Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances

Reactive tissue encapsulation of chronically implanted microelectrode probes can preclude long-term recording of extracellular action potentials. We investigated an intervention strategy for functionally encapsulated microelectrode sites. This method, known as "rejuvenation," involved applying a +1.5 V dc bias to an iridium site for 4 s. Previous studies have demonstrated that rejuvenation resulted in higher signal-to-noise ratios (SNRs) by decreasing noise levels, and reduced 1-kHz site impedances by decreasing the tissue interface resistances. In this study, we have investigated: 1) the duration of a single-voltage bias session and 2) the efficacy of multiple sessions. These questions were addressed through electrophysiological recordings, cyclic voltammetry, and modeling the electrode-tissue interface via an equivalent circuit model fit to impedance spectroscopy data. In the six implants studied, we found SNRs improved for 1-7 days with a peak typically occurring within 24 h of the voltage bias. Root-mean square (RMS) noise of the extracellular recordings decreased for 1-2 days, which paralleled a similar decrease in the adsorbed tissue resistance (R/sub en/) from the model. Implants whose SNR effects lasted more than a day showed stabilized reductions in the extracellular tissue resistance (R/sub ex/) and cellular membrane area (A/sub m/). Subsequent stimulus sessions were found to drop neural tissue parameters consistently to levels observed immediately after surgery. In most cases, these changes did parallel an improvement in SNR. These findings suggest that rejuvenation may be a useful intervention strategy to prolong the lifetime of chronically implanted microelectrodes.

[1]  D. Edell,et al.  Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex , 1992, IEEE Transactions on Biomedical Engineering.

[2]  Scott T. Retterer,et al.  Model neural prostheses with integrated microfluidics: a potential intervention strategy for controlling reactive cell and tissue responses , 2004, IEEE Transactions on Biomedical Engineering.

[3]  K. Wise,et al.  Silicon ribbon cables for chronically implantable microelectrode arrays , 1994, IEEE Transactions on Biomedical Engineering.

[4]  James D. Weiland,et al.  Chronic neural stimulation with thin-film, iridium oxide electrodes , 2000, IEEE Trans. Biomed. Eng..

[5]  David J. Anderson,et al.  Use of multichannel recording electrodes and independent component analysis for target localization in deep brain structures , 2003, First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings..

[6]  X Liu,et al.  Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[7]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[8]  E. McAdams,et al.  The linear and non-linear electrical properties of the electrode-electrolyte interface , 1995 .

[9]  P. Kennedy The cone electrode: a long-term electrode that records from neurites grown onto its recording surface , 1989, Journal of Neuroscience Methods.

[10]  J. Csicsvari,et al.  Intracellular features predicted by extracellular recordings in the hippocampus in vivo. , 2000, Journal of neurophysiology.

[11]  D. Szarowski,et al.  Brain responses to micro-machined silicon devices , 2003, Brain Research.

[12]  P. Pickup,et al.  A MODEL FOR ANODIC HYDROUS OXIDE GROWTH AT IRIDIUM , 1987 .

[13]  R. J. Vetter,et al.  Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  R. Normann,et al.  Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex , 1998, Journal of Neuroscience Methods.

[15]  Suzanne S. Stensaas,et al.  Histopathological evaluation of materials implanted in the cerebral cortex , 1978, Acta Neuropathologica.

[16]  W. L. C. Rutten,et al.  Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy , 1998, Medical and Biological Engineering and Computing.

[17]  D. Szarowski,et al.  Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.

[18]  Patrick A Tresco,et al.  Chronic response of adult rat brain tissue to implants anchored to the skull. , 2004, Biomaterials.

[19]  S. Retterer,et al.  Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[20]  R. Bellamkonda,et al.  Stabilizing electrode-host interfaces: a tissue engineering approach. , 2001, Journal of rehabilitation research and development.

[21]  D. Kipke,et al.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. , 1999, Brain research. Brain research protocols.

[22]  Daryl R. Kipke,et al.  Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes , 2006, IEEE Transactions on Biomedical Engineering.

[23]  R. Normann,et al.  A method for pneumatically inserting an array of penetrating electrodes into cortical tissue , 2006, Annals of Biomedical Engineering.

[24]  W. Grill,et al.  Electrical properties of implant encapsulation tissue , 2006, Annals of Biomedical Engineering.

[25]  J. Hetke,et al.  Surface modification of neural recording electrodes with conducting polymer/biomolecule blends. , 2001, Journal of biomedical materials research.

[26]  S S Stensaas,et al.  The reaction of the cerebral cortex to chronically implanted plastic needles. , 1976, Acta neuropathologica.

[27]  David C. Martin,et al.  A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex , 2005, Journal of neural engineering.

[28]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[29]  Richard B. Stein,et al.  Impedance Properties of Metal Electrodes for Chronic Recording from Mammalian Nerves , 1978, IEEE Transactions on Biomedical Engineering.

[30]  Jerald D. Kralik,et al.  Chronic, multisite, multielectrode recordings in macaque monkeys , 2003, Proceedings of the National Academy of Sciences of the United States of America.