Ignition of Wood Fencing Assemblies Exposed to Continuous Wind-Driven Firebrand Showers

Post-fire studies conducted by NIST on the Waldo Canyon Fire in Colorado (2012) determined that wood fencing assemblies are believed to be vulnerable to ignition from firebrand showers in Wildland–Urban Interface fires, but again there has never been any experimental verification of this ignition mechanism. As a result, a series of experiments were conducted to examine ignition of wood fencing assemblies subjected to continuous, wind-driven firebrand showers. Western Red Cedar and Redwood fencing assemblies were exposed to continuous, wind-driven firebrands generated by the NIST full-scale Continuous Feed Firebrand Generator installed in the Fire Research Wind Tunnel Facility at the Building Research Institute in Japan. To simulate fine fuels that may be present near fencing assemblies, dried shredded hardwood mulch beds were placed adjacent to the fencing assemblies. The fencing assemblies were varied in length and in orientation to the applied wind field to simulate a range of configurations that may be encountered in realistic situations. Both flat and corner sections of fencing assemblies were used in these experiments. The dimensions of the flat wood fencing assemblies sections were varied from 0.91 m wide, 1.83 m in height to 1.83 m wide, 1.83 m in height. With respect to the corner sections, the dimensions used were 0.91 m by 0.91 m by 1.83 m in height. All configurations considered resulted in flaming ignition (FI) of the mulch beds, and subsequent FI of the wood fencing assemblies. Finally, experiments were also completed to determine if wind-driven firebrand showers could produce FI of fencing assemblies without the presence of fine fuels adjacent to the fence sections. Firebrands produced smoldering ignition (SI) of the fencing assemblies without fine fuels present, and SI transitioned to FI under the applied wind field. These experiments have demonstrated that wood fencing assemblies are vulnerable to ignition by wind-driven firebrand showers.

[1]  Haihui Wang Analysis on Downwind Distribution of Firebrands Sourced from a Wildland Fire , 2011 .

[2]  Yoshihiko Hayashi,et al.  Mass and size distribution of firebrands generated from burning Korean pine (Pinus koraiensis) trees , 2009 .

[3]  Samuel L. Manzello,et al.  Enabling the Investigation of Structure Vulnerabilities to Wind- Driven Firebrand Showers in Wildland-Urban Interface (WUI) Fires , 2014 .

[4]  Samuel L. Manzello,et al.  Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire , 2014 .

[5]  S. L. Manzello,et al.  The wildland-urban interface fire problem - current approaches and research needs , 2010 .

[6]  Samuel L. Manzello,et al.  Exposing siding treatments, walls fitted with eaves, and glazing assemblies to firebrand showers , 2012 .

[7]  Samuel L. Manzello Special Issue on Wildland–Urban Interface (WUI) Fires , 2014 .

[8]  S. L. Manzello,et al.  Exposing Decking Assemblies to Continuous Wind-Driven Firebrand Showers , 2012 .

[9]  Takeyoshi Tanaka,et al.  Transport Of Disk-shaped Firebrands In A Turbulent Boundary Layer , 2005 .

[10]  R. A. Anthenien,et al.  On the trajectories of embers initially elevated or lofted by small scale ground fire plumes in high winds , 2006 .

[11]  Samuel L. Manzello,et al.  Firebrand Generation Data Obtained from a Full Scale Structure Burn | NIST , 2011 .

[12]  Samuel L. Manzello,et al.  Experimental investigation of structure vulnerabilities to firebrand showers , 2011 .

[13]  Samuel L. Manzello,et al.  Quantifying the vulnerabilities of ceramic tile roofing assemblies to ignition during a firebrand attack , 2010 .

[14]  Yoshihiko Hayashi,et al.  On the Use of a Firebrand Generator to Investigate the Ignition of Structures in Wildland-Urban Interface (WUI) Fires. | NIST , 2007 .

[15]  Craig L. Beyler,et al.  Development of Test Methods for Assessing the Fire Hazards of Landscaping Mulch , 2014 .

[16]  T. J. Ohlemiller,et al.  Smoldering Combustion Propagation On Solid Wood , 1991 .

[17]  I. K. Knight The Design and Construction of a Vertical Wind Tunnel for the Study of Untethered Firebrands in Flight , 2001 .

[18]  Samuel L. Manzello,et al.  Ignition of Mulch Beds Exposed to Continuous Wind-Driven Firebrand Showers , 2015 .

[19]  Samuel L. Manzello,et al.  Experimentally Simulating Wind Driven Firebrand Showers in Wildland-urban Interface (WUI) Fires: Overview of the NIST Firebrand Generator (NIST Dragon) Technology , 2013 .

[20]  A. Carlos Fernandez-Pello,et al.  On the flight paths of metal particles and embers generated by power lines in high winds--a potential source of wildland fires , 1998 .

[21]  Carlos Sánchez Tarifa,et al.  On the flight pahts and lifetimes of burning particles of wood , 1965 .

[22]  Samuel L. Manzello,et al.  Comparison Testing Protocol for Firebrand Penetration through Building Vents: Summary of BRI/NIST Full Scale and NIST Reduced Scale Results | NIST , 2010 .

[23]  Erik L. Johnsson,et al.  Wildland-Urban Interface Fire Research Needs : Workshop Summary Report , 2013 .

[24]  F. Usda,et al.  Transport of Firebrands by Line Thermals , 1983 .

[25]  Samuel L. Manzello,et al.  Enabling the study of structure vulnerabilities to ignition from wind driven firebrand showers: A summary of experimental results , 2012 .