The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.

To assess the performance of femoral orthopedic implants, they are often attached to cadaveric femurs, and biomechanical testing is performed. To identify areas of high stress, stress shielding, and to facilitate implant redesign, these tests are often accompanied by finite element (FE) models of the bone/implant system. However, cadaveric bone suffers from wide specimen to specimen variability both in terms of bone geometry and mechanical properties, making it virtually impossible for experimental results to be reproduced. An alternative approach is to utilize synthetic femurs of standardized geometry, having material behavior approximating that of human bone, but with very small specimen to specimen variability. This approach allows for repeatable experimental results and a standard geometry for use in accompanying FE models. While the synthetic bones appear to be of appropriate geometry to simulate bone mechanical behavior, it has not, however, been established what bone quality they most resemble, i.e., osteoporotic or osteopenic versus healthy bone. Furthermore, it is also of interest to determine whether FE models of synthetic bones, with appropriate adjustments in input material properties or geometric size, could be used to simulate the mechanical behavior of a wider range of bone quality and size. To shed light on these questions, the axial and torsional stiffness of cadaveric femurs were compared to those measured on synthetic femurs. A FE model, previously validated by the authors to represent the geometry of a synthetic femur, was then used with a range of input material properties and change in geometric size, to establish whether cadaveric results could be simulated. Axial and torsional stiffnesses and rigidities were measured for 25 human cadaveric femurs (simulating poor bone stock) and three synthetic "third generation composite" femurs (3GCF) (simulating normal healthy bone stock) in the midstance orientation. The measured results were compared, under identical loading conditions, to those predicted by a previously validated three-dimensional finite element model of the 3GCF at a variety of Young's modulus values. A smaller FE model of the 3GCF was also created to examine the effects of a simple change in bone size. The 3GCF was found to be significantly stiffer (2.3 times in torsional loading, 1.7 times in axial loading) than the presently utilized cadaveric samples. Nevertheless, the FE model was able to successfully simulate both the behavior of the 3GCF, and a wide range of cadaveric bone data scatter by an appropriate adjustment of Young's modulus or geometric size. The synthetic femur had a significantly higher stiffness than the cadaveric bone samples. The finite element model provided a good estimate of upper and lower bounds for the axial and torsional stiffness of human femurs because it was effective at reproducing the geometric properties of a femur. Cadaveric bone experiments can be used to calibrate FE models' input material properties so that bones of varying quality can be simulated.

[1]  W C Hayes,et al.  Age-related differences in post-yield damage in human cortical bone. Experiment and model. , 1996, Journal of biomechanics.

[2]  M Martens,et al.  The mechanical characteristics of the long bones of the lower extremity in torsional loading. , 1980, Journal of biomechanics.

[3]  W. Hayes,et al.  Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[4]  F. Kummer,et al.  Distal femoral fixation: A laboratory comparison of the 95° plate, antegrade and retrograde inserted reamed intramedullary nails , 1996 .

[5]  R. Huiskes,et al.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. , 1995, Journal of biomechanics.

[6]  T D Brown,et al.  Structural properties of a new design of composite replicate femurs and tibias. , 2001, Journal of biomechanics.

[7]  A. Yettram,et al.  Stress and strain distribution within the intact femur: compression or bending? , 1996, Medical engineering & physics.

[8]  F. Kummer,et al.  Fixation of Periprosthetic Femoral Shaft Fractures: A Biomechanical Comparison of Two Techniques , 2001, Journal of orthopaedic trauma.

[9]  S. S. Stevens,et al.  A Biomechanical Study of Three Wiring Techniques for Cerclage‐Plating , 1995, Journal of orthopaedic trauma.

[10]  L. S. Matthews,et al.  Stable fixation of intertrochanteric fractures. , 1974, The Journal of bone and joint surgery. American volume.

[11]  L Cristofolini,et al.  A comparative study on different methods of automatic mesh generation of human femurs. , 1998, Medical engineering & physics.

[12]  E Y Chao,et al.  Normal axial alignment of the lower extremity and load-bearing distribution at the knee. , 1990, Clinical orthopaedics and related research.

