A rapid cIEF-ESI-MS/MS method for host cell protein analysis of a recombinant human monoclonal antibody.

A rapid and reproducible system that couples capillary isoelectric focusing to a high-resolution mass spectrometer was developed for on-line analysis and identification of protein digests. Magnetic microsphere-based immobilized trypsin was used for protein digestion to reduce the digestion time to 10 min, with a total analysis time of 4h. A three-protein-mixture (myoglobin, BSA, cytochrome c) with a molarity ratio of 1:10:50 was successfully digested and identified. This system was also used to analyze host cell protein impurities in a recombinant humanized monoclonal antibody product in which the sample was product-depleted using affinity capture on protein A/protein L columns prior to analysis. A database search identified 37 host cell proteins with peptide and protein identity probability greater than 0.9.

[1]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[2]  J. van der Greef,et al.  Capillary isoelectric focusing‐mass spectrometry for shotgun approach in proteomics , 2004, Electrophoresis.

[3]  G. Anderson,et al.  High-efficiency capillary isoelectric focusing of peptides. , 2000, Analytical chemistry.

[4]  M. Hayes,et al.  Examining serum amyloid P component microheterogeneity using capillary isoelectric focusing and MALDI‐MS , 2011, Proteomics.

[5]  C. Smales,et al.  Host cell protein dynamics in the supernatant of a mAb producing CHO cell line , 2012, Biotechnology and bioengineering.

[6]  Cheng S. Lee,et al.  Capillary isoelectric focusing-electrospray mass spectrometry for protein analysis , 1995 .

[7]  F. Zhou,et al.  Intact protein profiling of Chlorobium tepidum by capillary isoelectric focusing, reversed-phase liquid chromatography, and mass spectrometry. , 2007, Analytical Chemistry.

[8]  N. Dovichi,et al.  High efficiency and quantitatively reproducible protein digestion by trypsin-immobilized magnetic microspheres. , 2012, Journal of chromatography. A.

[9]  A. Hunter,et al.  Host cell proteins in biologics development: Identification, quantitation and risk assessment , 2009, Biotechnology and bioengineering.

[10]  N. Dovichi,et al.  Capillary isoelectric focusing with pH 9.7 cathode for the analysis of gastric biopsies , 2011, Analytical and bioanalytical chemistry.

[11]  Jane A Dickerson,et al.  Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system , 2010, Analytical and bioanalytical chemistry.

[12]  N. Dovichi,et al.  Simplified capillary electrophoresis nanospray sheath-flow interface for high efficiency and sensitive peptide analysis. , 2010, Rapid communications in mass spectrometry : RCM.

[13]  Edwin D. Mares,et al.  On S , 1994, Stud Logica.

[14]  L. Zhang,et al.  Macroporous polyacrylamide‐based monolithic column with immobilized pH gradient for protein analysis , 2006, Electrophoresis.

[15]  A. Chen,et al.  Carrier-free zone electrophoresis, displacement electrophoresis and isoelectric focusing in a high-performance electrophoresis apparatus. , 1987, Journal of chromatography.

[16]  K. Champion,et al.  Proteomic studies support the use of multi‐product immunoassays to monitor host cell protein impurities , 2006, Proteomics.

[17]  Jane A. Dickerson,et al.  Femtomolar concentration detection limit and zeptomole mass detection limit for protein separation by capillary isoelectric focusing and laser-induced fluorescence detection. , 2009, Analytical chemistry.

[18]  Jane A Dickerson,et al.  Attomole protein analysis by CIEF with LIF detection , 2009, Electrophoresis.

[19]  G. D. de Jong,et al.  Development and characterization of cIEF‐MALDI‐TOF MS for protein analysis , 2009, Electrophoresis.

[20]  Hideo Yukinaga,et al.  On-line capillary isoelectric focusing-mass spectrometry for quantitative analysis of peptides and proteins. , 2005, Journal of pharmaceutical and biomedical analysis.

[21]  A replaceable microreactor for on-line protein digestion in a two-dimensional capillary electrophoresis system with tandem mass spectrometry detection. , 2011, Journal of chromatography. A.

[22]  J. van der Greef,et al.  Optimization of protein identification from digests as analyzed by capillary isoelectric focusing-mass spectrometry. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[23]  L. Zhang,et al.  Preparation and application of monolithic columns with narrow immobilized pH gradients. , 2006, Talanta.

[24]  Niki S. C. Wong,et al.  2-D DIGE to expedite downstream process development for human monoclonal antibody purification. , 2009, Protein expression and purification.

[25]  G. Anderson,et al.  Probing proteomes using capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. , 1999, Analytical chemistry.

[26]  A. Varenne,et al.  Online CIEF‐ESI‐MS in glycerol–water media with a view to hydrophobic protein applications , 2009, Electrophoresis.