Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system—A case‐crossover pilot study

The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral test battery were compared in four 1‐hr sessions with and without exposure to magnetic fields, and with and without additional movements. Adverse effects were found for hand coordination (–4%, P < 0.05; Pursuit Aiming II) and near visual contrast sensitivity (–16% and –15%, P < 0.10; Vistech 6000™). The results from the remaining tests were inconclusive due to a strong learning effect. No additional effect from gradient fields was detected. The results indicate that working near a 1.5 Tesla MRI system may lead to neurobehavioral effects. Further research is recommended, especially in members of operating teams using interactive MRI systems. Magn Reson Med 50:670–674, 2003. © 2003 Wiley‐Liss, Inc.

[1]  J. Schenck Safety of Strong, Static Magnetic Fields , 2000, Journal of magnetic resonance imaging : JMRI.

[2]  C L Dumoulin,et al.  Human exposure to 4.0-Tesla magnetic fields in a whole-body scanner. , 1992, Medical physics.

[3]  F. Prato,et al.  Behavioral effects of exposure to nuclear magnetic resonance imaging: II. Spatial memory tests. , 1986, Magnetic resonance imaging.

[4]  Assessment of the Vistech contrast sensitivity test for repeated-measures applications. , 1990 .

[5]  F. Smith,et al.  Cognitive evaluation following NMR imaging of the brain. , 1984, Journal of neurology, neurosurgery, and psychiatry.

[6]  S. R. Searle,et al.  Generalized, Linear, and Mixed Models , 2005 .

[7]  D Ghosh,et al.  Statistical methods for analyzing repeated measures. , 1999, Journal of pharmacological and toxicological methods.

[8]  P. Fatouros,et al.  Exposure to magnetic resonance imaging does not produce taste aversion in rats , 1987, Physiology & Behavior.

[9]  David Saloner,et al.  Application of MR technology to endovascular interventions in an XMR Suite , 2002 .

[10]  G. Sutherland,et al.  Advances in mobile intraoperative magnetic resonance imaging. , 2000, Neurosurgery.

[11]  James C. Smith,et al.  Behavioral Effects of High-Strength Static Magnetic Fields on Rats , 2003, The Journal of Neuroscience.

[12]  Static magnetic field and the inner ear. A functional study of hearing and vestibular function in man after exposure to a static magnetic field. , 1999, Scandinavian audiology.

[13]  M. Maclure The case-crossover design: a method for studying transient effects on the risk of acute events. , 1991, American journal of epidemiology.

[14]  本田 純久 Longitudinal Data , 2003, Encyclopedia of Wireless Networks.

[15]  A. Kangarlu,et al.  Cognitive, cardiac, and physiological safety studies in ultra high field magnetic resonance imaging. , 1999, Magnetic resonance imaging.

[16]  F. Prato,et al.  Behavioral effects of exposure to nuclear magnetic resonance imaging: I. Open-field behavior and passive avoidance learning in rats. , 1986, Magnetic resonance imaging.

[17]  O. J. Sizemore,et al.  Lessons learned--15 years of the WHO-NCTB: a review. , 2000, Neurotoxicology.

[18]  Assessment of the Vistech Contrast Sensitivity Test for Repeated‐Measures Applications , 1990, Optometry and vision science : official publication of the American Academy of Optometry.

[19]  R W Günther,et al.  Catheter visualization using locally induced, actively controlled field inhomogeneities , 1997, Magnetic resonance in medicine.

[20]  M. L. Wood,et al.  Magnetic Resonance Procedures: Health Effects and Safety , 2001 .

[21]  P A Oberg,et al.  Influence on vision of extremely low frequence electromagnetic fields. Industrial measurements, magnetophosphene studies volunteers and intraretinal studies in animals. , 1979, Acta ophthalmologica.