Development of a micro-computed tomography-based image-guided conformal radiotherapy system for small animals.

PURPOSE To report on the physical aspects of a system in which radiotherapy functionality was added to a micro-computed tomography (microCT) scanner, to evaluate the accuracy of this instrument, and to and demonstrate the application of this technology for irradiating tumors growing within the lungs of mice. METHODS AND MATERIALS A GE eXplore RS120 microCT scanner was modified by the addition of a two-dimensional subject translation stage and a variable aperture collimator. Quality assurance protocols for these devices, including measurement of translation stage positioning accuracy, collimator aperture accuracy, and collimator alignment with the X-ray beam, were devised. Use of this system for image-guided radiotherapy was assessed by irradiation of a solid water phantom as well as of two mice bearing spontaneous MYC-induced lung tumors. Radiation damage was assessed ex vivo by immunohistochemical detection of gammaH2AX foci. RESULTS The positioning error of the translation stage was found to be <0.05 mm, whereas after alignment of the collimator with the X-ray axis through adjustment of its displacement and rotation, the collimator aperture error was <0.1 mm measured at isocenter. Computed tomography image-guided treatment of a solid water phantom demonstrated target localization accuracy to within 0.1 mm. Gamma-H2AX foci were detected within irradiated lung tumors in mice, with contralateral lung tissue displaying background staining. CONCLUSIONS Addition of radiotherapy functionality to a microCT scanner is an effective means of introducing image-guided radiation treatments into the preclinical setting. This approach has been shown to facilitate small-animal conformal radiotherapy while leveraging existing technology.

[1]  Dean W. Felsher,et al.  Combined Inactivation of MYC and K-Ras Oncogenes Reverses Tumorigenesis in Lung Adenocarcinomas and Lymphomas , 2008, PloS one.

[2]  S Mutic,et al.  MicroRT-small animal conformal irradiator. , 2007, Medical physics.

[3]  Paul J Keall,et al.  A bone composition model for Monte Carlo x-ray transport simulations. , 2009, Medical physics.

[4]  B E Bjärngard,et al.  Beam alignment tests for therapy accelerators. , 1981, International journal of radiation oncology, biology, physics.

[5]  Billy W. Loo,et al.  RT_Image: An Open-Source Tool for Investigating PET in Radiation Oncology , 2007, Technology in cancer research & treatment.

[6]  J. Van Dyk,et al.  Partial volume rat lung irradiation: an evaluation of early DNA damage. , 1998, International journal of radiation oncology, biology, physics.

[7]  I. Yeung,et al.  Partial volume rat lung irradiation; assessment of early DNA damage in different lung regions and effect of radical scavengers. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  Christopher H Contag,et al.  Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner. , 2007, Medical physics.

[9]  F. Sarkar,et al.  Progression of renal cell carcinoma is inhibited by genistein and radiation in an orthotopic model , 2007, BMC Cancer.

[10]  Peter Kazanzides,et al.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities. , 2008, International journal of radiation oncology, biology, physics.

[11]  Paul Keall,et al.  Commissioning of a novel microCT/RT system for small animal conformal radiotherapy , 2009, Physics in medicine and biology.

[12]  B. Wessels,et al.  Overview of animal studies comparing radioimmunotherapy with dose equivalent external beam irradiation. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  David A. Jaffray,et al.  SU‐GG‐J‐70: Development of An Image‐Guided Conformal Small Animal Irradiation Platform , 2008 .

[14]  J. Boone,et al.  Small-animal X-ray dose from micro-CT. , 2004, Molecular imaging.

[15]  E. Rogakou,et al.  DNA Double-stranded Breaks Induce Histone H2AX Phosphorylation on Serine 139* , 1998, The Journal of Biological Chemistry.

[16]  D. Grignon,et al.  Neutron or photon irradiation for prostate tumors: enhancement of cytokine therapy in a metastatic tumor model. , 2001, Clinical cancer research : an official journal of the American Association for Cancer Research.