivity for measurements in the physiological concentration range. , 2006, Analytical chemistry.

[4]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[6]  M. Montemor,et al.  CHLORIDE-INDUCED CORROSION ON REINFORCING STEEL: FROM THE FUNDAMENTALS TO THE MONITORING TECHNIQUES , 2003 .

[7]  Eric Bakker,et al.  Beyond potentiometry: robust electrochemical ion sensor concepts in view of remote chemical sensing. , 2008, Talanta.

[8]  Ki Yong Ann,et al.  Chloride threshold level for corrosion of steel in concrete , 2007 .

[9]  U. Angst,et al.  Diffusion potentials as source of error in electrochemical measurements in concrete , 2009 .

[10]  Wouter Olthuis,et al.  Integrated coulometric sensor-actuator devices , 1995 .

[11]  J. D. Scantlebury,et al.  Monitoring chloride concentrations in hardened cement pastes using ion selective electrodes , 1996 .

[12]  Ian F. C. Smith,et al.  A new system for early chloride detection in concrete , 2008 .

[13]  Pd Cady,et al.  Predicting Service Life of Concrete Bridge Decks Subject to Reinforcement Corrosion , 1992 .

[14]  Rong-Gui Du,et al.  In situ measurement of Cl- concentrations and pH at the reinforcing steel/concrete interface by combination sensors. , 2006, Analytical chemistry.

[15]  J. Eijkel,et al.  Detection of protein concentrations with chronopotentiometry , 1997 .

[16]  Miguel Ángel Climent-Llorca,et al.  Embeddable Ag/AgCl sensors for in-situ monitoring chloride contents in concrete , 1996 .

[17]  Ueli M. Angst,et al.  Potentiometric determination of the chloride ion activity in cement based materials , 2010 .

[18]  Yoshio Umezawa,et al.  CRC Handbook of Ion Selective Electrodes: Selectivity Coefficients , 1990 .

[19]  Velu Saraswathy,et al.  Electrochemical studies on the performance characteristics of alkaline solid embeddable sensor for concrete environments , 2008 .

[20]  Vladimir S. Ban,et al.  Determination of chloride ion concentration in concrete by means of near infra-red spectroscopy , 2011, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[21]  P. Makedonski Synthesis of new optical sensors for determination of pH and chloride ions in reinforced concrete , 2004 .