Design and analysis of orthogonally compliant features for local contact pressure relief in transtibial prostheses.

A very attractive advantage of manufacturing prosthetic sockets using solid freeform fabrication is the freedom to introduce design solutions that would be difficult to implement using traditional manufacturing techniques. Such is the case with compliant features embedded in amputee prosthetic sockets to relieve contact pressure at the residual limb-socket interface. The purpose of this study was to present a framework for designing compliant features to be incorporated into transtibial sockets and manufacturing prototypes using selective laser sintering (SLS) and Duraform material. The design process included identifying optimal compliant features using topology optimization algorithms and integrating these features within the geometry of the socket model. Using this process, a compliant feature consisting of spiral beams and a supporting external structure was identified. To assess its effectiveness in reducing residual limb-socket interface pressure, a case study was conducted using SLS manufactured prototypes to quantify the difference in interface pressure while a patient walked at his self-selected pace with one noncompliant and two different compliant sockets. The pressure measurements were performed using thin pressure transducers located at the distal tibia and fibula head. The measurements revealed that the socket with the greatest compliance reduced the average and peak pressure by 22% and 45% at the anterior side distal tibia, respectively, and 19% and 23% at the lateral side of the fibula head, respectively. These results indicate that the integration of compliant features within the socket structure is an effective way to reduce potentially harmful contact pressure and increase patient comfort.

[1]  K. Svanberg The method of moving asymptotes—a new method for structural optimization , 1987 .

[2]  M. Bendsøe,et al.  Material interpolation schemes in topology optimization , 1999 .

[3]  A W Buis,et al.  Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a transtibial amputee , 1998, Prosthetics and orthotics international.

[4]  Aft Mak,et al.  State-of-the-art research in lower-limb prosthetic biomechanics-socket interface , 2001 .

[5]  A F Mak,et al.  State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review. , 2001, Journal of rehabilitation research and development.

[6]  Jack L. Lancaster,et al.  A Computerized System to Manufacture Prostheses for Amputees in Developing Countries , 1989 .

[7]  J. Petersson,et al.  Numerical instabilities in topology optimization: A survey on procedures dealing with checkerboards, mesh-dependencies and local minima , 1998 .

[8]  Mario Carneiro Faustimi Modeling and fabrication of prosthetic sockets using selective laser sintering , 2004 .

[9]  Noboru Kikuchi,et al.  TOPOLOGY OPTIMIZATION OF COMPLIANT MECHANISMS USING THE HOMOGENIZATION METHOD , 1998 .

[10]  M. Bendsøe,et al.  Generating optimal topologies in structural design using a homogenization method , 1988 .

[11]  B. Bahr,et al.  Design and suction cup analysis of a wall climbing robot , 1996 .

[12]  M. Legro,et al.  Issues of importance reported by persons with lower limb amputations and prostheses. , 1999, Journal of rehabilitation research and development.

[13]  Mario C Faustini,et al.  The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods. , 2006, Medical engineering & physics.

[14]  Joseph J. Beaman,et al.  Fabrication of Prosthetic Socket by Selective Laser Sintering , 1991 .

[15]  Klaus Hackl,et al.  Numerical instabilities in structural optimization – analogy between topology & shape design problems , 2006 .

[16]  Ole Sigmund,et al.  A 99 line topology optimization code written in Matlab , 2001 .

[17]  N. Kikuchi,et al.  A homogenization method for shape and topology optimization , 1991 .