Stability constrained optimal power flow for the balancing market using genetic algorithms

Angle stability (both transient and oscillatory) is an important constraint in power system operation. The work presented in this paper describes a genetic algorithm (GA) based approach for solving the problem of angle stability constrained optimal power flow. The control parameter modeled in the chromosome of the GA is generation power of the units. The application presented here is the UK balancing market using balancing mechanism units (BMUs). The BMUs put into the GA list depend on either their bid/offer price or their impact of generation change on system stability. Sensitivity factors, obtained by doing perturbations, are used to represent a BMU's impact on system stability. A novel mapping method is employed to maintain power balance. Stability constraints are dealt with as penalty cost, and their contribution to the fitness of the objective function is evaluated independently, so that the search for the optimal solution concentrates on feasible solutions. Tests on a reduced UK system show that the proposed GA is able to cope with the highly nonlinear optimization problem. Numerical simulation results of the test system are presented.

[1]  A. David,et al.  Security-based rescheduling of transactions in a deregulated power system , 1999 .

[2]  Ka Wing Chan,et al.  Transient and dynamic stability constraint assessment using hybrid TEF and clustering analysis , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[3]  A. Y. Chang,et al.  Enhanced "Second Kick" methods for on-line dynamic security assessment , 1996 .

[4]  James A. Momoh,et al.  Challenges to optimal power flow , 1997 .

[5]  R. Adapa,et al.  A review of selected optimal power flow literature to 1993. II. Newton, linear programming and interior point methods , 1999 .

[6]  K. Menninger Law , 1984, Encyclopedia of Autism Spectrum Disorders.

[7]  T. S. Chung,et al.  Transient stability limit conditions analysis using a corrected transient energy function approach , 2000 .

[8]  A. Li,et al.  Development of constrained-genetic-algorithm load-flow method , 1997 .

[9]  A. A. Fouad,et al.  Stability constrained optimal rescheduling of generation , 1993 .

[10]  M. E. Bradley,et al.  Optimal constraint management for system operations under neta , 2002 .

[11]  R. Adapa,et al.  A review of selected optimal power flow literature to 1993. I. Nonlinear and quadratic programming approaches , 1999 .

[12]  Kwok W. Cheung,et al.  BC Hydro's on-line transient stability assessment (TSA) model development, analysis and post-processing , 1995 .

[13]  Deqiang Gan,et al.  Stability-constrained optimal power flow , 2000 .

[14]  A. K. David,et al.  Dispatch methodologies for open access transmission systems , 1998 .

[15]  Vassilios Petridis,et al.  Optimal power flow by enhanced genetic algorithm , 2002 .