Two-Dimensional Tracking of Heart Wall for Detailed Analysis of Heart Function at High Temporal and Spatial Resolutions

For noninvasive and quantitative measurements of global two-dimensional (2D) heart wall motion, speckle tracking methods have been developed and applied. These methods overcome the limitation of tissue Doppler imaging (TDI), which is susceptible to aliasing, by directly tracking backscattered echoes by pattern matching techniques, i.e., the cross-correlation or the sum of absolute differences, in real time. In these conventional methods, the frame rate (FR) is limited to about 200 Hz, corresponding to the sampling period of 5 ms. However, myocardial function during the isovolumic contraction period obtained by these conventional speckle tracking methods remains unclear owing to low temporal and spatial resolutions of these methods. Moreover, the accuracy of the speckle tracking method depends on an important parameter, i.e., the size of the correlation kernel. To track backscattered echoes accurately, it is necessary to determine the optimal kernel size. However, the optimal kernel size has not been thoroughly investigated. In this study, correlation kernel size, which determines the tracking accurately, was optimized by evaluating root mean squared (RMS) errors in the lateral and axial displacements of a phantom estimated by speckle tracking methods at high spatial and temporal resolutions. For this purpose, the RF data from the longitudinal-axis cross-sectional view for the interventricular septum (IVS) were acquired on the basis of parallel beam forming (PBF) to improve temporal and spatial resolutions. A wide transmit beam scanned in 7 different directions sparsely and 16 receiving beams were generated for each transmission. The RF data of the phantom and the heart wall were obtained at high spatial (angle intervals of scan lines: 0.375 degrees) and temporal [frame rate (FR): 1020 Hz] resolutions. The determined optimal size of the correlation kernel was 7.9° ×4.8 mm. Estimated displacements of the phantom were in good agreement with the actual displacement at an RMS error of 0.34 mm. Furthermore, the IVS motion during the isovolumic contraction (IC) was analyzed in detail. The speckle tracking method using the optimal kernel size 7.9° ×4.8 mm was applied to multiple points in IVS to estimate 2D displacements during the IC period. In this period, a rapid displacement of IVS at a small amplitude of 1.5 mm, which suggests the expansion of the left ventricle and has not been measured by conventional tracking methods at a low temporal resolution, was detected by 2D tracking. Furthermore, the displacement on the apical side was found to be delayed by 10 ms compared with that on the basal side. These results indicate the potential of this method in the high-accuracy estimation of 2D displacements and detailed analyses of physiological function of the myocardium.

[1]  P. Suetens,et al.  Comparison of time-domain displacement estimators for two-dimensional RF tracking. , 2003, Ultrasound in medicine & biology.

[2]  M E Anderson,et al.  Speckle tracking for multi-dimensional flow estimation. , 2000, Ultrasonics.

[3]  G R Sutherland,et al.  Doppler tissue imaging: myocardial wall motion velocities in normal subjects. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[4]  P. Suetens,et al.  RF-based two-dimensional cardiac strain estimation: a validation study in a tissue-mimicking phantom , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[6]  G R Sutherland,et al.  Color Doppler myocardial imaging: a new technique for the assessment of myocardial function. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  Dan Adam,et al.  Assessment of myocardial regional strain and strain rate by tissue tracking in B-mode echocardiograms. , 2006, Ultrasound in medicine & biology.

[8]  Motion-Compensated Frame-Accumulating Method to Improve Quality of Carotid Artery Images , 2007 .

[9]  H. Kanai,et al.  Propagation of spontaneously actuated pulsive vibration in human heart wall and in vivo viscoelasticity estimation , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  W. Walker,et al.  A comparison of the performance of time-delay estimators in medical ultrasound , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  H Kanai,et al.  Myocardial rapid velocity distribution. , 2001, Ultrasound in medicine & biology.

[12]  Hiroshi Kanai,et al.  Ultrasonic Imaging of Propagation of Contraction and Relaxation in the Heart Walls at High Temporal Resolution , 2007 .

[13]  Hiroshi Kanai,et al.  Basic Study on Detection of Outer Boundary of Arterial Wall Using Its Longitudinal Motion , 2007 .

[14]  E. Konofagou,et al.  A composite high-frame-rate system for clinical cardiovascular imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  J. Ophir,et al.  Methods for Estimation of Subsample Time Delays of Digitized Echo Signals , 1995 .

[16]  W A Mandarino,et al.  Color-coded measures of myocardial velocity throughout the cardiac cycle by tissue Doppler imaging to quantify regional left ventricular function. , 1996, American heart journal.

[17]  R. F. Wagner,et al.  Properties of Acoustical Speckle in the Presence of Phase Aberration Part II: Correlation Lengths , 1988, Ultrasonic imaging.

[18]  M. Yamagishi,et al.  New method for evaluating left ventricular wall motion by color-coded tissue Doppler imaging: in vitro and in vivo studies. , 1995, Journal of the American College of Cardiology.

[19]  H. Hasegawa,et al.  Simultaneous imaging of artery-wall strain and blood flow by high frame rate acquisition of RF signals , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[21]  Gregg E. Trahey,et al.  Properties of Acoustical Speckle in the Presence of Phase Aberration Part I: First Order Statistics , 1988, Ultrasonic imaging.

[22]  H. Kanai Propagation of vibration caused by electrical excitation in the normal human heart. , 2009, Ultrasound in medicine & biology.

[23]  G. Trahey,et al.  Angle Independent Ultrasonic Detection of Blood Flow , 1987, IEEE Transactions on Biomedical Engineering.

[25]  Hiroshi Kanai,et al.  Automated Segmentation of Heart Wall Using Coherence Among Ultrasonic RF Echoes , 2008 .

[26]  A. Støylen,et al.  Real-time strain rate imaging of the left ventricle by ultrasound. , 1998, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[27]  In Vivo Measurement of Small Velocity Signals and Change in Thickness of the Heart Walls , 1999 .

[28]  G E Trahey,et al.  A real time system for quantifying and displaying two-dimensional velocities using ultrasound. , 1993, Ultrasound in medicine & biology.