Comparison Between Spectral-Domain and Swept-Source Optical Coherence Tomography Angiographic Imaging of Choroidal Neovascularization

Purpose The purpose of this study was to compare imaging of choroidal neovascularization (CNV) using swept-source (SS) and spectral-domain (SD) optical coherence tomography angiography (OCTA). Methods Optical coherence tomography angiography was performed using a 100-kHz SS-OCT instrument and a 68-kHz SD-OCTA instrument (Carl Zeiss Meditec, Inc.). Both 3 × 3- and 6 × 6-mm2 scans were obtained on both instruments. The 3 × 3-mm2 SS-OCTA scans consisted of 300 A-scans per B-scan at 300 B-scan positions, and the SD-OCTA scans consisted of 245 A-scans at 245 B-scan positions. The 6 × 6-mm2 SS-OCTA scans consisted of 420 A-scans per B-scan at 420 B-scan positions, and the SD-OCTA scans consisted of 350 A-scans and 350 B-scan positions. B-scans were repeated four times at each position in the 3 × 3-mm2 scans and twice in the 6 × 6-mm2 scans. Choroidal neovascularization was excluded if not fully contained within the 3 × 3-mm2 scans. The same algorithm was used to detect CNV on both instruments. Two graders outlined the CNV, and the lesion areas were compared between instruments. Results Twenty-seven consecutive eyes from 23 patients were analyzed. For the 3 × 3-mm2 scans, the mean lesion areas for the SS-OCTA and SD-OCTA instruments were 1.17 and 1.01 mm2, respectively (P = 0.047). For the 6 × 6-mm2 scans, the mean lesion areas for the SS-OCTA and SD-OCTA instruments were 1.24 and 0.74 mm2 (P = 0.003). Conclusions The areas of CNV tended to be larger when imaged with SS-OCTA than with SD-OCTA, and this difference was greater for the 6 × 6-mm2 scans.

[1]  Mayank Bansal,et al.  Optical Coherence Tomography Angiography of Type 1 Neovascularization in Age-Related Macular Degeneration. , 2015, American journal of ophthalmology.

[2]  Jay S Duker,et al.  Spectral-domain optical coherence tomography angiography of choroidal neovascularization. , 2015, Ophthalmology.

[3]  K Bailey Freund,et al.  OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY OF TYPE 3 NEOVASCULARIZATION SECONDARY TO AGE-RELATED MACULAR DEGENERATION , 2015, Retina.

[4]  D. Sarraf,et al.  Optical Coherence Tomography Angiography of Type 1 Neovascularization in Age-Related Macular Degeneration. , 2016, Developments in ophthalmology.

[5]  E. Souied,et al.  Optical Coherence Tomography Angiography Features of Type 3 Neovascularization in Age-Related Macular Degeneration. , 2016, Developments in ophthalmology.

[6]  Yves Rosseel,et al.  On the Definition of Signal-To-Noise Ratio and Contrast-To-Noise Ratio for fMRI Data , 2013, PloS one.

[7]  K Bailey Freund,et al.  A Comparison Between Optical Coherence Tomography Angiography and Fluorescein Angiography for the Imaging of Type 1 Neovascularization. , 2016, Investigative ophthalmology & visual science.

[8]  C. E. Veloso,et al.  Optical Coherence Tomography Angiography Imaging of Quiescent Choroidal Neovascularization in Age-Related Macular Degeneration. , 2015, Ophthalmic surgery, lasers & imaging retina.

[9]  Ruikang K. Wang,et al.  Projection artifact removal improves visualization and quantitation of macular neovascularization imaged by optical coherence tomography angiography. , 2017, Ophthalmology. Retina.

[10]  David Huang,et al.  DETECTION OF NONEXUDATIVE CHOROIDAL NEOVASCULARIZATION IN AGE-RELATED MACULAR DEGENERATION WITH OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY , 2015, Retina.

[11]  Ruikang K. Wang,et al.  Swept-source OCT angiography of the retinal vasculature using intensity differentiation-based optical microangiography algorithms. , 2014, Ophthalmic surgery, lasers & imaging retina.

[12]  Philip J. Rosenfeld,et al.  Optical Coherence Tomography and the Development of Antiangiogenic Therapies in Neovascular Age-Related Macular Degeneration , 2016, Investigative ophthalmology & visual science.

[13]  E. Souied,et al.  Optical Coherence Tomography Angiography of Type 2 Neovascularization in Age-Related Macular Degeneration. , 2016, Developments in ophthalmology.

[14]  Ruikang K. Wang,et al.  SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY OF NEOVASCULAR MACULAR TELANGIECTASIA TYPE 2 , 2015, Retina.

[15]  J. Duker,et al.  Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second. , 2010, Optics express.

[16]  S. Sadda,et al.  Methodological remarks concerning the recent meta-analysis on the effect of intravitral bevacizumab in central serous chorioretinopathy , 2015, Eye.

[17]  Joachim Hornegger,et al.  Choroidal Neovascularization Analyzed on Ultrahigh-Speed Swept-Source Optical Coherence Tomography Angiography Compared to Spectral-Domain Optical Coherence Tomography Angiography. , 2016, American journal of ophthalmology-glaucoma.

[18]  Ruikang K. Wang,et al.  Original articleOptical Coherence Tomography Angiography of Asymptomatic Neovascularization in Intermediate Age-Related Macular Degeneration , 2016 .

[19]  Ruikang K. Wang,et al.  User-guided segmentation for volumetric retinal optical coherence tomography images. , 2014, Journal of biomedical optics.

[20]  Ruikang K. Wang,et al.  Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography. , 2015, Biomedical optics express.