Macular Thickness by Age and Gender in Healthy Eyes Using Spectral Domain Optical Coherence Tomography

Purpose To determine normal macular thickness and its variation by age and gender in healthy eyes using spectral-domain optical coherence tomography (SD-OCT). Methods In this cross-sectional analysis, two hundred and twenty eyes of 220 healthy subjects underwent raster scanning using Topcon SD-OCT system, at the Department of Ophthalmology, Dow University of Health Sciences and Civil Hospital Karachi, Pakistan. Macular thickness from all 9 regions of the ETDRS map was documented for each subject. Variations in macular thickness measurements by age and gender were determined. Results The 220 subjects had a mean age of 45.3 years (16–80 years). Using the ETDRS map, foveal thickness for all subjects was measured to be 229±20.46 µm. Mean macular thickness for all subjects was 262.8±13.34 µm. Male gender was associated with greater foveal (p<0.0001) and mean macular (p<0.0001) thickness compared to females. There was no association of mean macular thickness (r2 = 0.01; p>0.05) and foveal thickness (r2 = 0.00004; p>0.05) with age. Conclusion We have provided normative data for macular thickness using Topcon SD-OCT system. Our results are comparable to some and vary from other reports using the similar OCT system. Our results suggest that male gender is associated with greater macular thickness, while macular thickness has no association with age in healthy eyes. This is the first normative data for macular thickness from Pakistan; benchmark for diagnosing and monitoring macular pathologies. The values obtained in this study may be useful for comparison with other populations, other SD-OCT systems and future imaging technologies.

[1]  Veit Sturm,et al.  Reproducibility of retinal thickness measurements in healthy subjects using spectralis optical coherence tomography. , 2009, American journal of ophthalmology.

[2]  Eun Suk Lee,et al.  Macular thickness variations with sex, age, and axial length in healthy subjects: a spectral domain-optical coherence tomography study. , 2010, Investigative ophthalmology & visual science.

[3]  V. Greenstein,et al.  Structural and functional assessment of the macular region in patients with glaucoma , 2006, British Journal of Ophthalmology.

[4]  C. W. Chan,et al.  Relationship of Gender, Body Mass Index, and Axial Length with Central Retinal Thickness Using Optical Coherence Tomography , 2005, Eye.

[5]  Joan W. Miller,et al.  Reproducibility of retinal thickness measurements on normal and pathologic eyes by different optical coherence tomography instruments. , 2010, American journal of ophthalmology.

[6]  J. Duker,et al.  COMPARISON OF SPECTRAL/FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS FOR ASSESSMENT OF NORMAL MACULAR THICKNESS , 2010, Retina.

[7]  E. Herderick,et al.  Intersession repeatability of macular thickness measurements with the Humphrey 2000 OCT. , 2000, Investigative ophthalmology & visual science.

[8]  L. Pierro,et al.  Macular thickness interoperator and intraoperator reproducibility in healthy eyes using 7 optical coherence tomography instruments. , 2010, American journal of ophthalmology.

[9]  J. Duker,et al.  Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. , 2005, Ophthalmology.

[10]  J. Duker,et al.  Normal macular thickness measurements in healthy eyes using Stratus optical coherence tomography. , 2006, Archives of ophthalmology.

[11]  E Reichel,et al.  Quantitative assessment of macular edema with optical coherence tomography. , 1995, Archives of ophthalmology.

[12]  S. D'Anna,et al.  Noninvasive mapping of the normal retinal thickness at the posterior pole. , 1999, Ophthalmology.

[13]  J. Fujimoto,et al.  Optical coherence tomography of the human retina. , 1995, Archives of ophthalmology.

[14]  Robert J Zawadzki,et al.  Clinical application of rapid serial fourier-domain optical coherence tomography for macular imaging. , 2006, Ophthalmology.

[15]  Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography , 2007, Clinical ophthalmology.

[16]  G. Wollstein,et al.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT. , 2004, Investigative ophthalmology & visual science.

[17]  M. Shahidi,et al.  Retinal thickness analysis for quantitative assessment of diabetic macular edema. , 1991, Archives of ophthalmology.

[18]  S. Sadda,et al.  Macular and Retinal Nerve Fiber Layer Thickness Measurements in Normal Eyes With the Stratus OCT, the Cirrus HD-OCT, and the Topcon 3D OCT-1000 , 2011, Journal of glaucoma.

[19]  Grading diabetic retinopathy from stereoscopic color fundus photographs--an extension of the modified Airlie House classification. ETDRS report number 10. Early Treatment Diabetic Retinopathy Study Research Group. , 1991, Ophthalmology.

[20]  A. Cavallerano,et al.  Racial Differences in Macular Thickness in Healthy Eyes , 2007, Optometry and vision science : official publication of the American Academy of Optometry.

[21]  David Keating,et al.  Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system. , 2002, Investigative ophthalmology & visual science.

[22]  Robert N Weinreb,et al.  Comparison of macular thickness measurements between time domain and spectral domain optical coherence tomography. , 2008, Investigative ophthalmology & visual science.

[23]  Brendan T Barrett,et al.  Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography , 2009, The open ophthalmology journal.

[24]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[25]  J. Duker,et al.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation. , 2004, Optics express.

[26]  Amir H. Kashani,et al.  Retinal thickness analysis by race, gender, and age using Stratus OCT. , 2010, American journal of ophthalmology.

[27]  P. Sony,et al.  Macular thickness evaluation using the optical coherence tomography in normal Indian eyes. , 2004, Indian journal of ophthalmology.

[28]  F L Ferris,et al.  Macular thickening and visual acuity. Measurement in patients with cystoid macular edema. , 1987, Ophthalmology.

[29]  B. Alamouti,et al.  Retinal thickness decreases with age: an OCT study , 2003, The British journal of ophthalmology.

[30]  Vikram S Brar,et al.  Normative data for macular thickness by high-definition spectral-domain optical coherence tomography (spectralis). , 2009, American journal of ophthalmology.

[31]  Giovanni Gregori,et al.  Macular thickness measurements in normal eyes using spectral domain optical coherence tomography. , 2007, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.