A Physics-Based (Verilog-A) Compact Model for DC, Quasi-Static Transient, Small-Signal, and Noise Analysis of MOSFET-Based pH Sensors

High-resolution pH measurement is important for biomedical, food, pharmaceutical industries as well as agricultural/environmental monitoring. Among the pH-meters, FET sensors (pH-FETs) offer several advantages, such as, higher sensitivity, lower cost, and smaller size. In this paper, we develop a physics-based (Verilog-A) compact model to simulate dc, quasi-static transient, small-signal, and noise performance of pH-FET sensors. The Verilog-A implementation would allow pH-FET integration with complex signal processing circuits, and prediction of the integrated performance. The model predicts that FET thermal noise dominates in subthreshold, while FET flicker noise dominates above threshold. The minimum pH resolution is dictated by an interplay of FET and electrolyte noise sources, which are in turn functions of transistor geometry and operating condition. For a given technology node, if the sensor is designed to operate in subthreshold regime, pH-FET with shorter but wider channel has better pH resolution. In contrast, for sensor designed to operate in the inversion regime, longer and wider channel is preferred. Finally, we demonstrate the utility of the Verilog-A implementation by circuit simulation of a low-power sensor interface.

[1]  Sergio Martinoia,et al.  Modeling H/sup +/-sensitive FETs with SPICE , 1992 .

[2]  Andreas Hierlemann,et al.  A Verilog-A model for silicon nanowire biosensors: From theory to verification , 2013 .

[3]  Robert D. Harter,et al.  Effect of Soil pH on Adsorption of Lead, Copper, Zinc, and Nickel , 1983 .

[4]  Wei Zhao Predictive technology modeling for scaled CMOS , 2009 .

[5]  Bernard P. Puc,et al.  An integrated semiconductor device enabling non-optical genome sequencing , 2011, Nature.

[6]  V. Torchilin,et al.  "SMART" drug delivery systems: double-targeted pH-responsive pharmaceutical nanocarriers. , 2006, Bioconjugate chemistry.

[7]  Jonghyun Go,et al.  The future scalability of pH-based genome sequencers: A theoretical perspective , 2013 .

[8]  Piyush Dak,et al.  Non-faradaic impedance characterization of an evaporating droplet for microfluidic and biosensing applications. , 2014, Lab on a chip.

[9]  Sergio Martinoia,et al.  Modelling non-ideal behaviours in H+-sensitive FETs with SPICE , 1992 .

[10]  C. Hu,et al.  A unified model for the flicker noise in metal-oxide-semiconductor field-effect transistors , 1990 .

[11]  Piyush Dak,et al.  FET pH Sensor Model , 2015 .

[12]  Sergio Martinoia,et al.  ION SENSITIVE FIELD EFFECT TRANSISTOR ( ISFET ) MODEL IMPLEMENTED IN SPICE , 2007 .

[13]  Juan Santana,et al.  A capacitive MEMS Veriloga-Based Sensor System for Building Integrity Monitoring , 2011, Int. J. Inf. Acquis..

[14]  Barry Merriman,et al.  Progress in Ion Torrent semiconductor chip based sequencing , 2012, Electrophoresis.

[15]  Ivan Novak,et al.  How Severe Acidosis Can a Human Survive? Successful Hemofiltration Use , 2007 .

[16]  J. Eijkel,et al.  A general model to describe the electrostatic potential at electrolyte oxide interfaces , 1996 .

[17]  Ken Kundert,et al.  The designer's guide to Verilog-AMS , 2004 .

[18]  Muhammad A. Alam,et al.  Performance limits of nanobiosensors , 2006 .

[19]  Piet Bergveld,et al.  Thirty years of ISFETOLOGY ☆: What happened in the past 30 years and what may happen in the next 30 years , 2003 .

[20]  Jonghyun Go,et al.  Theory of signal and noise in double-gated nanoscale electronic pH sensors. , 2012, Journal of applied physics.

[21]  P.K. Chatterjee,et al.  An Investigation of the Charge Conservation Problem for MOSFET Circuit Simulation , 1983, IEEE Journal of Solid-State Circuits.

[22]  Eric M. Vogel,et al.  SPICE macromodel of silicon-on-insulator-field-effect-transistor-based biological sensors , 2012 .

[23]  M. J. Deen,et al.  Noise considerations in field-effect biosensors , 2006 .

[24]  Muhammad A. Alam,et al.  Physics-based compact models for insulated-gate field-effect biosensors, landau-transistors, and thin-film solar cells , 2015, 2015 IEEE Custom Integrated Circuits Conference (CICC).

[25]  Piet Bergveld,et al.  On the impedance of the silicon dioxide/electrolyte interface , 1983 .

[26]  Nitin K. Rajan,et al.  Optimal signal-to-noise ratio for silicon nanowire biochemical sensors. , 2011, Applied physics letters.

[27]  J. Haveman,et al.  The relevance of tumour pH to the treatment of malignant disease. , 1984, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  Jonghyun Go,et al.  Extended-gate biosensors achieve fluid stability with no loss in charge sensitivity , 2013, 71st Device Research Conference.

[29]  S. Martinoia,et al.  A behavioral macromodel of the ISFET in SPICE , 2000 .

[30]  Babak Ziaie,et al.  Diaper-embedded urinary tract infection monitoring system powered by a urine-powered battery , 2015, 2015 IEEE Biomedical Circuits and Systems Conference (BioCAS).