An Approach to an Inhibition Electronic Tongue to Detect On-Line Organophosphorus Insecticides Using a Computer Controlled Multi-Commuted Flow System

An approach to an inhibition bioelectronic tongue is presented. The work is focused on development of an automated flow system to carry out experimental assays, a custom potentiostat to measure the response from an enzymatic biosensor, and an inhibition protocol which allows on-line detections. A Multi-commuted Flow Analysis system (MCFA) was selected and developed to carry out assays with an improved inhibition method to detect the insecticides chlorpyrifos oxon (CPO), chlorfenvinfos (CFV) and azinphos methyl-oxon (AZMO). The system manifold comprised a peristaltic pump, a set of seven electronic valves controlled by a personal computer electronic interface and software based on LabView® to control the sample dilutions into the cell. The inhibition method consists in the injection of the insecticide when the enzyme activity has reached the plateau of the current; with this method the incubation time is avoided. A potentiostat was developed to measure the response from the enzymatic biosensor. Low limits of detection of 10 nM for CPO, CFV, and AZMO were achieved.

[1]  D A Armbruster,et al.  Limit of detection (LQD)/limit of quantitation (LOQ): comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused drugs. , 1994, Clinical chemistry.

[2]  K. Courtney,et al.  A new and rapid colorimetric determination of acetylcholinesterase activity. , 1961, Biochemical pharmacology.

[3]  Jaromir Růžička,et al.  Flow injection analysis , 1981 .

[4]  Doris Schmitt-Landsiedel,et al.  Design of an integrated potentiostat circuit for CMOS bio sensor chips , 2003, Proceedings of the 2003 International Symposium on Circuits and Systems, 2003. ISCAS '03..

[5]  Jean-Louis Marty,et al.  Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides , 2002 .

[6]  J. Ruzicka,et al.  Sequential injection: a new concept for chemical sensors, process analysis and laboratory assays , 1990 .

[7]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[8]  Jean-Louis Marty,et al.  Twenty years research in cholinesterase biosensors: from basic research to practical applications. , 2006, Biomolecular engineering.

[9]  J. Marty,et al.  Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongue. , 2009, Biosensors & bioelectronics.

[10]  Wolfgang Schuhmann,et al.  On-Line Analysis of Mercury by Sequential Injection Stripping Analysis (SISA) Using a Chemically Modified Electrode , 2001 .

[11]  Gabriela Valdés-Ramírez,et al.  Sensitive amperometric biosensor for dichlorovos quantification: Application to detection of residues on apple skin. , 2008, Talanta.

[12]  Gert Cauwenberghs,et al.  VLSI potentiostat array for distributed electrochemical neural recording , 2002, 2002 IEEE International Symposium on Circuits and Systems. Proceedings (Cat. No.02CH37353).

[13]  Antonio Ruiz-Medina,et al.  Multicommutation in Flow Systems: A Useful Tool for Pharmaceutical and Clinical Analysis , 2010 .

[14]  Tse-Chuan Chou,et al.  A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprinting. , 2007, Biosensors & bioelectronics.

[15]  Matthew D. Steinberg,et al.  A micropower amperometric potentiostat , 2004 .

[16]  Robin F. B. Turner,et al.  A CMOS potentiostat for amperometric chemical sensors , 1987 .

[17]  J. P. Bobis,et al.  A potentiostat based on a voltage-controlled current source for use with amperometric gas sensors , 1991, [1991] Conference Record. IEEE Instrumentation and Measurement Technology Conference.

[18]  J. Marty,et al.  Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin , 2002, Analytical and bioanalytical chemistry.

[19]  Jean-Louis Marty,et al.  Enzyme immobilization procedures on screen-printed electrodes used for the detection of anticholinesterase pesticides Comparative study , 2004 .

[20]  M. Valle Electronic Tongues Employing Electrochemical Sensors , 2010 .

[21]  R. Duggleby,et al.  Analysis of kinetic data for irreversible enzyme inhibition. , 1989, The Biochemical journal.

[22]  Claire E Lenehan,et al.  Sequential injection analysis. , 2002, The Analyst.

[23]  Jean-Louis Marty,et al.  Highly sensitive detection of organophosphorus insecticides using magnetic microbeads and genetically engineered acetylcholinesterase. , 2007, Biosensors & bioelectronics.

[24]  Manuel Miró,et al.  How flow-injection analysis (FIA) over the past 25 years has changed our way of performing chemical analyses , 2007 .

[25]  Jean-Louis Marty,et al.  Electronic Tongue Using an Enzyme Inhibition Biosensor Array for the Resolution of Pesticide Mixtures , 2008 .

[26]  J. Ruzicka,et al.  Flow injection analyses , 1975 .

[27]  S. Higson,et al.  Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides. , 2005, Biosensors & bioelectronics.

[28]  Silvana Andreescu,et al.  Trends in Flow-based Biosensing Systems for Pesticide Assessment , 2006, Sensors (Basel, Switzerland).

[29]  R. Kakerow,et al.  Low-power Single-chip CMOS Potentiostat , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[30]  Danila Moscone,et al.  Biosensors based on cholinesterase inhibition for insecticides, nerve agents and aflatoxin B1 detection (review) , 2010 .

[31]  C. Tsou,et al.  Determination of the rate constant of enzyme modification by measuring the substrate reaction in the presence of the modifier. , 1982, Biochemistry.

[32]  Jaromir Ruzicka,et al.  Retro-review of flow-injection analysis , 2008 .