Steady-state MR imaging sequences: physics, classification, and clinical applications.

Steady-state sequences are a class of rapid magnetic resonance (MR) imaging techniques based on fast gradient-echo acquisitions in which both longitudinal magnetization (LM) and transverse magnetization (TM) are kept constant. Both LM and TM reach a nonzero steady state through the use of a repetition time that is shorter than the T2 relaxation time of tissue. When TM is maintained as multiple radiofrequency excitation pulses are applied, two types of signal are formed once steady state is reached: preexcitation signal (S-) from echo reformation; and postexcitation signal (S+), which consists of free induction decay. Depending on the signal sampled and used to form an image, steady-state sequences can be classified as (a) postexcitation refocused (only S+ is sampled), (b) preexcitation refocused (only S- is sampled), and (c) fully refocused (both S+ and S- are sampled) sequences. All tissues with a reasonably long T2 relaxation time will show additional signals due to various refocused echo paths. Steady-state sequences have revolutionized cardiac imaging and have become the standard for anatomic functional cardiac imaging and for the assessment of myocardial viability because of their good signal-to-noise ratio and contrast-to-noise ratio and increased speed of acquisition. They are also useful in abdominal and fetal imaging and hold promise for interventional MR imaging. Because steady-state sequences are now commonly used in MR imaging, radiologists will benefit from understanding the underlying physics, classification, and clinical applications of these sequences.

[1]  Tohru Kurabayashi,et al.  Trigeminal neuralgia: evaluation of neuralgic manifestation and site of neurovascular compression with 3D CISS MR imaging and MR angiography. , 2003, Radiology.

[2]  A. O. Rodríguez,et al.  Principles of magnetic resonance imaging , 2004 .

[3]  M. Gyngell,et al.  The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences. , 1988, Magnetic resonance imaging.

[4]  O. Simonetti,et al.  Three‐dimensional breathhold SSFP coronary MRA: A comparison between 1.5T and 3.0T , 2005, Journal of magnetic resonance imaging : JMRI.

[5]  R R Edelman,et al.  Technologic advances in abdominal MR imaging. , 2001, Radiology.

[6]  K. Scheffler,et al.  Is TrueFISP a gradient‐echo or a spin‐echo sequence? , 2003, Magnetic resonance in medicine.

[7]  F Eckstein,et al.  Double echo steady state magnetic resonance imaging of knee articular cartilage at 3 Tesla: a pilot study for the Osteoarthritis Initiative , 2005, Annals of the rheumatic diseases.

[8]  Giles R. Scuderi,et al.  The Basic Principles , 2006 .

[9]  T. Jaspan,et al.  High resolution CISS imaging of the spine. , 2001, The British journal of radiology.

[10]  F. Barkhof,et al.  Detection of Root Avulsion in the Dominant C7 Obstetric Brachial Plexus Lesion: Experience with Three-dimensional Constructive Interference in Steady-state Magnetic Resonance Imaging and Electrophysiology , 2005, Neurosurgery.

[11]  Jens Frahm,et al.  Rapid Scan Techniques. , 1998 .

[12]  Robert R. Edelman,et al.  Advanced Imaging Techniques Including Fast Imaging , 2005 .

[13]  Gerhard Laub,et al.  TrueFISP--technical considerations and cardiovascular applications. , 2003, European journal of radiology.

[14]  [Differentiation of benign osteoporotic and neoplastic vertebral compression fractures with a diffusion-weighted, steady-state free precession sequence]. , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[15]  J S Lewin,et al.  Fast T2‐weighted imaging by PSIF at 0.2 T for interventional MRI , 1999, Magnetic resonance in medicine.

[16]  K. Hoffmann,et al.  CSF flow imaging in the management of third ventriculostomy with a reversed fast imaging with steady-state precession sequence , 2003, European Radiology.

[17]  Debiao Li,et al.  Magnetic resonance angiography of coronary arteries with a 3-dimensional magnetization-prepared true fast imaging with steady-state precession sequence compared with conventional coronary angiography. , 2005, American heart journal.

[18]  J. Finn,et al.  Cardiac MR imaging: state of the technology. , 2006, Radiology.

[19]  M. Reiser,et al.  Differenzierung osteoporotischer und tumoröser Wirbelkörperfrakturen mit einer diffusionsgewichteten steady-state free precession-sequenz , 2002 .

[20]  N Hosten,et al.  CSF flow studies of intracranial cysts and cyst-like lesions achieved using reversed fast imaging with steady-state precession MR sequences. , 2000, AJNR. American journal of neuroradiology.

[21]  K. Scheffler,et al.  Principles and applications of balanced SSFP techniques , 2003, European Radiology.

[22]  O. Simonetti,et al.  Real‐time cardiac cine imaging with SPIDER: Steady‐state projection imaging with dynamic echo‐train readout , 2001, Magnetic resonance in medicine.

[23]  H. Brueckmann,et al.  Cavernous Malformations of the Brainstem: Three-Dimensional-Constructive Interference in Steady-State Magnetic Resonance Imaging for Improvement of Surgical Approach and Clinical Results , 2006, Neurosurgery.

[24]  Jeffrey L Duerk,et al.  Comparison of ECG-gated rectilinear vs. real-time radial K-space sampling schemes in cine True-FISP cardiac MRI. , 2004, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[25]  W. Nitz,et al.  Fast and ultrafast non-echo-planar MR imaging techniques , 2002, European Radiology.

[26]  Jeffrey L Duerk,et al.  Comparison of MR imaging sequences for liver and head and neck interventions: is there a single optimal sequence for all purposes? , 2004, Academic radiology.

[27]  B. Tomandl,et al.  MR cisternography: a new method for the diagnosis of CSF fistulae , 1997, European Radiology.

[28]  W. Nitz,et al.  MR imaging: acronyms and clinical applications , 1999, European Radiology.

[29]  R A Zimmerman,et al.  T2-Weighted fast MR imaging with true FISP versus HASTE: comparative efficacy in the evaluation of normal fetal brain maturation. , 2000, AJR. American journal of roentgenology.

[30]  D G Nishimura,et al.  Analysis and Reduction of the Transient Response in SSFP Imaging , 2000 .

[31]  T Metens,et al.  Fat attenuation using a dual steady‐state balanced‐SSFP sequence with periodically variable flip angles , 2006, Magnetic resonance in medicine.

[32]  P. Jayakumar,et al.  3D steady-state MR cisternography in CSF rhinorrhoea. , 2001, Acta radiologica.

[33]  Pulsatile motion artifact reduction in 3D steady-state-free-precession-echo brain imaging. , 1993, Magnetic resonance imaging.

[34]  Debiao Li,et al.  Reduction of transient signal oscillations in true‐FISP using a linear flip angle series magnetization preparation , 2003, Magnetic resonance in medicine.

[35]  P. Lauterbur,et al.  Principles of magnetic resonance imaging : a signal processing perspective , 1999 .

[36]  E M Haacke,et al.  Fast MR imaging: techniques and clinical applications. , 1990, AJR. American journal of roentgenology.

[37]  R. Edelman,et al.  Clinical magnetic resonance imaging , 1990 .

[38]  R. Semelka,et al.  MR imaging abbreviations, definitions, and descriptions: a review. , 1999, Radiology.

[39]  Diego R. Martín,et al.  Magnetic Resonance Imaging of the Gastrointestinal Tract , 2005, Topics in magnetic resonance imaging : TMRI.