Microneedle array for transdermal biological fluid extraction and in situ analysis

Abstract This paper presents the design, fabrication and testing of a hollow microneedle array with integrated, fluidic microchannels. The microneedles are machined from single crystal silicon to a shank height of 250–350 μm with 300 μm center-to-center spacing. The needle size, density and shape are controlled by independent processing steps. Piercing of the protective stratum corenum layer of the skin by the microneedles, providing access to the living epithelial layers underneath, is successfully demonstrated. Filling of the integrated microchannels by capillary action with both non-biological fluids (glycerol, ethanol, surrogate interstitial fluid (ISF) and water) as well as biological fluids (ISF and whole blood) is demonstrated. The ability to extract interstitial fluid from human skin is successfully achieved and verified by the in situ measurement of glucose concentration. The microchip presented here represents the first step towards the realization of a transdermal, ISF extraction and analysis microsystem.

[1]  P. Elias The stratum corneum as an organ of protection: old and new concepts. , 1989, Current problems in dermatology.

[2]  R Smith,et al.  Electrophoresis separation in open microchannels. A method for coupling electrophoresis with MALDI-MS. , 2001, Analytical chemistry.

[3]  Assessment of tissue reactions to biomaterials: a model system using the foreign body response in the mouse lung to intravenously injected divinyl copolymer beads. , 1984, Journal of biomedical materials research.

[4]  Regina Luttge,et al.  Silicon micromachined hollow microneedles for transdermal liquid transport , 2003 .

[5]  S. Ghandhi VLSI fabrication principles : sil-icon and gallium arsenide , 1994 .

[6]  M. Allen,et al.  Microfabricated microneedles: a novel approach to transdermal drug delivery. , 1998, Journal of pharmaceutical sciences.

[7]  Shankar Chandrasekaran,et al.  Surface micromachined metallic microneedles , 2003 .

[8]  Shan Huang,et al.  The biocompatibility, integrity, and positional stability of an injectable microstimulator for reanimation of the paralyzed larynx , 2001, IEEE Transactions on Biomedical Engineering.

[9]  R. Mathies,et al.  Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis. , 2001, Lab on a chip.

[10]  G. Stemme,et al.  Novel, side opened out-of-plane microneedles for microfluidic transdermal interfacing , 2002, Technical Digest. MEMS 2002 IEEE International Conference. Fifteenth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.02CH37266).

[11]  M. Burns,et al.  Microfabricated capillarity-driven stop valve and sample injector , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[12]  W H Smart,et al.  The use of silicon microfabrication technology in painless blood glucose monitoring. , 2000, Diabetes technology & therapeutics.

[13]  G. Wallis,et al.  Field Assisted Glass‐Metal Sealing , 1969 .

[14]  K. Horch,et al.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array , 1991, IEEE Transactions on Biomedical Engineering.