Enhanced 4D cone-beam CT with inter-phase motion model.

Four-dimensional (4D) cone-beam CT (CBCT) is commonly obtained by respiratory phase binning of the projections, followed by independent reconstructions of the rebinned data in each phase bin. Due to the significantly reduced number of projections per reconstruction, the quality of the 4DCBCT images is often degraded by view-aliasing artifacts easily seen in the axial view. Acquisitions using multiple gantry rotations or slow gantry rotation can increase the number of projections and substantially improve the 4D images. However, the extra cost of the scan time may set fundamental limits to their applications in clinics. Improving the trade-off between image quality and scan time is the key to making 4D onboard imaging practical and more useful. In this article, we present a novel technique toward high-quality 4DCBCT imaging without prolonging the acquisition time, referred to as the "enhanced 4DCBCT". The method correlates the data in different phase bins and integrates the internal motion into the 4DCBCT image formulation. Several strategies of the motion derivation are discussed, and the resultant images are assessed with numerical simulations as well as a clinical case.

[1]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[2]  L Xing,et al.  Motion correction for improved target localization with on-board cone-beam computed tomography , 2006, Physics in medicine and biology.

[3]  P. Munro,et al.  Four-dimensional cone-beam computed tomography using an on-board imager. , 2006, Medical physics.

[4]  A. Boyer,et al.  Radiation dose reduction in four-dimensional computed tomography. , 2005, Medical physics.

[5]  Jeffrey A. Fessler,et al.  Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation. , 2005 .

[6]  Jorge Nocedal,et al.  On the limited memory BFGS method for large scale optimization , 1989, Math. Program..

[7]  T. Pan Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT. , 2005, Medical physics.

[8]  Mark Oldham,et al.  Cone-beam-CT guided radiation therapy: A model for on-line application. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  David A. Jaffray,et al.  Towards a One-Step Scan and Treat Process for Palliative Radiotherapy - a Potential Application for Cone Beam Computerized Tomography (CBCT) , 2005 .

[10]  David R. Haynor,et al.  PET-CT image registration in the chest using free-form deformations , 2003, IEEE Transactions on Medical Imaging.

[11]  Xiaochuan Pan,et al.  Partial volume and aliasing artefacts in helical cone-beam CT. , 2004, Physics in medicine and biology.

[12]  Patrick A Kupelian,et al.  Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. , 2005, Medical physics.

[13]  J. McClelland,et al.  A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. , 2006, Medical physics.

[14]  Gregory C Sharp,et al.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors. , 2004, Physics in medicine and biology.

[15]  Jeffrey A. Fessler,et al.  Estimating 3-D Respiratory Motion From Orbiting Views by Tomographic Image Registration , 2007, IEEE Transactions on Medical Imaging.

[16]  G H Olivera,et al.  The use of megavoltage CT (MVCT) images for dose recomputations , 2005, Physics in medicine and biology.

[17]  Xiaochuan Pan,et al.  Reconstruction of 3D Regions-of-Interest from Data in Reduced Helical Cone-beam Scans , 2005, Technology in cancer research & treatment.

[18]  L. Xing,et al.  Overview of image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[19]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[20]  M. V. van Herk,et al.  Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). , 2005, International journal of radiation oncology, biology, physics.

[21]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[22]  Ping Xia,et al.  Low-dose megavoltage cone-beam CT for radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[23]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[24]  He Wang,et al.  Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes. , 2005, International journal of radiation oncology, biology, physics.

[25]  Uwe Oelfke,et al.  Linac-integrated 4D cone beam CT: first experimental results , 2006, Physics in medicine and biology.

[26]  John Wong,et al.  Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. , 2004, International journal of radiation oncology, biology, physics.

[27]  Eduard Schreibmann,et al.  Mapping Electron Density Distribution from Planning CT to Cone-Beam CT (CBCT): a Novel Strategy for Accurate Dose Calculation Based on CBCT , 2005 .

[28]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[29]  L. Xing,et al.  Image interpolation in 4D CT using a BSpline deformable registration model. , 2006, International journal of radiation oncology, biology, physics.

[30]  M van Herk,et al.  Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans , 2005, Physics in medicine and biology.

[31]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[32]  Xiaochuan Pan,et al.  Image reconstruction in peripheral and central regions-of-interest and data redundancy. , 2005, Medical physics.

[33]  Torsten Rohlfing,et al.  Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint , 2003, IEEE Transactions on Medical Imaging.