Power Quality Management of PV Power Plant With Transformer Integrated Filtering Method

This paper presents a new solution of power quality management for the photovoltaic (PV) power plant with the transformer integrated filtering method. The innovation of the PV power plant is that it contains two-stage filtering station, which consists of a box-type transformer with integrated filter and a 110 kV grid-connected transformer based on inductive filtering method. The filtering reactor can be integrated into the box-type transformer as a decoupled winding, so that the modular design of the box-type transformer and the passive filter is realized. Inductive filtering method applied in the grid-connected transformer not only improves the power quality at the point of common coupling, but dampens the harmonic resonance between the passive filter and grid. The hierarchical structure of the PV power plant is introduced firstly. Then, the equivalent circuit model and the mathematical model of the primary and secondary filtering stations are established, respectively. Moreover, the influence of the weak coupling of integrated reactor on the filtering performance is analyzed. The antijamming capabilities of the inductive filtering method and the traditional filtering method are compared under the condition of parameter disturbance. At last, the site tests of the PV power plant with transformer integrated filtering method are made, which show that the PV grid-connected system comprised of the two-stage filtering station has the characteristics of low harmonic emission, high power factor, and stable operation.

[1]  Debra Lew,et al.  Reaching new solar heights: integrating high penetrations of PV into the power system , 2017 .

[2]  Iqbal Husain,et al.  Reactive Power Management for Overvoltage Prevention at High PV Penetration in a Low-Voltage Distribution System , 2017 .

[3]  Hui Li,et al.  Integrated Size and Energy Management Design of Battery Storage to Enhance Grid Integration of Large-Scale PV Power Plants , 2018, IEEE Transactions on Industrial Electronics.

[4]  J.C. Das,et al.  Passive filters - potentialities and limitations , 2003, IEEE Transactions on Industry Applications.

[5]  Luis García de Vicuña,et al.  Reduction of Current Harmonic Distortion in Three-Phase Grid-Connected Photovoltaic Inverters via Resonant Current Control , 2013, IEEE Transactions on Industrial Electronics.

[6]  Lu Wang,et al.  A 60-kW 3-kW/kg Five-Level T-Type SiC PV Inverter With 99.2% Peak Efficiency , 2017, IEEE Transactions on Industrial Electronics.

[7]  Makbul Anwari,et al.  Photovoltaic plant with reduced output current harmonics using generation-side active power conditioner , 2014 .

[8]  Bin Wu,et al.  Resonance Damping and Harmonic Suppression for Grid-Connected Current-Source Converter , 2014, IEEE Transactions on Industrial Electronics.

[9]  Yong Li,et al.  A controllable inductive power filtering system: modeling, analysis and control design , 2019 .

[10]  Zhengyou He,et al.  Potential Harmonic Resonance Impacts of PV Inverter Filters on Distribution Systems , 2015, IEEE Transactions on Sustainable Energy.

[11]  Bikash Pal,et al.  Harmonic Domain Modeling of PV System for the Assessment of Grid Integration Impact , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[12]  Fang Liu,et al.  A Virtual Impedance Comprehensive Control Strategy for the Controllably Inductive Power Filtering System , 2017, IEEE Transactions on Power Electronics.

[13]  Vinod John,et al.  Mitigation of Lower Order Harmonics in a Grid-Connected Single-Phase PV Inverter , 2013, IEEE Transactions on Power Electronics.

[14]  Fujun Ma,et al.  Large-scale photovoltaic plant harmonic transmission model and analysis on resonance characteristics , 2015 .

[15]  Pedro Rodriguez,et al.  Impact of 100-MW-scale PV plants with synchronous power controllers on power system stability in northern Chile , 2017 .

[16]  Yijia Cao,et al.  Power Quality Improvement and LVRT Capability Enhancement of Wind Farms by Means of an Inductive Filtering Method , 2016 .

[17]  Oriol Gomis-Bellmunt,et al.  Power plant control in large-scale photovoltaic plants: design, implementation and validation in a 9.4 MW photovoltaic plant , 2016 .

[18]  Longfu Luo,et al.  A new method highly integrated with converter transformer for harmonic suppression and reactive power compensation , 2014, 2014 International Conference on Power System Technology.

[19]  Rolando Burgos,et al.  Multimega VAR Passive Filters for Mining Applications: Practical Limitations and Technical Considerations , 2015, IEEE Transactions on Industry Applications.

[20]  Sijia Hu,et al.  Power quality improvement using controllable inductive power filtering method for industrial DC supply system , 2019, Control Engineering Practice.

[21]  Yong Li,et al.  An Industrial DC Power Supply System Based on an Inductive Filtering Method , 2012, IEEE Transactions on Industrial Electronics.

[22]  C. Liang,et al.  An integrated harmonic-filtering transformer for low-voltage distribution systems , 2015, 2015 IEEE Magnetics Conference (INTERMAG).