Comparison of the Airway Scope®, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study

We compared the Airway Scope® with a gum elastic bougie and fibreoptic bronchoscope in a manikin with a simulated Cormack and Lehane Grade 3 laryngoscopic view. Twenty‐seven anaesthetists intubated the trachea of the manikin with these devices and the time required for intubation was measured. They were then asked to rate the subjective difficulty of intubation (1 = very easy; 5 = very difficult). Mean (SD) intubation times were 16.6 (11.2) s with the Airway Scope, 29.4 (10.9) s with the gum elastic bougie (p < 0.0001), and 30.6 (20.0) s with the fibreoptic bronchoscope (p < 0.0001). The median (range) difficulty was 2 (1–4) with the Airway Scope, 3 (2–4) with the gum elastic bougie (p < 0.001), and 2 (1–5) with the fibreoptic bronchoscope (p = 0.014). In Cormack and Lehane grade 3 laryngoscopic views, the Airway Scope may enable faster and easier tracheal intubation than does a Macintosh laryngoscope with a gum elastic bougie or a fibreoptic bronchoscope.

[1]  S. T. Tan,et al.  Evaluation of the new Viewmax laryngoscope in a simulated difficult airway , 2006, Acta anaesthesiologica Scandinavica.

[2]  J. R. Young,et al.  Difficult tracheal intubation: a retrospective study , 1987, Anaesthesia.

[3]  T. Kikuchi,et al.  The Airway Scope for difficult intubation. , 2007, Journal of clinical anesthesia.

[4]  H. Thode,et al.  Bullard laryngoscopy by naïve operators in the cervical spine immobilized patient. , 2005, Journal of Emergency Medicine.

[5]  K L Posner,et al.  Adverse respiratory events in anesthesia: a closed claims analysis. , 1990, Anesthesiology.

[6]  S. Morris,et al.  A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study , 2006, Anaesthesia.

[7]  S. Yentis Predicting difficult intubation – worthwhile exercise or pointless ritual? , 2002, Anaesthesia.

[8]  R. Hesselfeldt,et al.  Evaluation of the airway of the SimMan™ full‐scale patient simulator , 2005, Acta anaesthesiologica Scandinavica.

[9]  M. Weiss,et al.  difficult airway management: comparison of the bullard laryngoscope with the video-optical intubation stylet , 2000, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[10]  K. Hongo,et al.  Description and first clinical application of AirWay Scope for tracheal intubation. , 2006, Journal of neurosurgical anesthesiology.

[11]  E. Crosby,et al.  The unanticipated difficult airway with recommendations for management , 1998, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[12]  R S Cormack,et al.  Difficult tracheal intubation in obstetrics , 1983, Anaesthesia.

[13]  M. Ozaki,et al.  Intubating laryngeal mask airway allows tracheal intubation when the cervical spine is immobilized by a rigid collar. , 2004, British journal of anaesthesia.