A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI

Combined EEG/fMRI recording has been used to localize the generators of EEG events and to identify subject state in cognitive studies and is of increasing interest. However, the large EEG artifacts induced during fMRI have precluded simultaneous EEG and fMRI recording, restricting study design. Removing this artifact is difficult, as it normally exceeds EEG significantly and contains components in the EEG frequency range. We have developed a recording system and an artifact reduction method that reduce this artifact effectively. The recording system has large dynamic range to capture both low-amplitude EEG and large imaging artifact without distortion (resolution 2 microV, range 33.3 mV), 5-kHz sampling, and low-pass filtering prior to the main gain stage. Imaging artifact is reduced by subtracting an averaged artifact waveform, followed by adaptive noise cancellation to reduce any residual artifact. This method was validated in recordings from five subjects using periodic and continuous fMRI sequences. Spectral analysis revealed differences of only 10 to 18% between EEG recorded in the scanner without fMRI and the corrected EEG. Ninety-nine percent of spike waves (median 74 microV) added to the recordings were identified in the corrected EEG compared to 12% in the uncorrected EEG. The median noise after artifact reduction was 8 microV. All these measures indicate that most of the artifact was removed, with minimal EEG distortion. Using this recording system and artifact reduction method, we have demonstrated that simultaneous EEG/fMRI studies are for the first time possible, extending the scope of EEG/fMRI studies considerably.

[1]  J. R. Baker,et al.  Simultaneous functional magnetic resonance imaging and electrophysiological recording , 1995 .

[2]  J Sijbers,et al.  Restoration of MR-induced artifacts in simultaneously recorded MR/EEG data. , 1999, Magnetic resonance imaging.

[3]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.

[4]  T Landis,et al.  Non-invasive epileptic focus localization using EEG-triggered functional MRI and electromagnetic tomography. , 1998, Electroencephalography and clinical neurophysiology.

[5]  K. Chiappa,et al.  EEG during MR imaging , 1995, Neurology.

[6]  R. Kreis,et al.  Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences , 1999, Magnetic resonance in medicine.

[7]  Ernst Fernando Lopes Da Silva Niedermeyer,et al.  Electroencephalography, basic principles, clinical applications, and related fields , 1982 .

[8]  Karl J. Friston,et al.  Event‐related f MRI , 1997, Human brain mapping.

[9]  L. Lemieux,et al.  Recording of EEG during fMRI experiments: Patient safety , 1997, Magnetic resonance in medicine.

[10]  R. Frayne,et al.  Minimizing interference from magnetic resonance imagers during electrocardiography , 1998, IEEE Transactions on Biomedical Engineering.

[11]  Robert Turner,et al.  An Adaptive MRI Gradient Noise Filter , 1998, NeuroImage.

[12]  Karl J. Friston,et al.  Event-related fMRI , 1997 .

[13]  J R Ives,et al.  EEG-triggered echo-planar functional MRI in epilepsy , 1996, Neurology.

[14]  M R Symms,et al.  EEG-triggered functional MRI of interictal epileptiform activity in patients with partial seizures. , 1999, Brain : a journal of neurology.

[15]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[16]  Oliver Josephs,et al.  Processing auditory stimuli across the sleep-wake cycle: A functional MRI study in humans , 2000 .