Assessment of Dry Epidermal Electrodes for Long-Term Electromyography Measurements

Commercially available electrodes can only provide quality surface electromyography (sEMG) measurements for a limited duration due to user discomfort and signal degradation, but in many applications, collecting sEMG data for a full day or longer is desirable to enhance clinical care. Few studies for long-term sEMG have assessed signal quality of electrodes using clinically relevant tests. The goal of this research was to evaluate flexible, gold-based epidermal sensor system (ESS) electrodes for long-term sEMG recordings. We collected sEMG and impedance data from eight subjects from ESS and standard clinical electrodes on upper extremity muscles during maximum voluntary isometric contraction tests, dynamic range of motion tests, the Jebsen Taylor Hand Function Test, and the Box & Block Test. Four additional subjects were recruited to test the stability of ESS signals over four days. Signals from the ESS and traditional electrodes were strongly correlated across tasks. Measures of signal quality, such as signal-to-noise ratio and signal-to-motion ratio, were also similar for both electrodes. Over the four-day trial, no significant decrease in signal quality was observed in the ESS electrodes, suggesting that thin, flexible electrodes may provide a robust tool that does not inhibit movement or irritate the skin for long-term measurements of muscle activity in rehabilitation and other applications.

[1]  Stacie A. Chvatal,et al.  Common muscle synergies for balance and walking , 2013, Front. Comput. Neurosci..

[2]  Raeed H. Chowdhury,et al.  Epidermal Electronics , 2011, Science.

[3]  Jeonghyun Kim,et al.  An Epidermal Stimulation and Sensing Platform for Sensorimotor Prosthetic Control, Management of Lower Back Exertion, and Electrical Muscle Activation , 2016, Advanced materials.

[4]  Vladimir Medved,et al.  Standards for Reporting EMG Data , 2000, Journal of Electromyography and Kinesiology.

[5]  David Rand,et al.  Temporary-tattoo for long-term high fidelity biopotential recordings , 2016, Scientific Reports.

[6]  Desney S. Tan,et al.  Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces , 2008, CHI.

[7]  A. Chan,et al.  Surface Electromyographic Signals Using Dry Electrodes , 2010, IEEE Transactions on Instrumentation and Measurement.

[8]  Anas Albulbul,et al.  Evaluating Major Electrode Types for Idle Biological Signal Measurements for Modern Medical Technology , 2016, Bioengineering.

[9]  Mathieu Nancel,et al.  Myopoint: Pointing and Clicking Using Forearm Mounted Electromyography and Inertial Motion Sensors , 2015, CHI.

[10]  Katherine M Steele,et al.  Muscle recruitment and coordination during upper-extremity functional tests. , 2018, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[11]  Jacques Duchateau,et al.  Physiology of Muscle Activation and Force Generation , 2016 .

[12]  A. Gruetzmann,et al.  Novel dry electrodes for ECG monitoring , 2007, Physiological measurement.

[13]  Aiping Liu,et al.  A Novel Phonology- and Radical-Coded Chinese Sign Language Recognition Framework Using Accelerometer and Surface Electromyography Sensors , 2015, Sensors.

[14]  Terry K Koo,et al.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. , 2016, Journal Chiropractic Medicine.

[15]  Alessandro Chiolerio,et al.  Inkjet printed flexible electrodes for surface electromyography , 2015 .

[16]  João Marcelo X. N. Teixeira,et al.  Evaluating Sign Language Recognition Using the Myo Armband , 2016, 2016 XVIII Symposium on Virtual and Augmented Reality (SVR).

[17]  Ho Chit Siu,et al.  Implementation of a Surface Electromyography-Based Upper Extremity Exoskeleton Controller Using Learning from Demonstration , 2018, Sensors.

[18]  V. Mathiowetz,et al.  Adult norms for the Box and Block Test of manual dexterity. , 1985, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[19]  K. Park,et al.  Flexible polymeric dry electrodes for the long-term monitoring of ECG , 2008 .

[20]  Sarah Westcott McCoy,et al.  Reliability and comparison of electromyographic and kinetic measurements during a standing reach task in children with and without cerebral palsy. , 2008, Gait & posture.

[21]  Marc W Slutzky,et al.  Reducing Abnormal Muscle Coactivation After Stroke Using a Myoelectric-Computer Interface , 2014, Neurorehabilitation and neural repair.

[22]  R Merletti,et al.  A new method to assess skin treatments for lowering the impedance and noise of individual gelled Ag-AgCl electrodes. , 2014, Physiological measurement.

[23]  A. Petrėnas,et al.  A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings. , 2011, Journal of electrocardiology.

[24]  Yunhui Liu,et al.  Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor , 2012, Sensors.

[25]  Carlo J. De Luca,et al.  The Use of Surface Electromyography in Biomechanics , 1997 .

[26]  James J. S. Norton,et al.  Materials and Optimized Designs for Human‐Machine Interfaces Via Epidermal Electronics , 2013, Advanced materials.

[27]  L. Kirkup,et al.  A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.

[28]  J. Basmajian Muscles Alive—their functions revealed by electromyography , 1963 .

[29]  Karthik Dinesh,et al.  Multiple Wearable Sensors in Parkinson and Huntington Disease Individuals: A Pilot Study in Clinic and at Home , 2017, Digital Biomarkers.

[30]  A E Grassino,et al.  Automatic assessment of electromyogram quality. , 1995, Journal of applied physiology.

[31]  Hugo Hugo Posada-Quintero Posada-Quintero,et al.  Assessment of Carbon/Salt/Adhesive Electrodes for Surface Electromyography Measurements , 2016, IEEE Journal of Translational Engineering in Health and Medicine.

[32]  Deji Akinwande,et al.  Graphene Electronic Tattoo Sensors. , 2017, ACS nano.

[33]  Kiyoshi Kotani,et al.  A Novel Unsupervised Adaptive Learning Method for Long-Term Electromyography (EMG) Pattern Recognition , 2017, Sensors.

[34]  F. Nouri,et al.  The effectiveness of EMG biofeedback in the treatment of arm function after stroke. , 1989, International disability studies.

[35]  R. H. Jebsen,et al.  An objective and standardized test of hand function. , 1969, Archives of physical medicine and rehabilitation.

[36]  Phornphop Naiyanetr,et al.  Sign language-Thai alphabet conversion based on Electromyogram (EMG) , 2014, The 7th 2014 Biomedical Engineering International Conference.

[37]  Alexander Refsum Jensenius,et al.  Mumyo - evaluating and exploring the myo armband for musical interaction , 2015, NIME.

[38]  Gaurav Sharma,et al.  Signal analysis for detecting motor symptoms in Parkinson's and Huntington's disease using multiple body-affixed sensors: A pilot study , 2016, 2016 IEEE Western New York Image and Signal Processing Workshop (WNYISPW).

[39]  Mohamed Abdur Rahman,et al.  A Multi-sensory Gesture-Based Login Environment , 2015, ACM Multimedia.

[40]  Yao-Feng Chang,et al.  “Cut‐and‐Paste” Manufacture of Multiparametric Epidermal Sensor Systems , 2015, Advanced materials.

[41]  Zhaopeng Li,et al.  Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring , 2016, Sensors.