First human case of retrograde transcatheter implantation of an aortic valve prosthesis.

The transcatheter route is an emerging approach to treating valvular disease in high-risk patients. The 1st clinical antegrade transcatheter placement of an aortic valve prosthesis was reported in 2002. We describe the first retrograde transcatheter implantation of a new aortic valve prosthesis, in a 62-year-old man with inoperable calcific aortic stenosis and multiple severe comorbidities. Via the right femoral artery, a Cook introducer was advanced into the abdominal aorta. The aortic valve was crossed with a straight wire, and a pigtail catheter was advanced into the left ventricle to obtain pressure-gradient and anatomic measurements. An 18-mm valvuloplasty balloon was then used to predilate the aortic valve. Initial attempts to position the prosthetic valve caused a transient cardiac arrest. Implantation was achieved by superimposing the right coronary angiogram onto fluoroscopic landmarks in the same radiographic plane. A balloon-expandable frame was used to deliver the valve. After device implantation, the transvalvular gradient was <5 mmHg. The cardiac output increased from 1 to 5 L/min, and urine production increased to 200 mL/h. The patient was extubated on the 2nd postimplant day. Twelve hours later, he had to be reintubated because of respiratory distress and high pulmonary pressures. His condition deteriorated, and he died of biventricular failure and refractory hypotension on day 5. Despite the severe hypotension, valve function was satisfactory on echo-Doppler evaluation. In our patient, retrograde transcatheter implantation of a prosthetic aortic valve yielded excellent hemodynamic results and paved the way for further use of this technique in selected high-risk patients.

[1]  F. Beyersdorf,et al.  Percutaneous aortic valve replacement: an experimental study. I. Studies on implantation. , 2002, The Journal of thoracic and cardiovascular surgery.

[2]  Younes Boudjemline,et al.  Steps Toward Percutaneous Aortic Valve Replacement , 2002, Circulation.

[3]  R GORLIN,et al.  Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. , 1951, American heart journal.

[4]  P. Bonhoeffer,et al.  Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction , 2000, The Lancet.

[5]  J. Sochman,et al.  Percutaneous Transcatheter Aortic Disc Valve Prosthesis Implantation: A Feasibility Study , 2000, CardioVascular and Interventional Radiology.

[6]  H. Davies CATHETER-MOUNTED VALVE FOR TEMPORARY RELIEF OF AORTIC INSUFFICIENCY , 1965 .

[7]  L. Anthopoulos,et al.  Catheter-mounted aortic valves. , 1971, The Annals of thoracic surgery.

[8]  David Paniagua,et al.  Images in cardiovascular medicine. Percutaneous heart valve in the chronic in vitro testing model. , 2002, Circulation.

[9]  M. Leon,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis First Human Case Description , 2002 .

[10]  P. Cascade,et al.  A temporary catheter-tip aortic valve: hemodynamic effects on experimental acute aortic insufficiency. , 1976, The Annals of thoracic surgery.

[11]  L. Knudsen,et al.  Catheter-Implanted Prosthetic Heart Valves , 1993, The International journal of artificial organs.

[12]  J Kachaner,et al.  Transcatheter implantation of a bovine valve in pulmonary position: a lamb study. , 2000, Circulation.

[13]  J M Hasenkam,et al.  Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs. , 1992, European heart journal.

[14]  Younes Boudjemline,et al.  Percutaneous insertion of the pulmonary valve. , 2002, Journal of the American College of Cardiology.

[15]  T. Matsubara,et al.  Balloon catheter with check valves for experimental relief of acute aortic regurgitation. , 1992, American heart journal.

[16]  S. Wallace,et al.  Development and initial experimental evaluation of a prosthetic aortic valve for transcatheter placement. Work in progress. , 1992, Radiology.