Electrical characteristic of the titanium mesh electrode for transcutaneous intrabody communication to monitor implantable artificial organs

We have developed a tissue-inducing electrode using titanium mesh to obtain mechanically and electrically stable contact with the tissue for a new transcutaneous communication system using the human body as a conductive medium. In this study, we investigated the electrical properties of the titanium mesh electrode by measuring electrode–tissue interface resistance in vivo. The titanium mesh electrode (Hi-Lex Co., Zellez, Hyogo, Japan) consisted of titanium fibers (diameter of 50 μm), and it has an average pore size of 200 μm and 87 % porosity. The titanium mesh electrode has a diameter of 5 mm and thickness of 1.5 mm. Three titanium mesh electrodes were implanted separately into the dorsal region of the rat. We measured the electrode–electrode impedance using an LCR meter for 12 weeks, and we calculated the tissue resistivity and electrode–tissue interface resistance. The electrode–tissue interface resistance of the titanium mesh electrode decreased slightly until the third POD and then continuously increased to 75 Ω. The electrode–tissue interface resistance of the titanium mesh electrode is stable and it has lower electrode–tissue interface resistance than that of a titanium disk electrode. The extracted titanium mesh electrode after 12 weeks implantation was fixed in 10 % buffered formalin solution and stained with hematoxylin-eosin. Light microscopic observation showed that the titanium mesh electrode was filled with connective tissue, inflammatory cells and fibroblasts with some capillaries in the pores of the titanium mesh. The results indicate that the titanium mesh electrode is a promising electrode for the new transcutaneous communication system.

[1]  Eiji Okamoto,et al.  Evaluation of titanium mesh electrode using for transcutaneous intrabody communication by tissue-electrode impedance , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[2]  J. Jansen,et al.  A One Stage Versus Two Stage Surgical Technique: Tissue Reaction to a Percutaneous Device Provided With Titanium Fiber Mesh Applicable for Peritoneal Dialysis , 1996, ASAIO journal (1992).

[3]  K. Foster,et al.  RF-field interactions with biological systems: Electrical properties and biophysical mechanisms , 1980, Proceedings of the IEEE.

[4]  Eiji Okamoto,et al.  Measurement of electrode-tissue interface impedance for improvement of a transcutaneous data transmission using human body as transmission medium. , 2014, Bio-medical materials and engineering.

[5]  Tomoyuki Yambe,et al.  Transcutaneous communication system using the human body as conductive medium: influence of transmission data current on the heart. , 2013, Bio-medical materials and engineering.

[6]  Eiji Okamoto,et al.  Basic study of a transcutaneous information transmission system using intra-body communication , 2010, Journal of Artificial Organs.

[7]  John A Jansen,et al.  Bone formation by rat bone marrow cells cultured on titanium fiber mesh: effect of in vitro culture time. , 2002, Journal of biomedical materials research.

[8]  Tomoyuki Yambe,et al.  A new transcutaneous bidirectional communication for monitoring implanted artificial heart using the human body as a conductive medium. , 2012, Artificial organs.

[9]  J. Jansen,et al.  Wound healing phenomena in titanium fibre mesh: the influence of the length of implantation. , 1997, Biomaterials.

[10]  V Parsonnet,et al.  Comparison of Titanium‐Mesh and Porous Disc Electrodes for Epicardial Defibrillation , 1991, Pacing and clinical electrophysiology : PACE.

[11]  J. Jansen,et al.  A New Titanium Fiber Mesh-Cuffed Peritoneal Dialysis Catheter: Evaluation and Comparison with a Dacron-Cuffed Tenckhoff Catheter in Goats , 2001, Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis.

[12]  Y. Tabata,et al.  Bone regeneration using titanium nonwoven fabrics combined with fgf-2 release from gelatin hydrogel microspheres in rabbit skull defects. , 2008, Tissue engineering. Part A.

[13]  T. Nishinaka,et al.  Neointima-inducing inflow cannula with titanium mesh for left ventricular assist device , 2011, Journal of Artificial Organs.