Autonomous Heart Rate Tracking Methodology Using Kalman Filter and the EM Algorithm

Accurate heart rate monitoring during intense physical activity is a challenging problem due to high levels of motion artifacts (MA) in sensors that rely on stable physical proximity/contact for accurate measurement extraction. Photo-plethysmography (PPG) sensor is a non-invasive optical sensor that is widely used in wearable devices, such as smartwatches, to measure blood volume changes using the property of light reflection and absorption; these measurements can be used to extract the heart rate (HR) of an individual wearing that device. The PPG sensor is susceptible to the motion artifact which increases with physical activity. Since the frequency of the motion artifact is very close to the range of HR, estimation of HR information becomes very challenging. As a result, MA removal remains an active research topic over the last few years. Several approaches have been developed in the recent past for MA removal and accurate HR estimation. Among these recent works, a Kalman Filter (KF) based approach showed promising results for accurate estimation and tracking of HR based on PPG measurements. However, the previous KF based HR tracker was demonstrated for a particular dataset with manually tuned filter parameters. Such a custom tuned approach might not perform accurately in practical scenarios where the amount of motion artifact and the heart-rate variability depend on numerous, unpredictable factors. In this paper, we develop an approach to automatically tune the KF based HR tracker based on the expectation maximization (EM) algorithm. The applicability of the proposed approach is demonstrated using an open-source PPG database that was recorded during varying pre-determined physical activities.

[1]  Hyonyoung Han,et al.  Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  K. Reddy,et al.  Motion Artifact Reduction in Photoplethysmographic Signals using Singular Value Decomposition , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.

[3]  Jo Woon Chong,et al.  Photoplethysmograph Signal Reconstruction Based on a Novel Hybrid Motion Artifact Detection–Reduction Approach. Part I: Motion and Noise Artifact Detection , 2014, Annals of Biomedical Engineering.

[4]  Takashi Sato,et al.  PARHELIA: Particle Filter-Based Heart Rate Estimation From Photoplethysmographic Signals During Physical Exercise , 2018, IEEE Transactions on Biomedical Engineering.

[5]  Zhilin Zhang,et al.  TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise , 2014, IEEE Transactions on Biomedical Engineering.

[6]  Haruki Kawanaka,et al.  Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Suiren Wan,et al.  SFST: A robust framework for heart rate monitoring from photoplethysmography signals during physical activities , 2017, Biomed. Signal Process. Control..

[8]  Sun K. Yoo,et al.  Motion artifact reduction in photoplethysmography using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[9]  G. McLachlan,et al.  The EM algorithm and extensions , 1996 .

[10]  Bruce J. Gluckman,et al.  Challenges in wearable personal health monitoring systems , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[12]  Yuan-Ting Zhang,et al.  Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter , 2002, Proceedings of IEEE Sensors.

[13]  HyunSoon Shin,et al.  Effective PPG sensor placement for reflected red and green light, and infrared wristband-type photoplethysmography , 2016, 2016 18th International Conference on Advanced Communication Technology (ICACT).

[14]  B. Li,et al.  Non-contact detection of oxygen saturation based on visible light imaging device using ambient light. , 2013, Optics express.

[15]  G. Giorgi,et al.  Robust estimation and tracking of heart rate by PPG signal analysis , 2017, 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[16]  Andriy Temko,et al.  Accurate Heart Rate Monitoring During Physical Exercises Using PPG , 2017, IEEE Transactions on Biomedical Engineering.

[17]  Larry Katz,et al.  Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise , 2017, Medicine and science in sports and exercise.

[18]  Marimuthu Palaniswami,et al.  Robust Heart Rate Estimation During Physical Exercise Using Photoplethysmographic Signals , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[19]  Zhilin Zhang,et al.  Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction , 2015, IEEE Transactions on Biomedical Engineering.

[20]  Jeff A. Bilmes,et al.  A gentle tutorial of the em algorithm and its application to parameter estimation for Gaussian mixture and hidden Markov models , 1998 .

[21]  W. Marsden I and J , 2012 .

[22]  R. Shumway,et al.  Time Series Regression and Exploratory Data Analysis , 2011 .

[23]  Revathy Pambungal Sivadas,et al.  A Robust Algorithm for Estimating Heart-Rate from Motion-Corrupted Photoplethysmographic Signals Using Adaptive Filtering and Nonparametric Spectrum Estimation , 2018 .

[24]  Jo Woon Chong,et al.  Photoplethysmograph Signal Reconstruction based on a Novel Motion Artifact Detection-Reduction Approach. Part II: Motion and Noise Artifact Removal , 2014, Annals of Biomedical Engineering.

[25]  Farrokh Marvasti,et al.  Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise with Simultaneous Accelerometry , 2015, IEEE Signal Processing Letters.

[26]  M. Bolic,et al.  Arterial blood pressure parameter estimation and tracking using particle filters , 2011, 2011 IEEE International Symposium on Medical Measurements and Applications.

[27]  Toshiyo Tamura,et al.  Relationship Between Measurement Site and Motion Artifacts in Wearable Reflected Photoplethysmography , 2011, Journal of Medical Systems.

[28]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[29]  Md. Kamrul Hasan,et al.  A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion Artifacts , 2016, IEEE Transactions on Biomedical Engineering.