[13]  E. Radin,et al.  Mechanical and morphological effects of strain rate on fatigue of compact bone. , 1989, Bone.

[14]  A. Cappello,et al.  Mechanical validation of whole bone composite tibia models. , 2000, Journal of biomechanics.

[15]  A L Yettram,et al.  Finite element analysis of a Gamma nail within a fractured femur. , 1998, Medical engineering & physics.

[16]  J G Clement,et al.  Age‐related changes in cortical porosity of the midshaft of the human femur , 1997, Journal of anatomy.

[17]  G. L. Lucas,et al.  Construct stiffness of different fixation methods for supracondylar femoral fractures above total knee prostheses. , 2000, American journal of orthopedics.

[18]  W. Brekelmans,et al.  A new method to analyse the mechanical behaviour of skeletal parts. , 1972, Acta orthopaedica Scandinavica.

[19]  J. K. Spelt,et al.  Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading. , 2004, Medical engineering & physics.

[20]  R. Martin,et al.  Determinants of the mechanical properties of bones. , 1991, Journal of biomechanics.

[21]  W. Hayes,et al.  Sex differences in age‐related remodeling of the femur and tibia , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[22]  M. Bosse,et al.  Unstable Proximal Extraarticular Tibia Fractures: A Biomechanical Evaluation of Four Methods of Fixation , 2004, Journal of orthopaedic trauma.

[23]  J. P. Paul Approaches to design - Force actions transmitted by joints in the human body , 1976, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[24]  W. Hayes,et al.  STRESS ANALYSIS OF A SIMPLIFIED COMPRESSION PLATE FIXATION SYSTEM FOR FRACTURED BONES††This work was supported by NIH RCDA AM00749 and by a research grant from Synthes, Ltd. , 1983 .

[25]  F. Kummer,et al.  Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. , 2000, The Journal of arthroplasty.

[26]  R Huiskes,et al.  On the modelling of long bones in structural analyses. , 1982, Journal of biomechanics.

[27]  B P McNamara,et al.  Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction. , 1997, Journal of biomechanics.

[28]  J. Kellam,et al.  Comparative biomechanical analysis of supracondylar femur fracture fixation: locked intramedullary nail versus 95-degree angled plate. , 1997, Journal of orthopaedic trauma.

[29]  L Cristofolini,et al.  Mechanical validation of whole bone composite femur models. , 1996, Journal of biomechanics.

[30]  A L Yettram,et al.  Intramedullary femoral nails: one or two lag screws? A preliminary study. , 2000, Medical engineering & physics.

[31]  M Martens,et al.  Mechanical behaviour of femoral bones in bending loading. , 1986, Journal of biomechanics.

[32]  A. Tencer,et al.  Relationship of mechanical factors to the strength of proximal femur fractures fixed with cancellous screws. , 1996, Journal of orthopaedic trauma.

[33]  W. Hayes,et al.  Stress analysis of compression plate fixation and its effects on long bone remodeling. , 1985, Journal of biomechanics.

[34]  J. Cordey,et al.  Loading model for the human femur taking the tension band effect of the ilio-tibial tract into account. , 1999, Injury.

[35]  G. Smidt,et al.  Measurement of hip joint motion during walking , 1969 .

[36]  R. D. Wood,et al.  Three dimensional stress analysis of the human femur. , 1977, Computers in biology and medicine.

[37]  C. Ruff,et al.  Age-related changes in female femoral neck geometry: Implications for bone strength , 1993, Calcified Tissue International.

[38]  J. Currey The effect of porosity and mineral content on the Young's modulus of elasticity of compact bone. , 1988, Journal of biomechanics.

[39]  W C Hayes,et al.  Three-dimensional finite element analysis of a simplified compression plate fixation system. , 1984, Journal of biomechanical engineering.

[40]  B. Mather Variation with age and sex in strength of the femur , 2006, Medical and biological engineering.

[41]  A. Tencer,et al.  A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[42]  G. Smidt,et al.  Measurement of hip-joint motion during walking. Evaluation of an electrogoniometric method. , 1969, The Journal of bone and joint surgery. American volume.