Numerical prediction of peri-implant bone adaptation: Comparison of mechanical stimuli and sensitivity to modeling parameters.

Long term durability of osseointegrated implants depends on bone adaptation to stress and strain occurring in proximity of the prosthesis. Mechanical overloading, as well as disuse, may reduce the stability of implants by provoking bone resorption. However, an appropriate mechanical environment can improve integration. Several studies have focused on the definition of numerical methods to predict bone peri-implant adaptation to the mechanical environment. Existing adaptation models differ notably in the type of mechanical variable adopted as stimulus but also in the bounds and shape of the adaptation rate equation. However, a general comparison of the different approaches on a common benchmark case is still missing and general guidelines to determine physically sound parameters still need to be developed. This current work addresses these themes in two steps. Firstly, the histograms of effective stress, strain and strain energy density are compared for rat tibiae in physiological (homeostatic) conditions. According to the Mechanostat, the ideal stimulus should present a clearly defined, position and tissue invariant lazy zone in homeostatic conditions. Our results highlight that only the octahedral shear strain presents this characteristic and can thus be considered the optimal choice for implementation of a continuum level bone adaptation model. Secondly, critical modeling parameters such as lazy zone bounds, type of rate equation and bone overloading response are classified depending on their influence on the numerical predictions of bone adaptation. Guidelines are proposed to establish the dominant model parameters based on experimental and simulated data.

[1]  A. Terrier,et al.  Adaptation Models of Anisotropic Bone. , 1997, Computer methods in biomechanics and biomedical engineering.

[2]  U C Belser,et al.  Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. , 2004, Clinical oral implants research.

[3]  H. Frost Bone “mass” and the “mechanostat”: A proposal , 1987, The Anatomical record.

[4]  H. Grootenboer,et al.  Adaptive bone-remodeling theory applied to prosthetic-design analysis. , 1987, Journal of biomechanics.

[5]  T. Albrektsson,et al.  Reasons for marginal bone loss around oral implants. , 2012, Clinical implant dentistry and related research.

[6]  Li Shi,et al.  A mathematical model for simulating the bone remodeling process under mechanical stimulus. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[7]  Hsuan-Yu Chou,et al.  Predictions of bone remodeling around dental implant systems. , 2008, Journal of biomechanics.

[8]  J. Botsis,et al.  Factors affecting subject-specific finite element models of implant-fitted rat bone specimens: critical analysis of a technical protocol , 2014, Computer methods in biomechanics and biomedical engineering.

[9]  Patrick J Prendergast,et al.  Bone remodelling algorithms incorporating both strain and microdamage stimuli. , 2007, Journal of biomechanics.

[10]  D. Carter,et al.  Relationships between loading history and femoral cancellous bone architecture. , 1989, Journal of biomechanics.

[11]  P J Prendergast,et al.  Biophysical stimuli on cells during tissue differentiation at implant interfaces , 1997 .

[12]  M W Otter,et al.  Mechanotransduction in bone: do bone cells act as sensors of fluid flow? , 1994, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[13]  B. Snyder,et al.  Compressive axial mechanical properties of rat bone as functions of bone volume fraction, apparent density and micro-ct based mineral density. , 2010, Journal of biomechanics.

[14]  K. Ito,et al.  Analysis of bone architecture sensitivity for changes in mechanical loading, cellular activity, mechanotransduction, and tissue properties , 2011, Biomechanics and modeling in mechanobiology.

[15]  R. Huiskes,et al.  Proposal for the regulatory mechanism of Wolff's law , 1995, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[16]  J. Domínguez,et al.  Numerical estimation of bone density and elastic constants distribution in a human mandible. , 2007, Journal of biomechanics.

[17]  Ralph Müller,et al.  Strain-adaptive in silico modeling of bone adaptation--a computer simulation validated by in vivo micro-computed tomography data. , 2013, Bone.

[18]  J. Botsis,et al.  Peri-implant bone adaptations to overloading in rat tibiae: experimental investigations and numerical predictions. , 2016, Clinical oral implants research.

[19]  K. Hayashi,et al.  Delay of intracortical bone remodelling following a stress change: a theoretical and experimental study. , 2002, Clinical biomechanics.

[20]  S. Durual,et al.  Implementation of the "loaded implant" model in the rat using a miniaturized setup--description of the method and first results. , 2012, Clinical oral implants research.

[21]  W H Harris,et al.  Limitations of the continuum assumption in cancellous bone. , 1988, Journal of biomechanics.

[22]  Jonathan A. Dantzig,et al.  Mechanics of Materials and Structures DISSIPATION ENERGY AS A STIMULUS FOR CORTICAL BONE ADAPTATION , 2011 .

[23]  G S Beaupré,et al.  An approach for time‐dependent bone modeling and remodeling—theoretical development , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[24]  J. Galante,et al.  ESB Research Award 1992. The mechanism of bone remodeling and resorption around press-fitted THA stems. , 1993, Journal of biomechanics.

[25]  J. Botsis,et al.  Influence of gait loads on implant integration in rat tibiae: experimental and numerical analysis. , 2014, Journal of biomechanics.

[26]  Marco Piccinini,et al.  Prediction of peri-implant bone adaptation to mechanical environments , 2014 .

[27]  H. Grootenboer,et al.  The behavior of adaptive bone-remodeling simulation models. , 1992, Journal of biomechanics.

[28]  U. Belser,et al.  Bone reactions to controlled loading of endosseous implants: a pilot study. , 2008, Clinical Oral Implants Research.

[29]  E Guglielmino,et al.  Numerical analysis of bone adaptation around an oral implant due to overload stress , 2004, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[30]  P. Prendergast,et al.  A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading. , 2002, Journal of biomechanics.

[31]  J. Botsis,et al.  External Mechanical Microstimuli Modulate the Osseointegration of Titanium Implants in Rat Tibiae , 2013, BioMed research international.