Performance of a Solar Chimney Under Egyptian Weather Conditions: Numerical Simulation and Experimental Validation

High solar radiation and ambient temperature, and large desert in Egypt are excellent conditions to install efficiently solar chimney power plants there. Therefore this research aimed to develop a validated mathematical model and governing equations of solar chimney. It is proposed to improve the performance of solar chimney under effects of various parameters, and study of possibility of installing solar chimney in Egypt. The mathematical simulation of the solar chimney has been developed including all its performance parameters, dimensions (of collector, chimney and turbine) and the metrological data; which were considered as inputs of the simulation program. A comparison between the mathematical and experimental performance has been investigated to validate the mathematical simulation. The mathematical model has been used to predict the performance of the solar chimney power plant over a year in Egypt. It is used to study of effects of geometrical parameters, and investigate possibility of the optimum geometrical dimensions. It is obtained that there is in fact no optimum physical size for such plants without considering the economical constraints. The chimney height has a significant effect in the chimney performance. Visualizing of annual performance of the solar chimney would seem to be essentially a power generator in Egypt if it installed in a large scale.Key words: Solar chimney; Numerical simulation; Annual performance; Experimental validation; Optimization

[1]  E. Bilgen,et al.  Solar chimney power plants for high latitudes , 2005 .

[2]  Theodor W. von Backström,et al.  Analysis of some available heat transfer coefficients applicable to solar chimney power plant collectors , 2009 .

[3]  S. A. Sherif,et al.  On a simple analytical model for solar chimneys , 1999 .

[4]  Liu Wei,et al.  Numerical simulation of the solar chimney power plant systems coupled with turbine , 2008 .

[5]  L. B. Mullett The solar chimney—overall efficiency, design and performance , 1987 .

[6]  Xinping Zhou,et al.  Analysis of chimney height for solar chimney power plant , 2009 .

[7]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[8]  S. A. Sherif,et al.  Experimental and theoretical performance of a demonstration solar chimney model—Part I: mathematical model development , 1998 .

[9]  Theodor W. von Backström,et al.  Solar Chimney cycle analysis with system loss and solar collector performance. , 2000 .

[10]  Theodor W. von Backström,et al.  Maximum fluid power condition in solar chimney power plants - An analytical approach , 2006 .

[11]  Ramon Molina Valle,et al.  Theoretical evaluation of the influence of geometric parameters and materials on the behavior of the airflow in a solar chimney , 2009 .

[12]  T. W. von Backström,et al.  Performance analysis of the power conversion unit of a solar chimney power plant , 2008 .

[13]  W. Haaf,et al.  Solar Chimneys: Part II: Preliminary Test Results from the Manzanares Pilot Plant , 1984 .

[14]  J. Schlaich,et al.  Solar Chimneys Part I: Principle and Construction of the Pilot Plant in Manzanares , 1983 .

[15]  M. A. dos S. Bernardes,et al.  Thermal and technical analyses of solar chimneys , 2003 .